background image

GROUND WIRE ATTACHMENT lN

RECESSED HOUSINGS

NOTE: 

Green ground wire must be securely installed

to the housing. Three connection methods shown below.

1. 

For ground connection from LED module to housing,

    use provided green ground wire.

2.

 Connect other end of green ground wire to housing.

    ● Use supplied #8 screw in existing hole (Fig. 9).

MODULE lNSTALLATION INTO E26

EDISON SCREWBASE RECESSED

HOUSINGS

NOTE: 

Confirm luminiare is compatible with DSK6

module series. A listing of the most common housings is

provided in the HOUSINGS section of these instructions.

1. 

Remove mounting bracket and plate from inside

    existing recessed housing (if installed).

1a. 

Ensure bottom edge of housing is flush with ceiling

    Adjust height if necessary to ensure a tight finish.

2.

 Release socket from the housing plate (if installed).

3. 

Screw Edison base adapter into existing Edison base

    socket in housing (Fig. 10).

4.

 Install connector "I" (supplied) onto stripped wire

    ends of supply wire adapter (Fig 11a). Be sure to

    align black wire with black strip on connector. Push

    wires into connector until firmly seated (Fig. 11b). Pull

    lightly on wires to confirm they are locked into the

    connector.

5.

 Plug orange connector on DSK6 LED module series

    into the orange connector on supply wire adapter

    (Fig. 12).

6. 

Squeeze the torsion springs together as shown and

    install into torsion spring brackets inside recessed

    housing (Fig. 13 and 14).

7. 

Carefully route wires into fixture and push LED

    module up flush to ceiling surface.

REPLACING DSK6

Recessed Housing

1. 

With fingertips, pull down firmly on trim ring until

    module is .removed from the housing.

2.

 Squeeze torsion springs together to remove LED

    module. 

3. 

Disconnect LED module wiring from recessed

    housing. (LED connector).

Electrical Junction Box

1. 

Rotate trim ring counter clockwise and then lower

    module.

2.

 Disconnect wiring.

Fig.9

Ceiling thickness adjustment slot

(one of three slots inside housing)

(View from inside the housing)

Ground wire

Fig.10

E26 Edison screw base

Fig.13

Fig.12

Fig.14

Torsion Spring Brackets

Fig.11b

Fig.11a

RIS0233

4/4

This LED fixture uses dimmable driver (#QTDOB12W-74RD-120D-XXX).

Please refer to the Luminance website luminance.us.com for list of compatible drivers.

If you want to dim the fixture,the applied dimmer which is made from 

Leviton#IPI06&6631 OR Lutron#DVCL-153-PL&S-600P

Luminance

1945 S Tubeway Ave Commerce CA 90040

Tel#800-777-4440

WARNNING: 

For WET locatin applications, after fixture is 

installed on ceiling, put silicone glue to seal the 

gap between fixture and ceiling.