SunStar CK18T-4-LP Скачать руководство пользователя страница 15

 

-14- 

HOW TO ORDER REPAIR PARTS …  

 

All parts listed in the Parts List have a Part Number.  When ordering parts, first obtain the Model Number from the nameplate on your equipment.  Next, 
determine the Part Number 

(not the Index Number)

 and the Description of each part from the following appropriate illustration and list.  Be sure to give all this 

information. 

 

Heater Model Number:

 

 

Part Description:

 

 

Heater Serial Number:

 

 

Kind of Gas:

 

 

Part Number:

 

 

(Propane or Natural) 

 

 

Do not order bolts, screws, washers or nuts.  They are standard hardware items and can be purchased at any local hardware store.  Order parts from your local 
dealer or through

 Gas-Fired Products, Inc.

  Shipments of parts are contingent upon strikes, fires, and all other causes beyond our control. 

 

REPAIR PARTS 

MODEL 

SC18T-1–LP 

MODEL 

SC30T-1–LP 

MODEL 

SC18T-1–NG 

MODEL 

SC30T-1–NG 

Propane Gas

 

Propane Gas

 

Natural Gas

 

Natural Gas

 

Index 

Number 

Part Number

 

DESCRIPTION 

43574080  43574080  

Burner 

– 

Three 

Plates 

43585720  43585720  

Tubing 

to 

First and Second Plate 

2a 

43585410 

 

 

43585410 

Tubing T to Third Plate 

43585660 

 

 

43585670 

Tubing Valve to ODS 

43585071 

 

43585071 

43585110 

Tubing Valve to Pilot Regulator 

43576090  43576010 

43576010 

Pilot 

Regulator 

 

 

43590050 

43590050 

Regulator Inlet Adapter 

 

 

43585380 

43585670 

Pilot Tubing Regulator to Pilot 

43585690 

 

43585690 

 

Tubing Valve to T Connector 

43575150  43575160  

Double 

Plate 

Orifice 

10 

43575140  43575030  

Single 

Plate 

Orifice 

11 

43591030  43591030  

Connector 

12 

43596000 43596000 43596000 43596000 

Thermostatic 

Valve 

13 

43590020 43590020 43590020 43590020 

Adaptor 

14 

43585700 

43585700 

43585700 

43585700 

Tubing Valve To T Connector 

15 

43573050 43573050 43573050 43573050 

Piezo 

Ignitor 

16 

 

43585700 

 

 

Tubing Valve to ODS 

17 

 43574050  43574050 

Burner 

– 

Five 

Plates 

18 

43597170 43597170 43597170 43597170 

ODS 

Screw 

19 

 43575140  43575030 

Single 

Plate 

Orifice 

20 

43584040 43584040 43584110 43584030 

ODS 

Assembly 

21 

43585710 43585710 43585710 43585710 

Tubing 

Second 

Plate 

22 

43585720 43585720 43585720 43585720 

Tubing 

First 

Plate 

23 

 43585180  43585180 

Tubing 

Third 

Plate 

24 

 43585730  43585730 

Tubing 

Fourth 

Plate 

25 

 43591020  43591020 

Connector 

26 

43601070 43601070 43601070 43601070 

Thermostatic 

Bulb 

Rear 

Support 

27 

 43585740  43585740 

Tubing 

Fifth 

Plate 

28 

43601090 43601090 43601090 43601090 

Thermostatic 

Bulb 

First 

Support 

29 

43585071 

43585760 

43585071 

43585760 

Tubing Input Regulator to Valve 

30 

43600010 43600010 43600010 43600010 

Regulator 

Support 

31 

43601100 

43601100 

43601100 

43601100 

Gas Valve Support (not shown) 

32 

43576090 43576090 43576120 43576120 

Input 

Regulator 

33 

43602040 43602040 43602040 43602040 

Trim 

Slide 

33a 

43602030 43602030 43602030 43602030 

Switch 

Cover 

34 43597160 

43597160

 

43597160

 

43597160

 

Screw 

35 

43126220 43126220 43126220 43126220 

Installation 

Operation 

Manual 

36 43597120 

43597120

 

43597120

 

43597120

 

Screw 

37 

43578210 43578230 43578210 43578230 

Heat 

Shield 

Top 

38 

43578240 43578220 43578240 43578220 

Heat 

Shield 

Bottom 

39 

43580400 43580410 43580400 43580410 

Casing, 

Rear 

40 

43597120 43597120 43597120 43597120 

Screw 

41 

43800050 43800050 43800050 43800050 

Rear 

Leg 

42 

43579280 43579290 43579280 43579290 

Screen 

43 

43580360 43580370 43580360 43580370 

Front 

Frame 

44 

43581130 43581140 43581130 43581140 

Safety 

Guard 

45 

43800030 43800030 43800030 43800030 

Front 

Leg 

 
 
 

Содержание CK18T-4-LP

Страница 1: ...ppliance CONSUMER Retain this manual for future reference This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to the section titled Combustion and ventilation air requirement Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other ...

Страница 2: ...should stay away to avoid burns or clothing ignition 3 Young children should be carefully supervised when they are in the room with the heater 4 Do not install this heater at altitudes above 5000 ft because shutdown of the heater by the ODS system may occur due to reduced oxygen levels at these altitudes 5 This appliance is only for use with the type of gas indicated on the nameplate THIS APPLIANC...

Страница 3: ...an unconfined space as a space whose volume is not less than 50 ft3 per 1 000 BTU Hr 4 8 m3 kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the space 20 WARNING If the area in which the heater may be operated is smaller than...

Страница 4: ..._ x 20 Btu hr ____________________ Btu hr STEP 3 Add the Btu hr inputs of all fuel burning appliances in this space NOTE DO NOT include Direct Vent gas appliances because these have sealed combustion systems that draw combustion air from outdoors Examples of appliances to consider include gas ranges gas water heaters gas logs kerosene heaters etc Proposed Vent Free Heater _________________________...

Страница 5: ... odorant in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If ...

Страница 6: ...rpeting tile or other floor covering When facing the front of the heater the clearance from any combustible materials must be a minimum of 13 from the left 13 from the right 36 from the top and 2 from the bottom Never install the heater in front of any flammable object especially do not place curtains furniture clothing or other flammable objects less than 36 from the front of the heater FLOOR MOU...

Страница 7: ...tion as indicated in Figure 2 1 2 Drill two 2 5 16 holes according to the dimensions shown on the upper corner of Figure 2 1 3 Drill another 5 16 hole on the wall stud for the U hook as shown in Figure 2 2 4 Screw in the three 3 plastic expansion anchors furnished with the unit as shown in Figure 2 1 5 Screw in the furnished screws through the anchors as shown in Figure 2 1 6 Connect the gas line ...

Страница 8: ...ply line shall be sized and installed to provide a sufficient supply of gas to meet the minimum demand of the heater without undue loss of pressure Typical Installation Supply Line Up to 20 000 Btu hr 3 8 or greater Up to 30 000 Btu hr 1 2 or greater 5 The sealant used on the threaded pipe joints of the gas pipe must be the specific type resistant to the action of Liquid Petroleum Gas Apply sealan...

Страница 9: ...the beginning of the heating season If your pilot will not stay lit try cleaning it Use a can of compressed air such as is used to clean a computer to blow dust out of the pilot assembly Sometimes just blowing air back through the pilot will get rid of the dirt If that fails to solve the problem remove the wire clip that holds the metal strip onto the pilot assembly Remove the cover and blow any d...

Страница 10: ... and rotate counterclockwise to P position 7 Depress control knob completely and without releasing knob press piezo igniter button repeatedly until pilot is lit 8 Continue depressing control knob for 30 seconds after pilot is lit before releasing If knob does not pop up when released stop and immediately call your service technician or gas supplier 9 Pilot should remain lit If the pilot will not s...

Страница 11: ...gas valve BURNER DOES NOT LIGHT Pilot stays lit Burner orifice clogged Burner orifices not correct size Extremely low inlet gas pressure Gas valve is defective Clean or replace orifices Replace with correct size Contact gas supplier Replace gas valve IMPROPER BURNER PATTERN Slight smoke or odor during initial operation Residues from manufacturing process or dust Problem will be eliminated after a ...

Страница 12: ... 1 LP Propane Gas SC18T 1 NG Natural Gas Models WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury ...

Страница 13: ...24 25 26 27 28 29 30 13 32 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury SC30T 1 LP Propane Gas SC30T 1 NG Natural Gas Models ...

Страница 14: ... 13 33 34 36 37 38 40 41 45 44 43 42 39 M ODELS SC18T 1 LP and SC30T 1 LP Propane Gas SC18T 1 NG and SC30T 1 NG Natural Gas ...

Страница 15: ...0 43590020 Adaptor 14 43585700 43585700 43585700 43585700 Tubing Valve To T Connector 15 43573050 43573050 43573050 43573050 Piezo Ignitor 16 43585700 Tubing Valve to ODS 17 43574050 43574050 Burner Five Plates 18 43597170 43597170 43597170 43597170 ODS Screw 19 43575140 43575030 Single Plate Orifice 20 43584040 43584040 43584110 43584030 ODS Assembly 21 43585710 43585710 43585710 43585710 Tubing ...

Страница 16: ...15 Manufactured for SUNSTAR HEATING PRODUCTS INC 306 West Tremont Avenue Charlotte NC 28203 4946 704 372 3486 ...

Отзывы: