CAUTION & SAFETY 

WARNING - TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING

 

1.

 

Installation  work  and  electrical  wiring  must  be  done  by  qualified  person(s)  in 

accordance with all applicable codes and standards. 

2.

 

Do not damage existing wiring and other hidden utilities/devices when cutting or 

drilling into a wall or ceiling. 

3.

 

Use  this  unit  only  in  the  manner  intended  by  the  manufacturer.  If  you  have 

questions, contact the manufacturer. 

4.

 

Mounting  of  the  suspension  system  and  replacement  of  parts  of  the  safety 

suspension system shall be performed by the manufacturer, its service agent, or 

suitably qualified persons. 

5.

 

Do not operate any fan with a damaged cord or plug. Please contact manufacturer 

and qualified technician for examination and/or repair. 

6.

 

Before servicing or cleaning unit, turn off all the power switches to prevent power 

from being switched on accidentally. When the circuit breaker cannot be locked, 

securely fasten a prominent warning device, such as a tag, to the service panel. 

7.

 

SUNON  provides  installation  guide  for  mounting  fans;  however,  it  is  the  sole 

responsibility  of  the  building  owner  and  installer  to  ensure  the  safety  of  the 

mounting  system,  that  the  building  structure  is  sound  and  that  the  installation 

complies with all federal, state, and local codes. 

8.

 

While turning on power to the fan, please use it with caution. DO NOT connect the 

fan to a damaged/dangerous power source. DO NOT attempt to resolve electrical 

problems by yourself. Please SEND the fan back to authorized service center for 

examination  and/or  repair.  If  there  is  any  question  with  installation,  please 

contact customer service. 

9.

 

When  service  or  replacement  of  a  fan  component  requires  the  removal  or 

disconnection  of  a  safety  device,  the  safety  device  is  to  be  reinstalled  or 

remounted as previously installed. 

10.

 

Do  not  bend  the  airfoils  when  installing,  servicing,  or  cleaning  the  fan.  Do  not 

insert foreign objects between rotating airfoils. 

Содержание UFO3 BCEE1BA100A-01S

Страница 1: ...TD UFO 3 INSTALLATION 2019 12 23 V1 UFO3 HVLS FAN 4 2 m 3 6 m 3 0 m 2 5 m 14 ft 12 ft 10 ft 8 ft Original Instructions BCEE1BA100A 01S BCEE1BA120A 01S BCEE1BA144A 01S BCEE1BA168A 01S BCNE1BA120A 01S BCNE1BA144A 01S BCNE1BA100A 01S BCNE1BA168A 01S ...

Страница 2: ... switches to prevent power from being switched on accidentally When the circuit breaker cannot be locked securely fasten a prominent warning device such as a tag to the service panel 7 SUNON provides installation guide for mounting fans however it is the sole responsibility of the building owner and installer to ensure the safety of the mounting system that the building structure is sound and that...

Страница 3: ... with the appliance 12 SUNON Fans product warranty will not cover equipment damage or failure that is caused by improper installation or use 13 If unusual oscillating movement is observed immediately stop using the ceiling fan and contact the manufacturer its service agent or suitably qualified persons 14 UFO ceiling fan controller is equipped with a memory function After disconnecting power it st...

Страница 4: ...hts and interests please make sure that the deals records the purchase date dealer s name etc on the guarantee Table of Contents 1 Introduction 2 Product Specifications 3 Installation Precautions 4 The Placement Clearance between fan and obstructions 5 Inside the Box 6 Tools Required for Installation 7 Pre Installation Checklist 8 Installation Method 9 Wiring Diagram 10 Remote Control Operation In...

Страница 5: ...gn brings excellent airflow to space We assure you this appliance will make your space cozier and occupant comfort in the near future Fan Outline D H1 H2 H3 H4 Model D A B H1 H2 H3 H4 BCEE1BA100A 01S BCNE1BA100A 01S 2 5m 8ft 350mm 1 1ft 200mm 0 65ft 643mm 2 1ft 840mm 2 8ft 1000mm 3 3ft 133mm 0 4ft BCEE1BA120A 01S BCNE1BA120A 01S 3 0m 10ft BCEE1BA144A 01S BCNE1BA144A 01S 3 6m 12ft BCEE1BA168A 01S B...

Страница 6: ... 114 166 245 335 UFO3 HVLS Fan 3 m 10 ft Model BCEE1BA120A 01S BCNE1BA120A 01S Input Voltage VAC Input Frequency Hz Rated Power W Rated Current A Maximum RPM RPM Noise dB A 200 240 50 60 232 1 44 100 40 Button 1 2 3 4 5 6 Speed RPM 50 60 70 80 90 100 Power Consumption W 34 53 83 115 164 232 UFO3 HVLS Fan 3 6 m 12 ft Model BCEE1BA144A 01S BCNE1BA144A 01S Input Voltage VAC Input Frequency Hz Rated P...

Страница 7: ...tage VAC Input Frequency Hz Rated Power W Rated Current A Maximum RPM RPM Noise dB A 200 240 50 60 171 1 1 56 40 Button 1 2 3 4 5 6 Speed RPM 30 35 40 45 50 56 Power Consumption W 27 43 64 90 120 171 Forward The ceiling fan should rotate counterclockwise Looking up from the ground Reverse The ceiling fan should rotate clockwise Looking up from the ground ...

Страница 8: ...The HVLS fan model covered by the installation instructions must comply with this installation manual and all national local electrical codes to avoid personal injury or property damage 10 Please ensure that this application is equipped with AC single phase 200 240 V before installation 11 All fan parts must be 0 6 m 2 ft from all obstructions The fan installation area must be free of obstructions...

Страница 9: ...r 17 Pleases see the manufacturer s requirements for the minimum clearance to combustibles 18 The fan inlet or other return air point that produces negative pressure should be bigger than 1 times the diameter of the ceiling fan This system will reduce the airflow of the HVLS fan 19 Proper systems orientation will provide an enhancement to the Indoor Air Quality and occupant comfort Please refer to...

Страница 10: ...ment Clearance between fan and obstructions space from the lights at least 0 6 m away spacing between fans at least 2 5x diameter of the fans apart The tip of the airfoil need at least 0 84 m away from beam ceiling and no obstacles space from wall at least 0 6 m away 3 05 m 0 84 m 0 6 m 0 6 m ...

Страница 11: ...er The distance between the center of the ceiling fan and HVAC equipment need to at least 2x diameter The HVLS fan position need to below the HVAC outlet The distance between the center of the ceiling fan and HVAC equipment need to at least 1 5x diameter The HVLS fan position need to above the HVAC outlet HVAC Diffuser HVAC Diffuser ...

Страница 12: ...ke only can be used within the width of 100 300 mm B and thickness of 20 mm I beam Within the thickness of 14 mm t the yoke only need to use 1 yoke washer The thickness of 14 20 mm t the yoke need 2 washers We do NOT suggest to install the HVLS Fan on the fabricated I beam please consult with structural engineer to make sure your building is approved for fan installation I beam shim ...

Страница 13: ...r 1 Remote Control 1 Extension Tube 1 Extension Tube Shield 2 Safety Cable 1 Wire Rope Clamp 20 Hardware and Bolt Kits Fixed angle mount bracket shim 2 I beam shim 4 I beam clamp 2 Winglet 7 Extension Tube clamp 2 Guy wire bracket 2 Turn buckle 4 Beam Clamp Set 4 Ferrite Bead Clamp 1 Earth Wire 1 Airfoil Box Anodized Aluminum Airfoils Airfoils 7 ...

Страница 14: ...ical Installation Electrical Installation Standard wrench socket set Phillips screwdriver Standard Allen wrench set Flat head screwdriver Hydraulic cutter Multimeter Galvanized wire Ø4 mm Trim the wire length according to the situation Pair if 10 to 14 AWG strippers Torque wrench 50 300 kgf cm For inspection purpose Electronic level ...

Страница 15: ...tance between the blades and other objects building structure should be at least 2 feet 0 6 meters Please refer to The Placement Clearance between fan and obstructions Page 9 The distance between the fan and other objects means the distance between the blade tips and the objects The center to center distance between two fans should be at least 2 5 times the diameter of the fans Please refer to The...

Страница 16: ... 240 Kgf cm 2 Attach the fixed angle mount bracket to the yoke horizontally and tighten with 4 sets of Fixed angle mount bracket M10x35L 4 bolt kit Recommended Tightening Torque 24 N m 240 Kgf cm 3 Attach the Fixed angle mount bracket shims to the Fixed angle mount bracket and fixed them by Extension tube M10x70L 3 bolt kit on the top position as picture shows Recommended Tightening Torque 24 N m ...

Страница 17: ... the extension tube clamp into the extension tube make sure the chamfer as picture shows is downward and tighten with 6 sets of extension tube clamp M8x 15L 6 bolt kit Recommended Tightening Torque 12 N m 120 kgf cm 6 Insert the motor tube in the extension tube clamp then take out the earth wire and guy wire bracket as picture shows to tighten with motor tube with 3 sets of M8x 55L 3 bolt kit Reco...

Страница 18: ...s make sure the U shaped inside the wire rope clamp is tighten to the short side a Wire Rope Clamp 4 b Safety Cable 1 8 1 Through Earth Live and neutral wires into ferrite bead clamp and wrap a circle 8 2 Connecting the Earth Live and neutral wires with motor and mains power Please refer to Wiring Diagram Page 15 L Live wire N Neutral wire E Earth wire U Shaped Short side Long side Mains Power Saf...

Страница 19: ...ide first with 4 sets of extension tube shied blot kit while installing on extension tube Recommended Tightening Torque 5 N m 50 Kgf cm 10 1 Prepare 4 guy wires with Ø4mm when installation The technician needs to prepare guy wire and tailor it according to the situation 10 2 Looking up from the bottom of ceiling fan the angle between each cable and I beam is recommended to be 45 degrees 10 3 The a...

Страница 20: ...mp tightly 11 2 Tailor the guy wire according to the situation Guy Wire Bracket Recommended Tightening Torque 5 N m 50 Kgf cm Beam Clamp Set Guy Wire Bracket 4 8 12 1 Attach the beam clamps to the I beam and securely fasten to the proper position based on step 11 12 2 Pass the safety cable through the ring and secure with guy wire bracket Beam Clamp Set Recommended Tightening Torque 12 N m 120 Kgf...

Страница 21: ...lance Repeat this step to complete 4 sets of wire rope bolt kit to secure the turnbuckle a Guy Wire Bracket 8 b Turnbuckle 4 Recommended Tightening Torque 5 N m 50 Kgf cm 14 Insert the winglet into the airfoil and tighten with 7 sets of winglets M6x35L 7 bolt kit as picture shows Recommended Tightening Torque 5 N m 50 Kgf cm 15 Insert the airfoil into the airfoil holder and tighten with 21 sets of...

Страница 22: ...er installation UFO3 HVLS Fan installation should follow national electrical code and standard Requirements for Electrical Power This Appliance connecting to 200 240 voltage AC Please see the voltage sticker on this HVLS fan avoid any voltage changes in case of danger damage during installation Model Airfoil Dimension Input Power Source Rated Current BCEE1BA100A 01S BCNE1BA100A 01S 2 5 m 8 ft 200 ...

Страница 23: ...North America GREEN BLACK WHITE Europe GREEN YELLOW BROWN BLUE Taiwan GREEN YELLOW BROWN BLUE Other GREEN YELLOW BROWN BLUE END USER FAN Live Wire Neutrul Wire Earth Wire WiringDiagram QF Circuit Breaker Recommend 20 A H Extension tube Notes A set of terminals can be connected to the flexible cord for fixed wiring For example crimped connector or other similar devices UFO 3 ...

Страница 24: ...ssfully Press the button to switch the fan direction it will give 2 beeps after the fan receive successfully when the fan Reverse 2 long beep and the airflow move upwards Looking up from the ground the rotation is clockwise Forward 2 short beep and the airflow move downwards Looking up from the ground the rotation is counterclockwise Press these two buttons at same time to enter pairing process Af...

Страница 25: ...stallation Remove the battery cover and install two AAA batteries Remove the batteries when not used a long time Please recycle the used batteries Operating Instructions 1 Make sure the fan blades are standstill before you turn on the fan every time 2 Press 0 to turn off the fan DO NOT touch the fan and blade until its standstill 3 Once you press any buttons the fan will receive the final order an...

Страница 26: ...olved before reaching out the service Refer to the tips below before contacting Customer Service Symptom Possible Solutions Abnormal sound from the fan Airfoil noise occurs when airfoils are not tightened to the specified torque Turn off the fan power and then tighten the airfoil fasteners to 50 kgf cm If the abnormal sound still occurs please confirm if the airfoils are not contacting each other ...

Страница 27: ...se a gentle cleaner or degreasing agent when dusting the motor DO NOT use chlorine based cleaning products in case the toxic fatal fumes exposure 6 Check all the connections such as safety cables mounting parts is tighten Also make sure the mounting system is securely tighten Any wobbling problems should not happen when you switch on the fan If any wobbling problem is noticed make sure the mountin...

Страница 28: ...e excluded from our warranty service Repairing request will be accepted but the customer will be charge for cost and service fee 1 Damage of improper installation 2 Damage of retrofit 3 Damage of force majeure Nature actions of third parties 4 Damage of misuse abuse accident 5 Damage of improper transportation 6 The warranty document purchase date or purchase confirmation like invoice from authori...

Страница 29: ...IC MACHINE INDUSTRY CO LTD UFO 3 INSTALLATION 2019 12 23 V1 Sunonwealth Electric Machine Industry Co Ltd 80673 No 30 Ln 296 Xinya Rd Qianzhen Dist Kaohsiung City 806 Taiwan R O C w w w s u n o n c o m E mail sunon sunon com ...