EN -8-
Electrical connection of your hob
•
Before proceeding with the electrical
connection, verify that the current car-
rying capacity of the system and the
socket are adequate for the maximum
power rating of the hob.
•
Electrical installation throughout the
residence and the electrical current
plug in use must be earthed and con-
form with safety regulations.
•
If there is no dedicated hob circuit and
fused switch, they must be installed
by a qualified electrician before the
hob is connected.
•
Fused switch must be easily accessi-
ble once the hob has been installed.
•
Do not use adaptors, multiple sockets
and/or extension leads.
•
A circuit breaker with a contact open-
ing of at least 3 mm, rated 2
5
A and
delayed functioning type must be in-
stalled inside the supply circuit.
•
For the touch=controlled vitroceram-
ic hob, the cable must be H05VV-F
3X
2
,5 mm² / 60227 IEC 53. You will
find the connection diagram shown on
the back of your appliance.
•
During installation, please ensure that
insulated cables are used. An incor-
rect connection might damage your
appliance. The warranty will not cover
such damages.
•
All repairs must be carried out by au-
thorised service personnel or a quali-
fied electrician.
•
Unplug your appliance before each
maintenance. For reconnection, fol-
low the connection diagrams exactly.
3x2,5 mm² 220V~
3x2,5 mm² 230V~
3x2,5 mm² 240V~
5x1.5 mm² 380V 3N~
5x1.5 mm² 400V 3N~
5x1.5 mm² 415V 3N~
/
3x2,5 mm² 220V~
3x2,5 mm² 230V~
3x2,5 mm² 240V~
5x1.5 mm² 380V 3N~
5x1.5 mm² 400V 3N~
5x1.5 mm² 415V 3N~
Supply cable connection can be differ
according to terminal box type.
Содержание 8435299606190
Страница 1: ...INSTRUCCIONES DE INSTALACIÓN Y FUNCIONAMIENTO HORNILLA VITROCERÁMICA INCORPORADA 60 cm PLV4FBT ES ...
Страница 17: ...ES 1 ES 17 PLV4FBT ...
Страница 19: ...INSTRUÇÕES DE FUNCIONAMENTO E INSTALAÇÃO PLACA VITROCERÂMICA ENCASTRADA DE 60 cm PT ...
Страница 37: ...OPERATING AND INSTALLATION INSTRUCTIONS BUILT IN VITROCERAMIC HOB EN ...