User Manual
9 Appendix
69
Technical
Specifications
SG2KTL-S
SG2K5TL-S
country’s grid standard)
THD
<3% (Nominal power)
DC current injection
<0.5% In
Power factor
>0.99@default value at nominal power
(adj. 0.8 over-excited~0.8 under-excited)
Protection
Anti-islanding
protection
Yes
AC short circuit
protection
Yes
Leakage current
protection
Yes
DC switch
Optional
DC fuse
No
Overvoltage
protection
Varistors
System Data
Max. efficiency
98.00%
98.00%
Max. European
efficiency
97.00% 97.40%
Isolation method
Transformerless
Ingress protection
rating
IP65
Night power
consumption
<1 W
Operating ambient
temperature range
-25
℃
…+60
℃
(
>
45
℃
derating)
Allowable relative
humidity range
0…100%
Cooling method
Natural cooling
Noise level
≤
30dB
Max. operating
Altitude
4000m(
>
2000m derating)
Communication WiFi
DC Terminals
MC4
AC Terminals
Plug and play connector
Certification
I
EC61000-6-2,IEC61000-6-3,AS/NZS3100,AS4777.2,AS477
7.3,VDE-AR-N-4105,VDE0126-1-1,CE,G83/2,C10/11,EN504
38,CGC
Mechanical Data
Dimensions(W
×
H
×
D)
300
×
370
×
125mm