background image

15 

 

EXERCISE COMPUTER 

   

FUNCTION BUTTONS: 

   

MODE: 

1. Press the button to select hour, minute, year, month and date for setting. 

2. Press the button to select TIME, DISTANCE, CALORIES and PULSE to 

preset. 

3. Press the button to select function displaying on main LCD or enter after 

setting. 

4.  Press  the  button  to  confirm  setting  value  of  Gender,  Age,  Height  and 

Weight. 

5. Press the button and hold for 2 seconds to reset all value to zero.  

    (Replacing batteries will reset all values to ZERO automatically.) 

NOTE:  If  the  time,  date,  and  year  are  not  set  up  in  the  beginning,  you  must  remove  the 

batteries and reinsert them to set up these functions. Previous data will not be saved.   

SET: 

1. Set up the time, year, month and date. 

2. Set up the target value of TIME, DISTANCE, CALORIES and PULSE. You can hold the button to 

increase the value fast. 

3. Set up the personal data of Gender, Age, Height and Weight for Body Fat test. 

RESET: 

1. Press the button to reset function value when setting. 

2. Press  the  button  and  hold  for  2  seconds  to  reset  all  values  to  ZERO  (Replacing  batteries  will 

reset all values to ZERO automatically.). 

BODY FAT: 

Press  this  button  to  enter  Body  Fat  measuring  function.  Next,  press  MODE  button  to  enter  your 

personal data of Gender, Age, Height and Weight. After finished setting, press again to measure 

your Body Fat percentage (FAT%) and BMI. 

RECOVERY:

   

To activate the heart rate recovery function after pulse signal. Press any button to return to the main 

display.

 

   

FUNCTIONS : 

SCAN: 

Automatically  scans  through  each  mode  in  sequence  every  6  seconds.  The  cycle  of  functions 

showing on display is RPM-SPEED

TIME

DISTANCE

CALORIES-PULSE on the main screen. 

TIME: 

Accumulates the total time from 00:00 up to 99:59. The user may preset target time by pressing the 

SET & MODE buttons. Each increase is 1 minute   

   

Содержание SF-RB420046

Страница 1: ...420046 USER MANUAL IMPORTANT Please retain owner s manual for maintenance and adjustment instructions Your satisfaction is very important to us PLEASE DO NOT RETURN UNTIL YOU HAVE CONTACTED US support...

Страница 2: ...he equipment The equipment is designed for adult use only 4 Use the equipment on a solid flat level surface with a protective cover for your floor or carpet To ensure safety the equipment should have...

Страница 3: ...2 EXPLODED DIAGRAM 1...

Страница 4: ...3 EXPLODED DIAGRAM 2...

Страница 5: ...Bolt M6 40 4 45 Bolt M8 55 4 15 Washer 6 12 1 0 11 46 Nut M8 1 16 Square End Cap 50 25 2 47 Adjusting Foot Pad M8 30 1 17 Screw M10 20 4 48 Left Pedal JD 22A 1 18 Spring Washer 10 4 49 Right Pedal JD...

Страница 6: ...2 71 Wave Washer 17 21 0 3 2 98 Screw M6 12 2 72 Belt PJ390 1 99 Bearing 6001 2 73 Nut M6 4 100 Flywheel 240 1 74 Spring Washer 6 4 101 Flywheel Axle 1 75 Bolt M6 15 4 102 Bearing 6003 2 76 Belt Pulle...

Страница 7: ...in order for us to accurately identify the part s needed The model number found on cover of manual The product name found on cover of manual The part number found on the EXPLODED DIAGRAM and PARTS LIS...

Страница 8: ...No 111 Remove 4 Plastic Washers No 109 and 2 Shipping Tubes No 67 from Main Frame No 1 You may save these parts Screws No 11 Plastic Washers No 109 Shipping Tubes No 67 in case you would like to repac...

Страница 9: ...ting Tube No 8 with 4 Washers No 19 4 Spring Washers No 18 and 4 Screws No 17 that were removed Tighten and secure with Allen Wrench No 111 Attach the 2 Sliding Rail Covers No 42 to the Main Frame No...

Страница 10: ...ension Wire No 53 as shown in drawing A Then pull Tension Control Wire No 63a upward and insert it into the slot of metal bracket of Tension Wire No 53 as shown in drawing B Make sure the metal fittin...

Страница 11: ...rench No 111 Attach the Front Handlebar No 5 to the Front Post No 4 with 2 Bolts No 60 and 2 Spring Washers No 39 that were removed Tighten and secure with Allen Wrench No 111 Attach Clamp Cover No 61...

Страница 12: ...8669 STEP 9 Attach the Backrest Cushion No 13 to the Seat Support Bracket No 9 with 4 Bolts No 14 and 4 Washers No 15 Tighten and secure with Spanner No 112 STEP 8 Attach the Rear Handlebar No 6 to t...

Страница 13: ...ghten and secure with Spanner No 112 STEP 11 Remove 4 Screws No 58 from the back of the Computer No 59 with the Spanner No 112 Connect the Extension Sensor Wire I No 56 with Computer Wire A No 59a And...

Страница 14: ...on is complete BATTERY REPLACEMENT 1 Press the buckle of battery cover on the back of the Computer No 59 then remove battery cover 2 Remove the 2 old AA batteries in the battery case and install 2 new...

Страница 15: ...n Control Knob No 63 counter clockwise to decrease the level of resistance Tension levels are set at Level 1 being the lowest and Level 12 being the highest ADJUSTING THE SEAT To adjust the seat forwa...

Страница 16: ...o increase the value fast 3 Set up the personal data of Gender Age Height and Weight for Body Fat test RESET 1 Press the button to reset function value when setting 2 Press the button and hold for 2 s...

Страница 17: ...a long beeping sound When the batteries are removed all the function values will be reset to ZERO or default value 2 Set current data Press the SET and MODE buttons to set up current time year month a...

Страница 18: ...FAT button and hold on handle pulses to start the body fat testing 9 4 It takes a few seconds to test the body fat If you did not hold onto the handle pulses during the test procedure the LCD will sh...

Страница 19: ...nd battery springs are in proper contact with batteries 3 The batteries in the computer may be unresponsive Change to new batteries The recumbent bike wobbles when in use Turn the adjustable end caps...

Страница 20: ......

Отзывы: