5900A Powerchair Owner’s Manual DCR1236
magicmobility.com.au
38
8.1 LED joystick module
8
Joystick controls
LED JOYSTICK TROUBLESHOOTING
If the problem persists after you have made the checks below, contact your authorised agent.
*If motor swap has been enabled, then the left and right references will need transposing.
1
Battery needs charging or there is a bad connection to the battery. Check
the battery connection. If connections are good, try charging the battery
2
Left hand motor* has a bad connection. Check the connections to
the left hand motor
3
Left hand motor* has a short circuit to a battery connection. Contact
your service agent
4
Right hand motor* has a bad connection. Check the connections to
the right hand motor
5
Right hand motor* has a short circuit to a battery connection.
Contact your service agent
6
Powerchair is being prevented from driving by an external signal.
The exact cause will depend on your powerchair model
7
Joystick fault is indicated. Make sure that the joystick is in the centre
position before switching control system on
8
Possible control system fault is indicated. Make sure that all
connections are secure
9
Parking brakes have a bad connection. Check the parking brake and motor
connections. Make sure the control system connections are secure
10
Excessive voltage has been applied to the control system. This is usually
caused by poor battery connection. Check battery connections
7+ S
Communication fault is indicated. Make sure the joystick cable is securely
connected and not damaged
ACTUATOR
FLASH
Actuator trip is indicated. If more than one actuator is fitted, check
which actuator is not working correctly. Check the actuator wiring
8.2 LCD joystick module
DIAGNOSTIC SCREEN
Diagnostic screen displays when the control safety circuits have
operated to prevent the powerchair from moving. If the error is in
a non-active module with a drive profile selected, then driving is
still possible and diagnostic screen will appear intermittently.
A = trip code B = identified module C = trip text