Changing the gas inlet:
For some countries, the gas inlet type can be different for NG/LPG gases. In such a case, remove the
current connection components and nuts (if any) and connect the new gas supply accordingly. In all
conditions, all components used in gas connections should be approved by local and/or
international authorities. In all gas connections, refer to the “Assembly of gas supply and leakage
check” clause explained before.
Figure 12
Figure 13
Figure 11
Valve with flame failure device
Valve with flame failure device
Valve without flame failure device
Bypass screw
Bypass screw
Bypass screw
(Inside the hole)
The position the bypass screw must be loosened for conversion from LPG to NG. For conversion
from NG to LPG, the same screw must be fastened. Make sure that the appliance is unpluged from
the electric mains and the gas supply is open.
13