background image

 

SUNPOWER CORPORATION 

Safety and Installation Instructions - Document 514744 Rev B 

 

 

©2015 SunPower Corporation. All rights reserved. Specifications included in this manual are subject to change without notice.

 

Modules  that  feature  antireflective  glass  are  susceptible  to  visible  fingerprint 
marks if touched on the front surface. SunPower recommends handling modules 
having antireflective glass with gloves or limiting touching of the front surface. Any 
fingerprints resulting from installation will naturally disappear over time or can be 
reduced by following the washing guidelines in Section 6.0.  Product datasheets 
specify the glass type used by a particular module.        

6.0

 

Maintenance

 

Visually  inspect  all  modules  annually  for  safe  electrical  connections,  sound 
mechanical connection, and freedom from corrosion. This visual inspection should 
be performed from the ground, unless performed by trained SunPower dealers or 
trained SunPower support personnel.  
 
Periodic  cleaning  of  modules  is  recommended,  but  is  not  required.    Periodic 
cleaning has resulted in improved performance levels, especially in  regions with 
low levels of annual precipitation (less than 18.25 inches [46.3 cm]). Consult your 
dealer or supplier about recommended cleaning schedules for your area.  To clean 

a module, wash with potable, non-heated water. Normal water pressure is more 
than adequate, but pressurized water (up to1500 psi) may be used.  Fingerprints, 
stains, or accumulations of dirt on the front surface may be removed as follows: 
first rinse off area and let soak for 5 minutes. Re-wet the area and then use a soft 
sponge or seamless cloth to wipe glass surface in a circular motion. Fingerprints 
typically can be removed with a soft cloth or sponge and water after wetting. Do 
not  use  harsh  cleaning  materials  such  as  scouring  powder,  steel  wool,  scrapers, 
blades, or other sharp instruments to clean module glass. Use of such materials or 
cleaning without consultation will invalidate the product warranty

.       

          

 

 
 
 
 
 
 

Table 2: Electrical Characteristics 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  

 

Maximum output fault current (ac) 

I rms 

Total 

duration 

Synchronization in 

rush current 

Trip Time Accuracy 

69.5 Apk 

38 A 

5.53 mS 

0.2A 

20mS 

 
 
 

Содержание Equinox SPR-E19-320-C-AC

Страница 1: ... for AC Modules United States and Canada Contents of this manual are subject to change without notice For the latest guide please refer to www sunpower com PVInstallGuideACModule SunPower Corporation www sunpower com Document 514744 Rev B ...

Страница 2: ...ceration hazards An authorized person should remove the module from the array and contact the supplier for disposal instructions Do not install or handle modules when they are wet or during periods of high wind Contact your module supplier if maintenance is necessary Save these instructions 3 0 Electrical Characteristics AC Output Characteristics All AC module electrical output characteristics are...

Страница 3: ... resulting load rating achieved for each module configuration Fig 2 Mounting locations for SunPower modules Table 1 Mounting Configurations and Load Resistance Module Configuration Mounting configuration valid mounting location in mm Load rating Wind up down Snow down Module size Frame type frame color End mount A1 Pressure clamp or clip B1 Frame holes C1 96 cell G5 black 300 400 3000Pa 6000Pa 50 ...

Страница 4: ...of modules is recommended but is not required Periodic cleaning has resulted in improved performance levels especially in regions with low levels of annual precipitation less than 18 25 inches 46 3 cm Consult your dealer or supplier about recommended cleaning schedules for your area To clean a module wash with potable non heated water Normal water pressure is more than adequate but pressurized wat...

Страница 5: ...PORATION Safety and Installation Instructions Document 514744 Rev B 2015 SunPower Corporation All rights reserved Specifications included in this manual are subject to change without notice Fig 3 96 Cell AC Modules ...

Отзывы: