SunStar CK18T-4-LP Скачать руководство пользователя страница 1

 

FORM 43126220 

 

July 09 

 

 

 

W A R N I N G 

 

Any change to this heater or its controls can be dangerous. 

 

For proper ventilation, provide a minimum fresh air opening of one square inch 
for every 1,000 BTU's of gas burner capacity.

 

INSTALLATION 

AND 

OWNER'S GUIDE 

 

 

Effective Date:   July 2009 

 

 

IMPORTANT: 

Owner please fill out and mail warranty card supplied with heater. 

 

Due to high temperatures, the appliance should be located 
out of traffic and away from furniture and draperies. 

 

Children and adults should be alerted to the hazard of high 
surface temperature and should be kept away to avoid 
burns or clothing ignition. 

 

Young children should be carefully supervised when they 
are in the same room with the appliance. 

 

Do not place clothing or other flammable material on or 
near the appliance. 

 

Installation and repair should be done by a qualified service 
person. 

 

The appliance should be inspected before use and at least 
annually by a qualified service person.  More frequent 
cleaning may be required due to excessive lint from 
carpeting, bedding material, etc.    It  is  imperative  that 
control compartments, burners, and circulating air 
passageways of the appliance be kept clean.

 

 
 

VENT-FREE 

ROOM HEATER 

 

Models: SC18T-1–NG/LP 
 SC30T-1–NG/LP

 

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference. 

This is an unvented gas fired heater.  It uses air 
(oxygen) from the room in which it is installed.  
Provisions for adequate combustion and 
ventilation air must be provided. Refer to the 
section titled “Combustion and ventilation air 
requirement”. 

 
 
 
 
 
 

Do not store or use gasoline or other flammable 
vapors and liquids in the vicinity of this or any 
other appliance. 

 

WHAT TO DO IF YOU SMELL GAS 

 

Do not try to light any appliance. 

 

Do not touch any electrical switch; do not use 
any telephone in your building. 

 

Immediately

 call your gas supplier from a 

neighbor's telephone.  Follow the gas 
supplier's instructions. 

 

If you cannot reach your gas supplier, call the 
fire department.  

 

Installation and service must be performed by a 
qualified installer, service agency or the gas 
supplier. 

WARNING:

  If the information in this manual 

is not followed exactly a fire or explosion may 
result causing property damage, personal injury 
or loss of life. 

This appliance may be installed in an aftermarket 
permanently located, manufactured (mobile) 
home, where not prohibited by local codes.   

 

This appliance is only for use with the type of gas 
indicated on the rating plate. This appliance is not 
convertible for use with other gases.

GENERAL INFORMATION  

This series is design certified by the CSA Laboratories as an 
Unvented Heater, and must be installed according to these 
instructions. 
This appliance is intended for supplemental heating. 

Содержание CK18T-4-LP

Страница 1: ...ppliance CONSUMER Retain this manual for future reference This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to the section titled Combustion and ventilation air requirement Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other ...

Страница 2: ...should stay away to avoid burns or clothing ignition 3 Young children should be carefully supervised when they are in the room with the heater 4 Do not install this heater at altitudes above 5000 ft because shutdown of the heater by the ODS system may occur due to reduced oxygen levels at these altitudes 5 This appliance is only for use with the type of gas indicated on the nameplate THIS APPLIANC...

Страница 3: ...an unconfined space as a space whose volume is not less than 50 ft3 per 1 000 BTU Hr 4 8 m3 kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the space 20 WARNING If the area in which the heater may be operated is smaller than...

Страница 4: ..._ x 20 Btu hr ____________________ Btu hr STEP 3 Add the Btu hr inputs of all fuel burning appliances in this space NOTE DO NOT include Direct Vent gas appliances because these have sealed combustion systems that draw combustion air from outdoors Examples of appliances to consider include gas ranges gas water heaters gas logs kerosene heaters etc Proposed Vent Free Heater _________________________...

Страница 5: ... odorant in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If ...

Страница 6: ...rpeting tile or other floor covering When facing the front of the heater the clearance from any combustible materials must be a minimum of 13 from the left 13 from the right 36 from the top and 2 from the bottom Never install the heater in front of any flammable object especially do not place curtains furniture clothing or other flammable objects less than 36 from the front of the heater FLOOR MOU...

Страница 7: ...tion as indicated in Figure 2 1 2 Drill two 2 5 16 holes according to the dimensions shown on the upper corner of Figure 2 1 3 Drill another 5 16 hole on the wall stud for the U hook as shown in Figure 2 2 4 Screw in the three 3 plastic expansion anchors furnished with the unit as shown in Figure 2 1 5 Screw in the furnished screws through the anchors as shown in Figure 2 1 6 Connect the gas line ...

Страница 8: ...ply line shall be sized and installed to provide a sufficient supply of gas to meet the minimum demand of the heater without undue loss of pressure Typical Installation Supply Line Up to 20 000 Btu hr 3 8 or greater Up to 30 000 Btu hr 1 2 or greater 5 The sealant used on the threaded pipe joints of the gas pipe must be the specific type resistant to the action of Liquid Petroleum Gas Apply sealan...

Страница 9: ...the beginning of the heating season If your pilot will not stay lit try cleaning it Use a can of compressed air such as is used to clean a computer to blow dust out of the pilot assembly Sometimes just blowing air back through the pilot will get rid of the dirt If that fails to solve the problem remove the wire clip that holds the metal strip onto the pilot assembly Remove the cover and blow any d...

Страница 10: ... and rotate counterclockwise to P position 7 Depress control knob completely and without releasing knob press piezo igniter button repeatedly until pilot is lit 8 Continue depressing control knob for 30 seconds after pilot is lit before releasing If knob does not pop up when released stop and immediately call your service technician or gas supplier 9 Pilot should remain lit If the pilot will not s...

Страница 11: ...gas valve BURNER DOES NOT LIGHT Pilot stays lit Burner orifice clogged Burner orifices not correct size Extremely low inlet gas pressure Gas valve is defective Clean or replace orifices Replace with correct size Contact gas supplier Replace gas valve IMPROPER BURNER PATTERN Slight smoke or odor during initial operation Residues from manufacturing process or dust Problem will be eliminated after a ...

Страница 12: ... 1 LP Propane Gas SC18T 1 NG Natural Gas Models WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury ...

Страница 13: ...24 25 26 27 28 29 30 13 32 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury SC30T 1 LP Propane Gas SC30T 1 NG Natural Gas Models ...

Страница 14: ... 13 33 34 36 37 38 40 41 45 44 43 42 39 M ODELS SC18T 1 LP and SC30T 1 LP Propane Gas SC18T 1 NG and SC30T 1 NG Natural Gas ...

Страница 15: ...0 43590020 Adaptor 14 43585700 43585700 43585700 43585700 Tubing Valve To T Connector 15 43573050 43573050 43573050 43573050 Piezo Ignitor 16 43585700 Tubing Valve to ODS 17 43574050 43574050 Burner Five Plates 18 43597170 43597170 43597170 43597170 ODS Screw 19 43575140 43575030 Single Plate Orifice 20 43584040 43584040 43584110 43584030 ODS Assembly 21 43585710 43585710 43585710 43585710 Tubing ...

Страница 16: ...15 Manufactured for SUNSTAR HEATING PRODUCTS INC 306 West Tremont Avenue Charlotte NC 28203 4946 704 372 3486 ...