31
Q700M Rev.A
Removal of brake lever from 2-pole standard motors
Preparation
Note!
Switch off the wheelchair via remote control
Instructions
Note!
Suitable work area required!
•
Follow the illustrated instruction for removing the brake
lever from the motor.
•
Rebuild the wheelchair in reverse order once completed.
•
In order to complete this, you must first tilt the chair back,
remove battery cover and remove shrouds.
Tools used
2.5
NOTE: This applies to the 2-pole standard motors.
Fig. 6.2.37
1.
Unscrew and remove (A) from the brake lever
Fig. 6.2.38
2.
Remove brake lever cover (B), O-ring and plastic clip (C)
Fig. 6.2.39
3.
Unscrew and remove 4 (D) from the main brake cover
4.
Remove main brake cover (E) from the motor assembly
1
A
2
B
C
3
4
D
E
D
Fig. 6.2.37
Fig. 6.2.38
Fig. 6.2.39