background image

3

LED Indicator Function

Flash Frequency

Status

Description and Solution

Flashing Once

Ballast Locked

The ballast tried to light the lamp five times. Disconnect and reconnect power 

source.

Flashing Twice

Output Error

The lamp stopped for unknown reason. Check whether the lamp is correctly 

mounted.

Flashing Three Times

Low Input Voltage

The input voltage is too low. Ensure the input voltage matches the power cord and 

ballast specifications.

Flashing Four Times

High Temperature

The ballast has overheated. Reduce the ambient temperature.

Flashing Five Times

Lamp Error

Lamp voltage is too high or too low. Ensure lamp matches specifications.

Flashing Six Times

High Input Voltage

The input voltage is too high. Ensure the input voltage matches the power cord and 

ballast specifications.

Product Specifications

The LED indicator is designed to help troubleshoot minor issues with the ballast. 
The LED indicator statuses are as follows:
•  LED off: no power supply/with power supply.
•  LED flashing: see below table for flash pattern and resolutions:

SKU

Description

Description

Product 

Quantity

Product 

Weight

lbs (kg)

Dimensions

in. (L x W 

x H)

Voltage

Current Power 

Factor

93121131 GEHPS-DE1000-4CS4N1 1000W, Cylindrical Reflector,

41mm Hangers

1

7.43(3.37)

12.3 x 9 x 21 277/347 VAC,50/60Hz 4.8/3.8A > 0.95

93121132 GEHPS-DE1000-4OS4N1 1000W, Open Reflector,

41mm Hangers

1

7.32(3.32)

12.7 x 9.3 x 21 277/347 VAC,50/60Hz 4.8/3.8A >0.95

93121133 GEHPS-DE1000-4CS5N1 1000W, Cylindrical Reflector,

51mm Hangers

1

7.43 (3.37)

12.3 x 9 x 21 277/347 VAC,50/60Hz 4.8/3.8A >0.95

93121134 GEHPS-DE1000-4OS5N1 1000W, Open Reflector,

51mm Hangers

1

7.32 (3.32)

12.7 x 9.3 x 21 277/347 VAC,50/60Hz 4.8/3.8A >0.95

93121135 GEHPS-DE1000-5CS4N1 1000W, Cylindrical Reflector,

41mm Hangers

1

7.12 (3.23)

12.7 x 9.3 x 21

480 VAC,50/60Hz

2.6A >0.95

93121226 GEHPS-DE1000-5OS4N1 1000W, Open Reflector,

41mm Hangers

1

7.01 (3.18)

12.3 x 9 x 21

480 VAC,50/60Hz

2.6A >0.95

93121227 GEHPS-DE1000-5CS5N1 1000W, Cylindrical Reflector,

51mm Hangers

1

7.12 (3.23)

12.7 x 9.3 x 21

480 VAC,50/60Hz

2.6A >0.95

93121228 GEHPS-DE1000-5OS5N1 1000W, Open Reflector,

51mm Hangers

1

7.01 (3.18)

12.7 x 9.3 x 21

480 VAC,50/60Hz

2.6A >0.95

93121229 GEHPS-BLB-1000W-DE

Double-Ended 

100W HPS Bulb

12

-

-

-

-

-

93121230 GEHPS-RFT-CYL-DE10

Cylindrical Reflector

10

-

-

-

-

-

93121231 GEHPS-RFT-OPN-DE10

Open Reflector

5

-

-

-

-

-

Содержание Arize H1000

Страница 1: ...lamp until fully installed RISQUE DE CHOC ELECTRIQUE Coupez l alimentation avant l inspection l installation ou la désinstallation Reliez correctement le boîtier électrique à la mise à la terre Suivre tous les codes électriques locaux applicables Ce produit doit être installé selon le code d installation pertinent par une personne qui connaît bien le produit et son fonctionnement ainsi que les ris...

Страница 2: ... NMB 005 du Canada Modifying or opening the system will void the warranty Before resetting the ballast please allow 15 minutes for the lamp to cool down When your system cannot be ignited please check the LED indicator first to diagnose the problem and find a solution Check if all the connections are correct If the lamp is still off please contact the manufacturer or distributor Please Note Attent...

Страница 3: ...escription Product Quantity Product Weight lbs kg Dimensions in L x W x H Voltage Current Power Factor 93121131 GEHPS DE1000 4CS4N1 1000W Cylindrical Reflector 41mm Hangers 1 7 43 3 37 12 3 x 9 x 21 277 347 VAC 50 60Hz 4 8 3 8A 0 95 93121132 GEHPS DE1000 4OS4N1 1000W Open Reflector 41mm Hangers 1 7 32 3 32 12 7 x 9 3 x 21 277 347 VAC 50 60Hz 4 8 3 8A 0 95 93121133 GEHPS DE1000 4CS5N1 1000W Cylindr...

Страница 4: ...ss to properly secure the eyebolt 2 For the other eyebolt first slide a nylon washer and a spring washer onto one of the studs above the ballast Then thread and tighten down a hexagonal standoff onto the stud After that follow the steps above to properly secure the eyebolt into the hexagonal stud 3 Ready to mount Reflector Installation Instructions 1 Align the two holes on the reflector to the two...

Страница 5: ...d LAMP MAY SHATTER AND CAUSE INJURY IF BROKEN Wear safety glasses and gloves when handling lamp Do not use lamp if outer glass is scratched or broken Do not use excessive force when installing lamp RISQUE DE BRÛLURE Laisser l ampoule et le réflecteur refroidir avant de les manipuler Ne pas allumer la lampe avant d avoir terminé l installation L AMPOULE PEUT ÉCLATER ET CAUSER DES BLESSURES SI ELLE ...

Страница 6: ...plied that such performance will be obtained under end use conditions 2019 GE Current a Daintree company www LED com HORT131 Rev 11 27 19 A 1021353 List of Components Ballast Lamp Holder Reflector Options Mounting Options Bracket GEHPS RFT OPN DE10 GEHPS RFT CYL DE10 Reflector Options 41mm hook 2 Conforms to the following standards 51mm hook 2 Eyebolts 2 Mounting Options 216319 1 2 3 4 5 1 2 3 4 5...

Отзывы: