6 Commissioning
6.1 Inspection before Commissioning
Check the following items before starting the inverter:
1.
The inverter DC switch and external circuit breaker are disconnected.
2.
The inverter should be accessible for operation, maintenance and
service.
3.
Nothing is left on the top of the inverter.
4.
The inverter is correctly connected to the external devices, and the
cables are routed in a safe place or protected against mechanical
damage.
5.
The selection of the AC circuit breaker is in accordance to this manual
and all applicable local standards.
6.
All unused terminals at the bottom of the inverter are properly sealed.
7.
Warning signs and labels are suitably affixed and durable.