2.
Width of silicone glue strips should exceed 10 mm and height of the strips
should exceed 4 mm. Glue 3 strips along the module’s length side and 1
strip along the edge of the windward side
;
3.
Please maintain a 50mm gap between the silicone glue strips along the
windward side and the strips along the length side to create ventilation loops
;
4.
Applying the silicone glue should be a continuous and even movement.
Please use a roller to spread out the glue strips evenly. Do not shave the glue
strips to spread them out
;
5.
Make sure to complete the gluing and mounting over a duration that does not
exceed 5 minutes
;
6.
Silicone sealant will cure to a depth of 2-3mm in 48 hours. Do NOT apply
any force on the module before curing is complete
;
7.
If the mounting surface is corrugated or wave-shaped, please glue along the
middle line of the wave crest.
6.4 Construction plan
Installation steps
6.4.1
Cleaning the roof surface
Remove debris from the roof base and use a designated or approved cleaning
agent (Annex C) to clean the roof. If the roof is very dirty, use a low-pressure water
spray or power washer before using the cleaner. Use (1/4 cup of trisodium phosphate,
1/2 cup of liquid cleaner (optional)) and 5 gallons of water) for cleaning.
6.4.2 Positioning and releasing the line
◼
Locate the line and determine the installation position of the module
;