11 of 13
OPERATION:
LEAK TEST
!!!WARNING!!!
A leak check must be performed whenever the gas cylinder is replaced.
1. Make sure the control knob is in the “OFF” position.
2. Make sure the gas cylinder is correctly and securely connected to the pressure regulator, without over
tightening.
3. Turn on the gas cylinder valve. Apply 50% soap and 50% water solution to the gas hose and
connections between the control knob and gas cylinder.
4. If something is leaking, you will see bubbles form. In case of leaks, turn off the gas supply, undo the
leaking connection, re-connect it and try again. If the leak persists, consult Customer Service Center for
assistance (
1(866) 578-6569
).
5. If the connection does not leak, continue to the next step.
LIGHTING THE BURNERS
1. Make sure control valve is OFF.
2. Turn on gas tank valve.
3. Press in and turn control valve knob counterclockwise to LOW to light.
See the figure to the right.
4. If burner is lit, continue pressing in the control valve knob for a minute to
heat the thermocouple.
5. When control valve knob is released, the burner should be lit. If not, turn
control valve knob clockwise to OFF. Wait for 5 minutes then start with
step 3 above.
6. Press in and turn control valve knob to desired heat output, LOW ~
HIGH.
`
Fig.7
Fig 8
OFF
HIGH
MAX
BAS
ARRET
LOW
Содержание Stoneridge L-DN1773SST-D-T
Страница 5: ...5 of 13 EXPANDED VIEW...