12-2
Error Type
Cause
①
Incorrect position of needle
stop
②
Failure to sense signals for
needle position or 1 rotation
③
Incorrect position of needle
bar
④
Incorrect position of take-up
lever
⑤
Failure in fuse for color
change motor
Bad connection
Inspection & Repair
Refer to user
’
s manual
Run manual color change and
check if signal lamps (needle
set lamp & needle position
lamp) blinks at correct needle
position. Adjust the half-turn
film.
Set it to the correct position
Adjust so take-up lever is in
line with other levers in stop
position (upper shaft
angle:100
�
)
Change fuse F3 in joint board
or check connection
Set main shaft angle back at
100
�
, if you manually moved
it for cleaning, inspection or
repair.
Ref. 11-8, 11-7)
Unscrew the lever and
adjust so it is in line with the
others on the guide rail.
※
Check fuse spec.
Ref. 9-1, 9-1)
Reference
Bad Color
Change
take-up lever
screw
take-up
lever