Troubleshooting Tips

If the Hercules 2 is not performing as expected, try the following:

 

A.  Confirm that your power input is active from your breaker panel and providing 120 or 

240 Volts/ 50 Amps/60 Hz to the controller.

 

B.  Check the voltage input from the ‘Power Input’ wires using a voltage test meter to 

verify power is flowing to the controller.

 

C.  Then confirm that power is active and proper at the ‘Power Output’ wires.

 

D.  Make sure all of your connections are tight.  Loose connections can cause “arcing”.

 

E.  Verify that your equipment is functioning properly and that there are no shorts or 

arcing occurring.

 

F.  Should you find your circuit breaker keeps tripping, check your breakers to verify that 

they are the right amperage for your application.  Replace circuit breaker if necessary.

Still having problems with your Hercules 2?  Please contact our Technical Service Representative 
to assist you further.

Controller Specifications:

• Size = 8.5”H x 9”W x 4”D

• Weight = 5 lbs.

• Voltage Input = 120 OR 240 VAC 

• Voltage Output = 120 OR 240VAC 

*Relay Coil Voltage = 120 Volts

• Maximum Amperage = 50 Amps

• Hertz = 60Hz

*Electrical Relay Operations = 100,000 Cycles

• RoHS compliant = Yes

• Storage Temperature = 32°F (0°C) to 135°F (57°C) 

• Operating Temperature = 40°F (5°C) to 125°F (52°C)

Installation Example

Sun System 

R

Sun System 

R

Sun System 

R

Hercules 2

Relay Trigger 

Cord Set

Kronus Series 

Controller

Light Bank

OR

OR

OR

Power In

Titan Apollo 

24 HR 

Timer

Heater

Air Conditioner

Controlling an Air Conditioner, Heater or Light Bank