background image

Scenario 5 - T-Max® Manager Series with wires
As always, this tanning booth is fully compatible with a wired T-Max® 
system. Simply connect the RJ-22 modular cable(s), described in the 
TMax® Manager manual, into the remote port(s) located on the Control 
Unit and follow the instructions that came with your remote system.

Scenario 6 - Single Booth wired to T-Max® 3A
In single sunbed installations, the T-Max® 1A and 3A can offer the 
same control as the T-Max® Manager, eliminating the need for a Man-
ager. If you’re using a 1A in this manner, it must have a chip labelled 
“master” installed on its circuit board. The remote control bypass plug 

must not be used in this configuration. The 3A may be used as a “mas

-

ter” with no modification.

After you have set the T-Max® 1A’s, or 3A’s, address to “0” (refer to 
your T-Max® user’s guide) and the booth’s address to “1”, simply con-
nect the RJ-22 modular cables, described in the T-Max® user’s guide, 
directly into either of the smaller ports located on the Control Unit and 
either port on the back of the T-Max® 1A or 3A.

Scenario 7 - Non T-Max® Remote System wired to unit
Most non-T-Max® remote systems control the sunbed by the use of a 
relay. The relay operates the sunbed by connecting and disconnecting 
a pair of wires leading from the sunbed. Refer to the user’s manual pro-
vided with your remote system to determine if it operates in this way. 
To connect your booth to this type of system a remote interface kit is 

required. Contact your place of purchase to obtain the kit. The illustration 
below details a typical connection. Follow the instructions provided with 

the kit and from the remote’s manual to make the necessary connections.

Setting the address manually

Before connecting your booth to the T-Max® Manager or T-Max® 1A or 

3A, the address of your booth must first be set. Set the address manually 

as described below.

Setting the Address

Make sure the display is showing “0”.

Press the red stop button and, without releasing it, press the green 
timer button and hold both for three seconds. The display should 
indicate an address number from “1” to “255”.

If you are using a T-Max® 1A or 3A as a “master” remote, the ad-
dress of the booth must be set to “1”. If you are using a TMax® Man-
ager each sunbed must be assigned a different address. To adjust the 
address, press the green timer button to count up until the desired 
number (from 1 to 128) is achieved. Addresses 252 to 255 are not 
normally used.

Press the red stop button to return to the normal display mode.

1-99

100-128

(blinking dot)

252-255

(blinking dot)

Using Your Booth

Before using your booth, please note the following:

• Your skin should be free of cosmetics, tanning oils, or other body 

lotions prior to tanning except for those specifically made for use 

with tanning devices. However, do not remove natural body oils by 
bathing or showering immediately before tanning.

• Keep treated hair from contacting booth surfaces. Many hair prod-

ucts can damage the booth acrylic. Wear a shower cap or towel if 
you use gels, mousses, sprays, or other hair products.

• Your booth is designed for individual use. Always wear the safety 

goggles supplied with your booth or another approved pair of gog-

gles, as defined under 21 CFR 1040.20. Regular sunglasses do not 
provide adequate protection from ultraviolet light.

Follow the guidelines for skin type and exposure times as shown in the 

table below. Untanned persons should not tan on consecutive days 

during their first week of tanning. Never tan more than once a day. Tan

-

ning normally appears after the first few sessions and maximizes after 

approximately four weeks. Tan once or twice per week thereafter to 
maintain appearance. Persons already having a base tan may begin at 
advanced levels corresponding to the extent of their base tan.
Skin Type:
I  Sensitive Skin  (Burns easily and severely and does not tan.) 
II  Light Skin 

(Burns easily and severely and tans minimally.) 

III  Normal Skin  (Burns moderately and tans average.) 
IV Dark Skin 

(Burns minimally, tans easily and above average.)

5

RECOMMENDED EXPOSURE TIMES IN MINUTES

   

Level 1/Week 1 

Level 2 

Level 3 

Level 4 

Level 5

Skin Type: 

1st-3rd Sessions

I  Sensitive 

 

 NOT RECOMMENDED FOR TANNING

II Light 

10

III Normal 

10 

10

IV Dark 

10 

10

MAXIMUM EXPOSURE TIME IS 10 MINUTES

Содержание Platinum PRO48X

Страница 1: ...Make sure nothing obstructs the airflow into the booth s endcaps or out of the fan openings A poorly ventilated room may cause the unit to become hot and cause discomfort to the user Unpacking and Inspection Your booth arrives in three cardboard cartons Pull back the plastic sheet and with a helper grasp each unit and pull it from the carton bottom leaving the plastic wrap and the carton packaging...

Страница 2: ...WHEELS Connect the Door Unit to the Control Unit As before be sure the white Nylon Washer is between the hinge brackets 3 The Side Brace keeps the Control Unit and Side Unit from opening up Position the two units as shown and insert the pins on the Side Brace into the holes in the extrud ed bosses on the endcaps Move the units until the brace fits into the holes 2 Secure the body fan bracket to th...

Страница 3: ...t prématuré de la peau et provoquer le cancer de la peau PORTEZ DES LUNETTES PROTECTRICES LE NON RESPECT DE CETTE CONSIGNE DE SÉCURITÉ PEUT ENTRAÎNER DE GRAVES BRÛLURES OU DES LÉSIONS OCULAIRES À LONG TERME Les médicaments ou les produits cosmétiques peuvent augmenter votre sensi bilité au rayonnement ultraviolet Consultez un médecin avant d utiliser la lampe solaire si vous prenez des médicaments...

Страница 4: ...vide the needed power to the wireless unit Remote System Hook up Scenarios Follow the diagrams below and on the next page to see the many differ ent scenarios for hooking up your salon If you need further assistance call T Max directly at 417 272 0761 Scenario 1 T Max Manager Series with Complete Wireless Connect one G2 with Power Injector to the Manager and one G2 to each of the tanning units Ins...

Страница 5: ...display should indicate an address number from 1 to 255 3 If you are using a T Max 1A or 3A as a master remote the ad dress of the booth must be set to 1 If you are using a TMax Man ager each sunbed must be assigned a different address To adjust the address press the green timer button to count up until the desired number from 1 to 128 is achieved Addresses 252 to 255 are not normally used 4 Press...

Страница 6: ...es of the acrylic shield are now exposed Grasp the edge of the acrylic and carefully lift it out Replace the acrylic by placing it back into place Close the hinged profile by pushing it back into place until it snaps tight CAUTION Be careful The edges of the acrylic shield may be sharp PROFILE ACRYLIC 6 Operation A Timer display Displays remaining time B Timer button Turns booth on Timer display s...

Страница 7: ...th has been used 3 If remote is being used other than T Max Manager the external timer may not be activated 4 Remote wiring is incorrect see the instructions provided with the remote interface kit Timer display continues to show a 0 after the timer button is pressed 1 T Max Manager remote system has not yet been set 2 Booth address is not set correctly see Remote Connections One or more lamps fail...

Страница 8: ... changes or improve ments in its products without incurring any obligations to similarly alter products which have been previously purchased 8 Exclusivity of Warranty This warranty is the only warranty made by SUNFIRE INDUS TRIES and may only be modified or amended by a written instrument signed by a duly authorized officer of SUNFIRE INDUSTRIES SUNFIRE INDUSTRIES s sole and exclusive liability an...

Отзывы: