7-2
If the machine operating system is not in the memory, or if and keys were pressed at the same time,
the system installation program will appear (see below).
The system installation program includes the following sub-menus.
Ex) Copying the Vx.1 operating system currently stored in the memory onto the DISK 1 and the Vx.2 program in the
DISK 2 onto the memory.
Press and at the
same time when
“
===SWF-EMB
Vx.xx===
”
appears on the screen.
�
Inset DISK 1 into the drive and move
the cursor to
“
2. VERSION
BACKUP
”
(1) VERSION INSTALL: installs or upgrades the machine operating programs.
(2) VERSION BACKUP: copies the machine operating program in the memory onto a disk.
(3) ENCODER SETTING: sets the main shaft encoder.
(4) C/C SETTING: selects signals for the needle bar position.
(5) X ORIGIN SETTING: checks origin on the X-axis during machine inspection.
(6) Y ORIGIN SETTING: checks origin on the Y-axis during machine inspection.
(7) WIPER RET SENSOR: checks wiper solenoid return sensor during machine inspection.
(8) START/STOP CHECK: checks START/STOP buttons during machine inspection.
(9) SETTING DEFAULT: turns the machine set-up and EMB set-up to default values.
(10) CURRENT SETTING: sets the voltage of X-Y driver during machine operation.
(11) GEAR RATIO CHECK: selects pulley ratio of the main shaft.
(12) MACHINE SETTING: selects the type of machine.
(13) EXIT: goes back to the machine operating program.
1. VERSION INSTALL
2. VERSION BACKUP
3. ENCODER SETTING
4. C/C SETTING
= I N S T A L L P R O G R A M =
[Machine Information]
[Menu]
1. VERSION INSTALL
2. VERSION BACKUP
3. ENCODER SETTING
4. C/C SETTING