background image

 11. Operation example settings

Example: ZONE A control 1000W ballast, output power is 

780W, sunrise time 08:35,(60% power), sunset time 9:00 

(turn off), Sunrise and sunset duration time is 29min, if  

ambient temperature is 30°C 

 temperature 

 40, dimming 

down automatically to decrease power and temperature. If  

temperature >40°C, turn off and enter into protection status. 

 12. Sun System

®

 1 Etelligent

 Controller technical parameters

Power

DC5V/2A

Match ballasts

600W and 1000W

Control command time interval

2S

Power Dimming Scope

600W: 40%-110% (240W-660W)

1000W: 60%-115% (600W-1150W)

Power regulation accuracy

1%

Temperature-controlled  

adjustable inspection scope

32° - 104°F (0° - 40°C)

Temperature-controlled  

protection inspection scope

50° - 122°F (10° - 50°C)

Sunrise and sunset duration

0-30 min

Turn on delay protection time

0min, 5min, 10min, 15min, 20min, 25min and 30min

 13. Sun System

®

 1 Etelligent

 Controller TROUBLESHOOTING

Problem

Inspection method

Troubleshooting

Controller doesn’t have any  

display after plugging in power

Check the power supply

Reset power supply

Check the adapter

Change to another adapter

Check the controller

Change to another controller

Fail to control ballasts

Check the connection of  

controller and ballasts, make sure 

each connection is good

Reconnect the wires

Controller doesn’t have any  

temperature display after  

temperature probe connected

Check if the temperature  

probe is damaged

Change to another  

temperature probe

Fail to turn on the lamp

Check the LED on the ballast to  

ensure the LED indicator above  

the out plug is flashing normally

Reconnect the wire

Ballast does not appear to  

be functioning on desired  

setting sent via controller

Check the sunrise and sunset  

time setting

Reset sunrise or sunset time

Check the temperature probe  

and temperature-controlled value  

you selected

Change the temperature-  

control value you set

When some ballasts are  

not functioning properly  

on a channel

Check if the connection  

wire between ballasts is  

functioning properly

Replace connection wire  

or unplug and then plug  

in again

Check the connection  

of the power cable

Plug in and out to try again

Check if the ballast is  

functioning properly

Check the LED on ballast

Содержание Sun System 1

Страница 1: ...TION MANUAL Vancouver WA Eureka CA Livermore CA Ontario CA Denver CO Detroit MI York PA Nashville TN Pompano Beach FL Vancouver B C Canada sunlightsupply com Control Sun System 1 Etelligent Ballasts with the same controller operating on 2 separate channels ...

Страница 2: ...re connecting to controller please make sure the knob is rotated to RC position first 1 AC Adapter 120 240V 1 Patch Cord 2 Control Cables For connecting ballast to ballast No magnetic ring on cable Forconnectingballast tocontroller Magnetic rings on cable 2 Temperature Probes 2 Sun System One Controller accessories 3 Connection between ballast and controller ETELLIGENT CONTROLLER ZONE A up to 200 ...

Страница 3: ...ease temperature LED FAST FLASH High temperature exceeded preset value Ballast turned off 2 LED LIGHT ON Lamp on LED LIGHT OFF Lamp off 3 Same as 1 4 Same as 2 1 2 3 4 7 Setting the time NOTE Set controller time to your time zone 1 Press t or u enter into SYSTEM SETTING 2 Press t or u to the parameter you want to set Time for example Hour Minutes 3 Press p Hour value will increase Press q Hour val...

Страница 4: ...enter into the Time Setting 9 Setting the timer dimming 1 Press NEXT then OK to enter into ZONE A NOTE Follow this same setup for ZONE B 2 Press t or u choose o choose time and power percentage press p or q to þ 3 Then press t or u to choose the time and power percentage and press p or q to increase or decrease the time and power percentage value 4 After all value settings are set press OK to save...

Страница 5: ...ing in power Check the power supply Reset power supply Check the adapter Change to another adapter Check the controller Change to another controller Fail to control ballasts Check the connection of controller and ballasts make sure each connection is good Reconnect the wires Controller doesn t have any temperature display after temperature probe connected Check if the temperature probe is damaged ...

Страница 6: ...s trying to ignite the lamp Ignition busy Flash 6 7 Lamp voltage is too high or too low Lamp fault Flash 7 14 LED failure indicator on electronic ballast Note 1 Without controller connected Dimming LED indicator will remain on If failure occurs the Turbo LED indicator will flash one of seven possible issues listed above 2 With controller connected The controller LED will remain on and flash Contro...