Sunrise Telecoms SR101 PLUS Скачать руководство пользователя страница 8

 

Programming Table   Ver:1.03 

Connect a Single-Line Phone and 

hang up

Press and hold on [P] 

key then 

plug in power

   

 2 LED Blinking slowly. 

Lift handset

 (or press [HOOK] key if have).           

 2 LED keep light and waiting for a long Beep. 

Input security 

Password(

Default is 

1234)

               

 2 LED keep dark waiting for a long Beep.. 

Dial the

 ITEM and IMMEDIATELY the data

 which you want to store in. 

 

IF want to clear all data before programming please dial *0 and waiting for a long Beep 

ITEM

Description

 

Actual data

 

Digits

 

(Digit 1) 

1

st

 Prefix   

P: None 
1-#=prefix

 

(Digit 2) 

2

nd

 Prefix 

P: None 
1-#=prefix

 

(Digit 3) 

Total digits of prefix 
included 1

st

 & 2

nd  

Max. 8 digits

 

(Digit 4) 

Send just received 
prefix or not? 
1:yes  0:no

 

1

 

 

 
 
 

 

(Digit 5) 

Total digits of 
user’s password 
 
max. 8 digits 

(Digit 6) 

Send just 
received user’s 
password or not 
1:yes  0:no 

(Digit 7) 

Send stored user’s 
password to system 
or not? 
P= no,  1-*#=yes, 
also send this code 

(Digit 8) 

When to send stored 
user ‘s password? 
0: before send Item4 
1: before send Item5 
2: before send Item8 

 

2  First system’s 

Trigger code, 

should be international prefix e.g. 011 in USA. 

(Input * means accept any code, Input 0P means for tolling call)

 

 

3  First system’s 

Access No

.                                                   

/

Clear if access ISR

 

 

16 

4  First system’s 

PIN code

 and/or password.            

/

Clear if access ISR

   

16 

5  First system’s 

Destination prefix         

/

ISR access prefix

 e.g. 18XXX

 

 

16 

First system’s 

Backup access No.

 In case of unreachable.

 

 

16 

First system’s 

extra Trigger code. 

 e.g. 01*

 

 

8  First system’s 

Destination suffix.

 e.g. #

             /

Clear if access ISR

    

9  Security Password for entry programming mode. Dialer will auto-backup 

current password when set it. Next time you may use new or old password, if 
you want keep only one please set this twice. 

(please don't forget!)

  

IMPORTANT 

Fixed 4 
digits 

Exceptant code

. Per code add * to wait beep and input next code. 

e.g. 86*---84*---323*---673*--- ---(Waiting another beep to finish if no more)

 

 

4digits/ 
20 sets 

# (Digit 

1) 

 

DTMF duration time 

*

= 50mS, #=60mS

 

0= 70mS, 1=100mS   

2=150mS, 3=200mS 

(Digit 2) 

FLASH TIME 

1=100mS 

2=200mS 
3=300mS,... 

(Digit 3) 

Remote prog. 

0= Enable 

1= Disable 

(Digit 4) 

Waiting time to stop. 

Not divert call=1S 
Divert call=3S 
1=4S,2=3S,3=2S 

 4 

*

9

 

 

Prefix code when active Special function by dial * (see item *# digit 2)

  

** 

Pre-set user’s password for dialer to verify. Per password add * to wait beep 
and input next password. e.g. 123*---456*---323*---673*--- --- 

 4digits/ 

48 sets 

(Digit 1) 

Force pass Code 
 
E.g. # 

(Digit 2) 

Trigger code for 
active special 
function. 
E.g. * 

(Digit 3) 

Connect line and phone 
after all dialed? 

0=Yes 1=No 

#=yes, but wait #,A,B,C 

(Digit 4) 

Tone/Pulse dialing 
(Dial item 3 only) 

0=DTMF 

1=PULSE 

*

#

 

(Digit 5) 

Connect line and 
phone in standby 
mode? 

0=Yes  1=No 

(Digit 6) 

N/A 

(Digit 7) 

N/A 

(Digit8) 

N/A 

 8 

*27

  

First system’s

 2

nd

 extra Trigger code. 

e.g. 02*

 

 

*37

  

First system’s 

third Trigger code.

 

 

*47

  

(Digit 1)

 

Extra trigger check sequence 
0=Immediately after checked 
first item 2 
1=Checked every item 2 then 
check e

xtra trigger

 

(Digit 2)   

Time to release line 
when unreachable 
 

No=0.8S 

1=1S, 2=1.2S, 3=1.4S... 

(Digit 3) 

N/A

 

(Digit 4) 

N/A

 

 

 

1=When extra trigger (item 7) set 01*, but have normal trigger (item 2) set to 011.   Code confusing 

 

0=When extra trigger (item 7) set 01*, but have normal trigger (item 2) set to 0P.  Code confusing

 

Содержание SR101 PLUS

Страница 1: ...01 SR101 PLUS 1PCs 2 wires line cord 1PCs DC 24V 150mA adapter 1 PCs FEATURES Front Back BUTTON P B SR101 Status LED ABCD Bypass Pause Prog Monitor out AUX LINE PHONE DC24V DATE VER 000001 SRT Firmwar...

Страница 2: ...Destination of telephone Extension terminal of PABX Subscriber s C O line AUX LINE PHONE DC24V 110 60 20 0 15 743015 SR1 01 MODEL 20 0150 MADE IN TAIWAN SR101 PLUS RJ11 Service system Plug in power AU...

Страница 3: ...owing items and correct it then test again Check connection of LINE TEL Specially the valid line has to locate in the middle of RJ 11 plug Other condition is you must change the polarity of LINE Check...

Страница 4: ...X P B 1 Enable sound Available only divert in progress Disable sound Any time 3 5 mm Earphone Build in amplifier so you can direct connect a speaker Earphone Speaker Enable sounds will always active u...

Страница 5: ...3015 SR101 MODEL 20 0150 MADE IN TAIWAN 1 Press and hold on two bottom Become copier 2 Plug in power 3 Connect a speaker Led quick blinking Copier 4 Place new dialer on it Copier No need off power 5 C...

Страница 6: ...n 2 lines and each line has it s individual PIN code When you remote program and make call to your client that you will not clear to know which line you reached especially Hunting Group lines With thi...

Страница 7: ...stem connected WAITING FOR CONNECTION If no excepant country PSTN Send preset Dest prefix item 5 Send received destination Tel No but without int l prefix Send preset ending code item 8 Compare excepa...

Страница 8: ...lear if access ISR 8 9 Security Password for entry programming mode Dialer will auto backup current password when set it Next time you may use new or old password if you want keep only one please set...

Страница 9: ...accept any code Input 0P means for tolling call 4 33 Third system s Access No 16 34 Third system s PIN code and or password 16 35 Third system s Destination Prefix 16 36 Third system s Backup access N...

Страница 10: ...em 0 or X0 will be as reject or allow code 0 Reject 1 allow 4 4 How may times of silence ring tone be count will as unreachable 1 1 times 2 2 times This is unreachable defines and active If do the det...

Страница 11: ...ivert it 1 allow Any call dialed same as item 0 programmed code will divert it otherwise bypass it digit 1 define first system digit 2 define second system Item 31 Digit 1 4 Change to divert to anothe...

Страница 12: ...ling only Dialer use this time as system connected if ever detected a signal then go silence that means connected Please know must great than inter pause time of ring back tone if have Default is 3 se...

Страница 13: ...0X but 00X86 Divert to second system Item DATA Item DATA Item DATA Item DATA 1 21 31 2 41 2 00 22 32 42 3 4378371 23 98723451 33 43 4 987654210 Account 24 23456735234 34 44 5 002 25 002 35 45 6 26 36...

Страница 14: ...ept 020 080 and however send 1807 if dial 18XX Item DATA Item DATA Item DATA Item DATA 1 21 31 41 1011 2 00 22 09 32 0P 42 18 3 23 98723451 33 43 4 24 23456735234 34 44 5 007 25 09 35 18070 45 1807 6...

Страница 15: ...test disable sound or pull out speaker Meaning of LED status Working Mode Standby Hang up and non ringing Scan slowly Press B key before lift handset Next call will bypass Scan quickly Just lift hand...

Страница 16: ...home any time when you want to monitor Available only if PTT support DTMF type of Caller ID signals FSK type N A Auto call out to inform you when add alarm switch and triggered Optional but ver 1 0X...

Страница 17: ...n time 70mS min Inter Digit Pause 70mS min Pulse Sender Speed 9 9 PPS M B 33 66 Inter digit pause 800mS DC resistance On hook 12 Mega ohms Off hook 93 ohms 20mA 200 ohms 96mA AC resistance On hook 100...

Страница 18: ...item of tone pulse dialing C O can not receive the dialing signal of dialer Set wrong number in item 3 Correct item 3 Can not make a call after dial all numbers like hear busy tone or unobtainable vo...

Страница 19: ...uble Remote control effect the call Disable remote control Subscriber s line in bad contact Inspect wires Talks with noise or echo Bad system s carrier No solution Right 1st LED is keep lighting C O o...

Страница 20: ...e like drop open case plug in high power or improper installation 3 Damage caused or occurring during shipment of dialer What is damage or malfunction Test at both parities agreed place and measuremen...

Отзывы: