background image

3 of 15 

SPECIFICATION 

 

IMPROTANT SAFETY INFORMATION AND PRECAUTION 

  When the appliance is for connection to a fixed piping system, the installation must conform with 

local codes, or in the absences of local codes with the 

National Fuel Gas Code, ANSI Z223.1

/NFPA54; 

International Fuel Gas Code, Natural Gas and Propane Installation Code, CSA B149.1; or Propane 
Storage and Handling Code, B149.2, as applicable.   

  The LP gas supply cylinder to be used must be: 

1-  Constructed and marked in accordance with the U.S. Department of Transportation (D.O.T.)   

Specifications for LP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for 
transportation of Dangerous Goods and Commission, CAN/CSA-B339 as applicable; 

2-  Provided with a listed overfilling prevention device; 
3-  Provided with a cylinder connection device compatible with the connection for the appliance. 

  Always place the appliance on a firm and level surface.   

  Solid fuels shall not be burned in this gas appliance. When using decorative Lava Rocks, use only 

Lava rocks (INCLUDED). 

  The appliance shall be used only outdoors in a well-ventilated space and shall not be used in a 

building, garage or any other enclosed area. 

  When  in  use,  keep  the  appliance  area  clear  and  at  least  40  in  /  101.6  cm  side 

DQGWRS

clearance 

from combustible  materials,  gasoline  and  other  flammable  liquid  and vapors.  Do not  use the appliance 
under overhead combustible surfaces. Certain items or materials, when stored under the appliance or 
nearby, will be subjected to radiant heat and could be damaged.

 

 

  Open the door and inspect the hose assembly and burner prior to each use. If there is evidence of 

excessive abrasion or wear or if the hose or burner is damaged, it must be replaced by appropriate 
part from the manufacturer. 

  Inspect the gas connections of the appliance prior to each use. Do not operate the unit if there is a 

Product name 

Stoneridge Fire Pit High Dining Table 

Model NO. 

L-DN1773SST-D-T2 

Rated Heat Output 

38,000BTU/HR 

Fuel 

Propane-LP 

Gas Supply 

20 lb. LP-Gas cylinder 

Manifold Pressure 

11 Inches W.C. 

Orifice Size (diameter) 

1.9mm   

 

 

Gas Supply Pressure 

Max.250 PSI 

Содержание 810367912

Страница 1: ...d the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in the vic...

Страница 2: ...14 Limited warranty 14 GENERAL INFORMATION IMPORTANT Please take time to read these instructions thoroughly and follow each step carefully for safe and easy operation Keep this manual to consumer for...

Страница 3: ...is gas appliance When using decorative Lava Rocks use only Lava rocks INCLUDED The appliance shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any ot...

Страница 4: ...ccordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT The cylinder supplies system must be arranged for vapor withdrawal and the cylinder must include a co...

Страница 5: ...5 of 15 EXPANDED VIEW...

Страница 6: ...D2 Table panel 2 P21109A01118 1 M Thermocouple P99001E04000 1 E Side panel P21110A01118 1 N Control Valve P99001F04000 1 F Door P20913A01118 1 O Control Knob P99001G07001 1 F1 Door handle P90007A0111...

Страница 7: ...e the parts listed please contact Customer Service Center 1 866 578 6569 Step 1 Insert the round column of the table panel 1 D1 into the hole of the side panel E then attach table panel 1 D1 to side p...

Страница 8: ...le of table panel 1 D1 Then attach gas jar frame G to table panel 1 D1 by bolt CC and washer BB as Fig 2 showed Use the same way to attach gas jar frame G to table panel 2 D2 Step 3 Put the Table Top...

Страница 9: ...ide panel E to the table top B by bolt AA and flat washer BB Note When installing the fire bowl please make sure the bowl C with control panel should face the door F Step 5 Attach the door handle F1 t...

Страница 10: ...10 of 15 Step 6 Put the Lid A on the Table Top B Step 7 The lava rock H should be put in the bottom of the Fire Bowl C and come up just as high as the fire ring...

Страница 11: ...ry into the bottom of battery box as shown in Fig 2 Then screw the battery box as shown in Fig 3 Fig 1 Fig 2 Fig 3 Note If the battery of the pulse electronic igniter runs out of power please replace...

Страница 12: ...ks turn off the gas supply undo the leaking connection re connect it and try again If the leak persists consult Customer Service Center for assistance 1 866 578 6569 5 If the connection does not leak...

Страница 13: ...building garage or any other closed area The fireplace may be stored indoors only if the cylinder is disconnected and removed Keep the fireplace area clear and free from combustible materials gasoline...

Страница 14: ...aired or replaced at the discretion of the manufacturer at no cost to the original purchaser This warranty will be void if the product has not been assembled installed or operated according to the ins...

Страница 15: ...run the burner on high for 30 minutes 4 Once lit do not go within 10 feet of the fire pit for the first 30 minutes on the first use 5 After the first 30 minutes resume normal operation Do not stand ov...