8 of 11
OPERATION
LEAK TEST
1- Make sure the control knob is on the “OFF” position.
2- Make sure the gas cylinder is correctly and securely connected to the pressure regulator, without
over tightening it.
3- Turn on the gas cylinder valve. Apply 50% soap and 50% water solution to the gas hose and
connections between the control knob and gas cylinder.
4- If something is leaking, you will see bubbles form. In case of leaks, turn off the gas supply, undo the
leaking connection, re-connect and try again. If the leak persists, consult Sunjoy Industries Customer
Service Center for assistance.
5- If the connection is sound, continue next step.
IGNITE LIGHTING
1- Make sure control valve is OFF.
2- Turn on gas tank valve.
3- Press in and turn control valve knob counterclockwise
to High to light. (See the right figure)
4- If burner is lit, release pressing in control valve knob for
a minute to heat thermocouple.
6- When control valve knob is released, burner should be lit. If not, turn control valve knob clockwise
to OFF. Retry to light after waiting 5 minutes from step 3.
7- Press in and turn control valve knob to desired heat input, HIGH ~ LOW.
!!!WARNING!!!
Do not use an open flame to check for leaks.
Do not smoke during testing.
Do not test indoors.
A leak check must be performed whenever the gas cylinder is replaced.
L O W
H I G H
O F F
O N
Fig 6
Fig 6