1.19. Priority Tank:
This option will only display if you are configuring a system with two tanks (as discussed in
sections
1.4.2 / System 2
and
1.4.3 / System 3
)
Designate one of the system tanks as
priority
(
tank1
or
tank2
). The
priority
tank will always be
activated first unless one of the following situations occur.
NOTE:
Default setting is No Prio
The second tank will become operational when:
x
The
priority
tank reaches the
Maxtemp
value entered on the
Setting
menu (
Section 2
)
for that particular tank (if
tank1
is designated
priority
, the applicable setting will be the
Maxtemp tank1
; if
tank2
is
priority
,
Maxtemp tank2
).
Note: When the temperature in the
priority
tank falls below the temperature set for
MinTemp
Prio
(
Setting
menu),
priority
will switch back from the second tank to the original
priority
tank.