SG1K5TL
User Manual
44
Type of fault
Troubleshooting
No-grid
1. Check whether AC circuit breaker is off.
2. Check whether AC cables are all firmly connected.
3. Check whether grid is cut off.
4. If all conditions are OK and this malfunction still occurs in the LCD
screen, please contact Sungrow.
Tem-flt
1. Check whether AC output power exceeds rated power too much.
2. Check the state of the fans.
3. Check whether there is some foreign body blocking the air inlet and
outlet. Clean air grills of air vent.
Com-flt
1. If this malfunction happens, wait for a while and observe whether fault
can be cleared by the inverter itself.
2. Otherwise perform the command “Stop”.
3. Perform the command “Start” to restart the inverter.
4. If this malfunction still exists, please contact Sungrow.
If you have any problems in operating on the inverter, please contact us:
Telephone: +86 551 532 7834/532 7845
Email:
We need the following information to provide you the best assistance:
y
Type of the inverter
y
Serial number of the inverter
y
Fault
name
y
Simple description of the fault phenomenon
Содержание SG1K5TL
Страница 1: ......
Страница 6: ...1 SAFETY AND PRODUCT INFORMATION For Installer and User...
Страница 7: ...2...
Страница 12: ...7 2 Product Introduction About This Chapter This chapter provides basic information about inverter SG1K5TL...
Страница 18: ...13 INSTALLATION AND MAINTENANCE INFORMATION Only for Installer...
Страница 19: ...14...
Страница 50: ...45 OPERATION INFORMATION For User and Installer...
Страница 51: ...46...
Страница 55: ...SG1K5TL User Manual 50 8 3 Overview of LCD Menu Fig 8 1 Menu Tree English...
Страница 65: ...SG1K5TL User Manual 60...