9
A. Construction and characteristics
•
Transportable terrace/garden heater with tank housing.
•
Casing in steel with powder
-
coating or in stainless steel.
•
Gas hose connections with metal clamp (screw caps for Germany). Heat emission from reflector.
B. Specifications
•
Use propane, butane or their mixtures gas only.
•
Max. wattage: 14000 watts
•
Min. wattage: 5000 watts
•
Consumption:
C. Table of injector
•
The hose and regulator assembly must conform to local standard codes.
•
Regulator outlet pressure should meet the corresponding appliance category in B. Specification.
•
The appliance requires approved hose in 1.4m length.
A regulator (compliees with EN16129:2013 and the national regulation) of the correct pressure corresponding to the appliance category.
Use 30mbar regulator for butane/propane under the category I3B/P(30). Use 30mbar regulator for butane under the category I3+(28
-
30/37).
Use 37mbar regulator for propane under the category I3+(28
-
30/37).
Use 50mbar regulator for butane/propane under the category I3B/P(50).
It
’
s recommended to use flexible hose that approved by EN16436: 2014.
PARTS AND SPECIFICATIONS
APPLIANCE CATEGORY:
I3+(28
-
30/37)
I3B/P(30)
I3B/P(50)
TYPES OF GAS:
Butane
Propane
Butane, propane or
their mixtures
Butane, propane or
their mixtures
GAS PRESSURE
28
-
30 mbar
37 mbar
30 mbar
50 mbar
OUTLET PRESSURE
OF REGULATOR:
30 mbar
30 mbar
30 mbar
50 mbar
Using the proper regulator according to outlet pressure of regulator as showed in the table above.
APPLIANCE CATEGORY:
I3+(28
-
30/37)
I3B/P(30)
I3B/P(50)
TYPES OF GAS:
Butane
Propane
Butane, propane or
their mixtures
Butane, propane or
their mixtures
GAS PRESSURE
28
-
30 mbar
37 mbar
30 mbar
50 mbar
TOTAL HEAT
INPUT
(Hs): (Qn)
14 kW (1000 g/h)
INJECTOR SIZE
1.90 mm for main burner
0.18 mm for pilot burner
1.70 mm for main burner
0.18 mm for pilot burner
The marking, for example, 1.90 on the injector, indicates that the size of injector is 1.90 mm
EN