background image

10

3020

2618

2016

Part Number Part Description

MM MD MH MM MD MH

M

H

G01A-332

Thermpile 32"

x

x

x

x

x

1970-024

Thermcouple 24"

x

x

x

x

x

9A8A38A9A

Millivolt Gas Valve

x

x

x

x

x

764-742

Manual Gas Valve

x

x

x

x

1F78-151

Wall Thermostat

x

x

x

x

x

3L11-350

H Limit Switch

x

x

x

3L11-180

H Limit Switch

x

x

x

Bur-OR-25

1/4" Burner Orifice 

NG#43 LP#54

x         x

BUR-OR-12

1/8” Burner Orifice 

NG#37 LP#51

x

x

x

x

J999MDW

Pilot Single

x

x

x

x

J998-MDW

Pilot Double

x

x

x

x

PI-OR4212

Pilot Orifice-LP

PI-OR 7211

Pilot Orifice NG

O710-502

Hydraulic Gas Valve LP

x

x

x

0710-501

Hydraulic Gas Valve NG

x

x

x

IMBU 6

6" Burner Import

USBU 6

6" Burner US

x

x

x

x

x

BU-Sleeve

Burner Sleeves

x

x

x

PI-Tube

Pilot Tubing 22"

Flex-3

3/8-3-Flex Connector

x

x

x

x

x

x

x

x

Flex-8

3/8-8-Flex Connector

x

x

BUR-BR

Burner Bracket

Specify Model

PIL-PI

Pilot Plug

x

x

x

x

PIL-BR

Pilot Bracket

x

x

x

MA020676R Piezo Ignitor

x

x

x

x

x

x

x

x

H06F-24

Junction Block Thermocouple

x

x

x

Con-KN

Control Knob

x

x

x

All parts ordered must include model and serial number, LP–NG and part needed, so we can 

send the right parts. Call your local dealer and/or installer for the proper replacement parts.

NG=Natural Gas

LP =Propane

Parts List

Use only replacement parts certified by Blu-Flame

Содержание 2016-M

Страница 1: ...WARNING Please read carefully before operating your SUNRISE ROOM HEATER Owner s Manual for ROOM HEATERS...

Страница 2: ...CONNECTION Install the fitting into the pilot gas tapping turning until finger tight Insert clean debarred tubing all the way through the fitting Holding the tubing securely slowly tighten the fittin...

Страница 3: ...temperature control knob to high counter clockwise Hold the red button down and push the piezo ignitor repeatedly until the pilot light stays lit approximately 30 seconds If the pilot light goes out r...

Страница 4: ...0 M 2618 M 2016 M 3020 M M 2618 M M Lighting and relighting procedures for all 2010 and later models 1 Light the left hand burner first facing the heater Turn the knob to pilot and push down Push the...

Страница 5: ...aterial to change to L P or natural gas operation as desired 6 Replace cap and tighten 7 Check outlet pressure with pressure gage at outlet pressure tap to determine if the gas valve is functioning wi...

Страница 6: ...er and air mixer Adjust air intake Call your service technician for assistance Q The thermostat doesn t light A See proper section on how to light the heater Hydraulic thermostat page 3 Millivolt page...

Страница 7: ...higher than the heater Hood should be 1 2 3 4 wider than heater on all four sides See diagram Overall Height Varies approx 60 12 3 8 19 5 21 2 x 10 Floor Joist Side View 12 x 14 Main Register Basement...

Страница 8: ...the room temperature at the selected temperature at the selected temperature until the next program period begins Then the thermostat will automatically revert to the program HOLD TEMPERATURE The ther...

Страница 9: ...t heating program period The start time is 6 00 AM and 70 is the programmed temperature this example reflects factory pre programming 3 Press or to change the displayed temperature to your selected te...

Страница 10: ...02 Hydraulic Gas Valve LP x x x 0710 501 Hydraulic Gas Valve NG x x x IMBU 6 6 Burner Import USBU 6 6 Burner US x x x x x BU Sleeve Burner Sleeves x x x PI Tube Pilot Tubing 22 Flex 3 3 8 3 Flex Conne...

Страница 11: ...11 Millivolt System Hydraulic System 32 1 30 1 31 1...

Страница 12: ..._____ ____ ____ 20___ _____________________________________________ ____ ____ 20___ _____________________________________________ ____ ____ 20___ _____________________________________________ ____ ___...

Отзывы: