WARNING / AVERTISSEMENT

RISK OF ELECTRIC SHOCK

•  Turn power off before installation, inspection, cleaning 

or removal. And follow appropriate lock out/tag out 

safety procedure.

•  Properly ground electrical enclosure.

•  Follow all National Electric Codes (NEC) and local codes.

•  This product must be installed in accordance with the 

applicable installation code by a person familiar with 

the construction and operation of the product and the 

hazards involved.

•  The installation and associated structures are subject to 

approval by the authority having jurisdiction.

•  Use only with components identified in this document.

•  Suitable for dry, damp locations.

•  Do not expose lamp to water. The lamp may shatter 

and cause injury.

•  Wear suitable Personal Protective Equipment (PPE) 

during installation/maintenance. Highly recommend 

safety glasses, helmet and leather gloves for luminaire 

mounting.

•  Luminaire design for Greenhouse only.

•  Suitable for operation in an ambient temperature 

between 0°C and 40°C.

•  Do not keep combustible materials below lamp. While 

lamp breaking is extremely unlikely hot lamp parts may 

fall and cause property damage.

•  Do not turn on lamp until fully installed.

RISQUE DE CHOC ELECTRIQUE

•  Coupez l’alimentation avant l’inspection, l’installation ou la 

désinstallation.

•  Reliez correctement le boîtier électrique à la mise à la terre.

•  Suivre tous les codes électriques locaux applicables. 

•  Ce produit doit être installé selon le code d’installation 

pertinent, par une personne qui connaît bien le produit et 

son fonctionnement ainsi que les risques inhérents.

•  L’installation et les structures associées sont soumises à 

l’approbation des autorités compétentes.

•  Utilisez uniquement avec les composants identifiés dans ce 

document.

•  Convient aux endroits secs, et mouillés.

•  N’exposez pas la lampe à l’eau. La lampe peut se briser et 

causer des blessures.

•  Portez les équipements de protection individuelle appropriés 

pendant l’installation et la maintenance. L’utilisation de 

lunettes de sécurité, d’un casque et des gants de cuir pour le 

montage du luminaire est fortement recommandée.

•  Luminaire conçu pour serres seulement.

•  Opération compatible avec un environnement à 

température ambiante controlée entre  0°C et 40°C.

•  Ne pas garder de matière combustible sous la lampe. Bien 

que le bris de la lampe est extrêmement improbable, les 

pièces chaudes de la lampe peuvent tomber et causer des 

dommages à la propriété.

•  Ne pas allumer la lampe avant d’avoir terminé l’installation.

Cylindrical reflector

Open reflector

Horticulture Lighting System

Installation Guide

Arize

TM

 H1000 Luminaire

GEHPS-DE1000 Series

Caution: Special purpose lamps.

Not suitable for household illumination.

Attention: Lampes à usage spécifique

Ne conviennent pas à l’éclairage domestique.

Содержание Arize H1000

Страница 1: ...lamp until fully installed RISQUE DE CHOC ELECTRIQUE Coupez l alimentation avant l inspection l installation ou la désinstallation Reliez correctement le boîtier électrique à la mise à la terre Suivre tous les codes électriques locaux applicables Ce produit doit être installé selon le code d installation pertinent par une personne qui connaît bien le produit et son fonctionnement ainsi que les ris...

Страница 2: ... NMB 005 du Canada Modifying or opening the system will void the warranty Before resetting the ballast please allow 15 minutes for the lamp to cool down When your system cannot be ignited please check the LED indicator first to diagnose the problem and find a solution Check if all the connections are correct If the lamp is still off please contact the manufacturer or distributor Please Note Attent...

Страница 3: ...escription Product Quantity Product Weight lbs kg Dimensions in L x W x H Voltage Current Power Factor 93121131 GEHPS DE1000 4CS4N1 1000W Cylindrical Reflector 41mm Hangers 1 7 43 3 37 12 3 x 9 x 21 277 347 VAC 50 60Hz 4 8 3 8A 0 95 93121132 GEHPS DE1000 4OS4N1 1000W Open Reflector 41mm Hangers 1 7 32 3 32 12 7 x 9 3 x 21 277 347 VAC 50 60Hz 4 8 3 8A 0 95 93121133 GEHPS DE1000 4CS5N1 1000W Cylindr...

Страница 4: ...ss to properly secure the eyebolt 2 For the other eyebolt first slide a nylon washer and a spring washer onto one of the studs above the ballast Then thread and tighten down a hexagonal standoff onto the stud After that follow the steps above to properly secure the eyebolt into the hexagonal stud 3 Ready to mount Reflector Installation Instructions 1 Align the two holes on the reflector to the two...

Страница 5: ...d LAMP MAY SHATTER AND CAUSE INJURY IF BROKEN Wear safety glasses and gloves when handling lamp Do not use lamp if outer glass is scratched or broken Do not use excessive force when installing lamp RISQUE DE BRÛLURE Laisser l ampoule et le réflecteur refroidir avant de les manipuler Ne pas allumer la lampe avant d avoir terminé l installation L AMPOULE PEUT ÉCLATER ET CAUSER DES BLESSURES SI ELLE ...

Страница 6: ...plied that such performance will be obtained under end use conditions 2019 GE Current a Daintree company www LED com HORT131 Rev 11 27 19 A 1021353 List of Components Ballast Lamp Holder Reflector Options Mounting Options Bracket GEHPS RFT OPN DE10 GEHPS RFT CYL DE10 Reflector Options 41mm hook 2 Conforms to the following standards 51mm hook 2 Eyebolts 2 Mounting Options 216319 1 2 3 4 5 1 2 3 4 5...

Отзывы: