Sunfire XTEQ10 Скачать руководство пользователя страница 5

5

User's Manual

User's Manual

1. Crossover Frequency

This control changes the high frequency 

cutoff point. With the control set to 100 Hz, 

the subwoofer will reproduce frequencies 

up to 100 Hz. If the control is set fully 

clockwise, the crossover is bypassed 

and the subwoofer will reproduce a wide 

frequency range. With the control fully 

counter-clockwise the subwoofer reproduces 

a narrow range, up to 30 Hz.

Rotate the control until the bass sounds 

natural. If the mid-bass sounds natural but 

you want more low bass, turn this control 

down a little, then turn the Level control up 

by about the same amount. This increases 

the low-bass output while leaving the mid-

bass output the same.

2. Level

This control lets you match the output 

level of the subwoofer to the level of your 

other speakers. The subwoofer output will 

increase as this control is rotated clockwise. 

When you initially install this subwoofer in 

your system, turn this down before turning 

on your subwoofer. This will prevent any 

loud surprises.

3. Phase Control

This control changes the relative phase 

of the subwoofer with respect to the other 

speakers. Use this control to help blend the 

subwoofer with the rest of the system. This 

is accomplished by adjusting the control in 

small increments as you listen for the most 

bass at your listening position. As a final 

trim, readjust the Crossover Frequency and 

volume controls after the Phase has been set.

4. Trigger Input 

The trigger input can be used to 

automatically turn on the subwoofer from 

Standby mode. To do this, c12 

VDC to the positive (+) terminal, and 

ground to the negative (–) terminal. Many 

of the currently available high quality Home 

Theater Receivers and Preamplifiers  have 

matching12 VDC Trigger outputs. When 

they are turned on, the subwoofer will “be 

triggered” to turn on.

5. Line Level Inputs

Connect these unbalanced inputs with RCA 

type patch cords to the line level outputs of 

your receiver or preamp. If your preamplifier 

or receiver has a single sub/LFE output, 

connect it to either input jack.

Control Panel Features

2

3

4

5

1

9901375_Rev-A_Sunfire_XTEQ_User_Manual_0812_PRINT_ENG.indd   5

8/12/14   7:10 PM

Содержание XTEQ10

Страница 1: ...ELECTOR User s Manual XTEQ 8 XTEQ 10 XTEQ 12 Subwoofer VOLTAGE SELEC TOR 100 120 V T10AL 250V 220 240 V T6AL 250V 50 60 Hz 900 W 9901375_Rev A_Sunfire_XTEQ_User_Manual_0812_PRINT_ENG indd 1 8 12 14 7...

Страница 2: ...cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Prot gez le cordon d alimentation d tre pi tin ou pinc particuli rem...

Страница 3: ...and Care 4 Control Panel Features 6 Installation 8 Connections 9 Location 10 Room Equalization Procedure 12 System Configurations 14 Specifications 18 TroubleshootingGuide 20 Limited Warranty 22 Servi...

Страница 4: ...e big breakthrough features of the subwoofer are its innovate tracking down converter amplifier its long throw high back electromotive force driver and its fully automatic room equalizer Taken togethe...

Страница 5: ...This will prevent any loud surprises 3 Phase Control This control changes the relative phase of the subwoofer with respect to the other speakers Use this control to help blend the subwoofer with the r...

Страница 6: ...nnections 8 Output Switch This switch affects the frequency range of the line level outputs In the bypass position the outputs are a full range copy of the input signals In the 85 Hz position the outp...

Страница 7: ...ption has been factory configured for 100 120v Should the AC voltage need to be changed to 220 240v please complete the following steps Always unplug the power cord and all other connections before mo...

Страница 8: ...2 inches away from any walls The metal bottom plate serves as the amplifier heat sink and also as a conduit to remove internal heat to the outside AC Power Considerations Ensure that the unit is plugg...

Страница 9: ...ssibility of an audible hum in your system caused by a ground loop Whenever possible keep the power cords away from the signal cables or speaker wires to prevent any hum or interference being heard in...

Страница 10: ...ic samples with heavy bass Walk around the room listening and stand in all the positions where you might be able to place the subwoofer Location Try crouching down and try the corners Find a place for...

Страница 11: ...anced auto equalization system available As you found in the last exercise Location subwoofer performance is greatly affected by the room in which it is situated and the positioning within the room Th...

Страница 12: ...llow the steps outlined below 1 Install the subwoofer in the best location for your room see previous section 2 The calibration must be done while the listening room is quiet Please turn off any noisy...

Страница 13: ...is the procedure for the Room Equalization 1 If you are using two XTEQ subwoofers make sure that they are connected using the SLAVE output of the first sub to the SLAVE input of the second 2 Back pane...

Страница 14: ...ire Subwoofer s crossover frequency is set to 100 Hz This is by no means an ironclad rule rather it is a good starting point Refer to the crossover frequency control details within this document as we...

Страница 15: ...cks often contain differential L R bass The opening scene in Transformers for example has loads of L R bass information If this is not preserved the bass in these scenes sounds anemic Therefore system...

Страница 16: ...ASS or 85 Hz In the 85 Hz position the signals coming out of the subwoofer s outputs are a copy of the signals going into the subwoofer except that the low bass is filtered out This uses the subwoofer...

Страница 17: ...s not require any connections to its line level inputs Before the EQ procedure make sure that both XTEQ subwoofers are connected together as shown The microphone should be connected to the first subwo...

Страница 18: ...Line Level RCA Nominal Impedance 15k Input Mono Balanced XLR Nominal Impedance 14k Balanced XLR Nominal Impedance 14k Balanced XLR Nominal Impedance 14k Slave Line Level Mono RCA Nominal Impedance 8k...

Страница 19: ...19 s Manual User s Manual VOLTAGE SELEC TOR 100 120 V T10AL 250V 220 240 V T6AL 250V 50 60 Hz 900 W 9901375_Rev A_Sunfire_XTEQ_User_Manual_0812_PRINT_ENG indd 19 8 12 14 7 10 PM...

Страница 20: ...plifier or receiver s sub output is turned on Some systems only have a sub output signal when the front speakers are set to small If the preamplifier s subwoofer LFE output has an adjustable crossover...

Страница 21: ...come from outside the room such as cable TV satellite TV or roof top antennas Make sure that they are disconnected where they first enter the room so they are making no connection to your preamplifier...

Страница 22: ...nger available and cannot be repaired effectively Core Brands at its sole option may replace it with a different model of equal or greater value or refund the original purchase price paid THE FOREGOIN...

Страница 23: ...that Core Brands only sells its products via the Internet through a select group of authorized Internet dealers These are listed on our website at www sunfire com Products offered on the Internet thro...

Страница 24: ...re is a registered trademark of Corebrands LLC a Nortek company All other trademarks are the property of their respective owners We reserve the right to change specifications descriptions and prices w...

Отзывы: