background image

10

UP2, v5, SL4240

USER MANUAL

 © 2020, Sunna Design, Inc.

Motion sensor (optional)

Adding a motion sensor (optional) allows a more powerful lighting during 30s 

when motion is detected. This solution aims to combine a strong lighting power 

with a long autonomy. 

 

 

Settings are set at the factory. The number of detections depends on chosen 

lighting profile (contact us for further informations) and the detection will stop  

if the level of energy left in the battery goes below 20%.

Technical characteristics:

Detectable difference in temperature between the target  

and background is more than 4°C (7,2°F)  

Movement speed: 2,6 to 3.2 fps

Detection object = human body  

(minimal size is 27,5 in. x 9,8 in.)

3h

1h

MOTION DETECTION

20%

0%

100%

LED

DAY

NIGHT

DAY

Diagram 2:  

Example of lighting profile

Содержание Sol UP2

Страница 1: ...UP2 v5 SL4240 Z10076 00_A USER MANUAL UP2 USER MANUAL solarlighting com Sunna Design Inc 2020 Sunna Design reserves the right to modify the information in this document...

Страница 2: ...e it will give you satisfaction This manual will familiarize you with the features and operation standards of SOL s UP2 Solar Street Light UP2 v5 SL4240 USER MANUAL 2020 Sunna Design Inc Non contractu...

Страница 3: ...for the installation of the products 2 USAGE PRECAUTIONS Do not open the product without formal written authorization from Sunna Design Inc as this will invalidate the warranty Changes or modification...

Страница 4: ...0 USER MANUAL For safety reasons please ensure that every element is correctly attached and tightened on the product 0 1 in Allen key 0 15 in Allen key 0 5 in socket wrench Required tools non fournis...

Страница 5: ...specifications wind exposition soil characteristics etc in order to have a safe installation SOL liability won t be engaged in case of pole related incident Light Pollution Shading Angle 60mm 1 2 N S...

Страница 6: ...5 Etapes d installation Installation steps x4 7 x2 x2 x4 6 9 8 Bracket installation Spigot installation and tilt adjustment cf p 4 1 2 UP2 v5 SL4240 USER MANUAL 2020 Sunna Design Inc...

Страница 7: ...the pole Bracket and lantern installation 3 4 Max 500mm x2 11 Crosse non fournie Bracket not included UP2 v5 SL4240 USER MANUAL 2020 Sunna Design Inc Non contractual visuals lanterns may differ depen...

Страница 8: ...7 Start up steps Start up Initialization 5 6 UP2 v5 SL4240 USER MANUAL LED status 2020 Sunna Design Inc...

Страница 9: ...ay the system will not recharge the battery At nightfall the LED module will switch on at full power whatever the battery s charge level cf diagram 1 BLACKOUT RISKS DURING THIS STAGE The next day the...

Страница 10: ...ness of the solar charging including dirt and dust snow leaves debris shade that may have developed after installation due to adjacent plant growth Green LED Orange LED Red LED Description ON ON ON In...

Страница 11: ...The number of detections depends on chosen lighting profile contact us for further informations and the detection will stop if the level of energy left in the battery goes below 20 Technical character...

Страница 12: ...to return to the operating range FLASH FLASH OFF Defective night detection Light pollution on the panel Move the product if presence of indirect lighting on the panel OFF OFF OFF Electronic defect Ha...

Страница 13: ...12 UP2 v5 SL4240 USER MANUAL 2020 Sunna Design Inc...

Страница 14: ...com ADDRESS Sunna Design Inc 990 Biscayne Boulevard Office 701 Miami FL 33132 USA sales solarlighting com toll free 800 959 1329 Sunna Design Inc 2020 Sunna Design reserves the right to modify the inf...

Отзывы: