Sunjoy 810367912 Скачать руководство пользователя страница 4

4 of 15 

gas leak. Have the appliance inspected annually by a qualified service person.   

  The  pressure  regulator  and  hose  assembly  provided  with  the  appliance  must  be  used. 

 

The 

replacement part must be the same as the part specified by manufacturer. 

  The  assembly of  LP-gas  and  leak checking  please  refer  to  the  “Gas connection”  on page  10  and 

“Leak Test” on page 11. 

 

Children and adults should be alerted to the hazards of high surface temperatures and should stay 

away to avoid burns or prevent clothing ignition.   

 

Young children and pets should be carefully supervised when they are in the area of the appliance. 

 

Any guard or other protective device removed for servicing the appliance must be replaced prior to 

operation.   

 

Clothing or other flammable materials should not be hung from the appliance or placed on or near the 

appliance. 

  Do not use the appliance if any part has been under water. Immediately call a qualified technician to inspect 

the appliance and to replace any part of the control system and any gas control which has been under water.   

  LP-gas supply cylinder to be used must be constructed and marked in accordance with the specifications for 

LP-gas cylinders of the U.S. Department of Transportation (DOT). 

  The cylinder supplies system must be arranged for vapor withdrawal and the cylinder must include a collar to 

protect the cylinder valve. 

  Use only 20 lb / 9 kg LP-Gas cylinders. 

  Do not burn wood or any other materials in this appliance. 

  The appliance must be isolated from the gas supply piping system by closing 

its individual manual shutoff valve during any pressure testing of the gas supply 

piping system at test pressure equal to or less than 1/2psi (3.5kPa). 

  That other cylinder may be acceptable for use with the appliance provided 

they are compatible with the appliance retention means and accompanied by illustration(s) depicting the cylinder 

mounted to the appliance utilizing the cylinder retention means and the point of contact between the cylinder and 

the retention means. 

  Properly place the hose out of pathways where people may trip over it or in areas where there may be subject 

to accidental damage. 

  The burner must be replaced prior to the appliance being put into operation if it is evident that the burner is 

damaged. The replacement burner must be the same as the part specified by manufacturer. 

  The cleaning of the appliance including the burner, please refer to “Storage and Maintenance” on page 12. 

 
 
 

Содержание 810367912

Страница 1: ...d the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in the vic...

Страница 2: ...14 Limited warranty 14 GENERAL INFORMATION IMPORTANT Please take time to read these instructions thoroughly and follow each step carefully for safe and easy operation Keep this manual to consumer for...

Страница 3: ...is gas appliance When using decorative Lava Rocks use only Lava rocks INCLUDED The appliance shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any ot...

Страница 4: ...ccordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT The cylinder supplies system must be arranged for vapor withdrawal and the cylinder must include a co...

Страница 5: ...5 of 15 EXPANDED VIEW...

Страница 6: ...D2 Table panel 2 P21109A01118 1 M Thermocouple P99001E04000 1 E Side panel P21110A01118 1 N Control Valve P99001F04000 1 F Door P20913A01118 1 O Control Knob P99001G07001 1 F1 Door handle P90007A0111...

Страница 7: ...e the parts listed please contact Customer Service Center 1 866 578 6569 Step 1 Insert the round column of the table panel 1 D1 into the hole of the side panel E then attach table panel 1 D1 to side p...

Страница 8: ...le of table panel 1 D1 Then attach gas jar frame G to table panel 1 D1 by bolt CC and washer BB as Fig 2 showed Use the same way to attach gas jar frame G to table panel 2 D2 Step 3 Put the Table Top...

Страница 9: ...ide panel E to the table top B by bolt AA and flat washer BB Note When installing the fire bowl please make sure the bowl C with control panel should face the door F Step 5 Attach the door handle F1 t...

Страница 10: ...10 of 15 Step 6 Put the Lid A on the Table Top B Step 7 The lava rock H should be put in the bottom of the Fire Bowl C and come up just as high as the fire ring...

Страница 11: ...ry into the bottom of battery box as shown in Fig 2 Then screw the battery box as shown in Fig 3 Fig 1 Fig 2 Fig 3 Note If the battery of the pulse electronic igniter runs out of power please replace...

Страница 12: ...ks turn off the gas supply undo the leaking connection re connect it and try again If the leak persists consult Customer Service Center for assistance 1 866 578 6569 5 If the connection does not leak...

Страница 13: ...building garage or any other closed area The fireplace may be stored indoors only if the cylinder is disconnected and removed Keep the fireplace area clear and free from combustible materials gasoline...

Страница 14: ...aired or replaced at the discretion of the manufacturer at no cost to the original purchaser This warranty will be void if the product has not been assembled installed or operated according to the ins...

Страница 15: ...run the burner on high for 30 minutes 4 Once lit do not go within 10 feet of the fire pit for the first 30 minutes on the first use 5 After the first 30 minutes resume normal operation Do not stand ov...