background image

Limited 2 Year Warranty:

SUNEX INTERNATIONAL INC.  WARRANTS TO ITS CUSTOMERS THAT THE COMPANY’S SUNEX HD

®

 AIR TOOLS ARE FREE FROM 

DEFECTS IN WORKMANSHIP AND MATERIALS.

Sunex International Inc. will repair or replace its Sunex HD

®

 air tools which fail to give satisfactory service due to defective  

workmanship or materials, based upon the terms and conditions of the following described warranty plan. This product carries  

a TWO-YEAR warranty. During this warranty period, Sunex Tools

®

 will repair or replace at our option any tool which proves to be 

defective in material or workmanship.

Other important warranty information….

This warranty does not cover damage to tools arising from alteration, abuse, misuse, damage and does not cover any repairs or  

replacement made by anyone other than an authorized Sunex HD

®

 service center from the list above. The foregoing obligation is 

Sunex International Inc.’s sole liability under this or any implied warranty, and under no circumstances shall we be liable for any 

incidental or consequential damages.

Note:

 Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or  

exclusion may not apply to you.

Return the tool to your nearest authorized Sunex HD

® 

warranty service center, transportation prepaid. Be certain to include your 

name, address, and proof of purchase date, along with a description of the suspected defect. If you have any questions about  

warranty service, please contact Sunex Tools

®

 at 1-800-833-7869, or on the internet at www.sunextools.com. This warranty  

gives you specific legal rights and you may also have other rights which vary from state to state.

Shipping Address:

     

 

Sunex Tools

®

 • 315 Hawkins Rd. • Travelers Rest, SC 29690

Mailing Address:

Sunex Tools

®

 • P.O. Box 1233 • Travelers Rest, SC 29690

Warranty Service Centers:

Air & Hydraulic Repair

315 Hawkins Road

Travelers Rest, SC  29690

TEL# 877-786-3939

 

Power Tool Repair

891 Moe Drive Suite H

Akron, OH  44310

TEL# 330-630-0022

 

Discount Tool Repair

3433 Losee Road #1

North Las Vegas, NV  89030

TEL# 702-657-6570

Tri-County Power Tool, Inc.

4597 Pearl Rd.

Cleveland, OH 44109

(216) 398-6120

Diversified Power Inc.

90 Buttermill Avenue,

Vaughan, Ontario

L4K 3X7 Canada

Tel: 905-760-9077

Toll Free: 800-821-7975

SX7870: 

Parts Breakdown & Operating Manual 

5  

1/24/12

SX7870_Manual_012412.indd   5

1/27/12   9:13 AM

Содержание SX7870

Страница 1: ...de operar o realizar mantenimiento a esta herramienta Siempre lleve puesto protección del oído al momento de operar esta herramienta Sauvegarder ces instructions Veuillez lire le présent manuel avant d utiliser l outil Toujours porter le dispositif de protection antibruit lorsque vous utilisez cet équipement WARNING ADVERTENCIA AVERTISSEMENT Product Safety Information Información de seguridad del ...

Страница 2: ...ious injury or death Be aware of your surroundings and any excess hose left on the walking or working surface Pneumatic tools can cause vibration in use Vibration repetitive motions or uncomfortable positions over extended periods of time may be harmful to your hands and arms Discontinue use of tool if discomfort tingling feeling or pain occurs Consult a physician before resuming use if any of the...

Страница 3: ...nder our sole responsibility that the product to which this declaration relates is in conformity with the requirements of the Council Directive of June 1998 on the approximation of the laws of the Member States relating to machinery EN792 98 37 EC Harmonized Standards Applied EN 792 6 National Standards Applied ISO 8662 7 ISO 15744 2002 Machine Name SX7870 Horizontal Sander Serial No MS012010 or h...

Страница 4: ...21 Spring Pin 3 x 6L 1 22 RS787022 Spring Pin 3 x 12L 1 23 RS30524 Ball Bearing 608ZZ 3 24 RS787024 Spindle 1 REF PART NO NO DESCRIPTION QTY 25 RS787025 Retaining Ring STW 16 1 26 RS787026 Spring Washer WW 16 1 27 RS787027 Pinion Gear 1 28 RS787028 Bevel Gear 1 29 RS787029 Spacer 1 30 RS787030 Retaining Ring RTW 40 1 31 RS787031 Key 3 x 13 1 32 RS21118 Ball Bearing 6201Z 1 33 RS787033 Spindle Cap ...

Страница 5: ...the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Return the tool to your nearest authorized Sunex HD warranty service center transportation prepaid Be certain to include your name address and proof of purchase date along with a description of the suspected defect If you have any questions about warranty service please cont...

Страница 6: ...ajo Las herramientas neumáticas pueden ocasionar vibraciones durante el uso Las vibraciones movimientos repetitivos o las posiciones incómodas mantenidas durante periodos extendidos de tiempo pueden ser dañinos para las manos y los brazos Deje de usar la herramienta si se dé alguna incomodidad sensación de hormigueo o dolor Consulte un médico antes de continuar el uso si se dé cualquiera de dichas...

Страница 7: ...ta herramienta a altas presiones reducirá la vida útil de la herramienta en forma significativa y podría ocasionar lesiones La rosca de la entrada de aire en esta herramienta es de NPT 1 4 estándar La presión de la línea debe aumentarse por cualquier manguera de una longitud anormalmente larga mayor a 25 pies El diámetro mínimo de manguera debe ser de un diámetro interior de 3 8 y todas las conexi...

Страница 8: ...cial bajo ninguna circunstancia Nota Algunos estados ni permiten la exclusión ni limitación de los daños incidentales ni consecuenciales por lo que la limitación o exclusión anterior puede no aplicar a usted Devuelva su herramienta al centro de servicio garantizado autorizado Sunex HD más cercano con el flete pre pagado Asegúrese de incluir su nombre dirección y comprobación de compra junto con un...

Страница 9: ...ns inconfortables pendant de longues périodes peuvent présenter des dangers pour vos mains et vos bras Utiliser l outil de manière discontinue en cas de gêne de sensation de picotements ou de douleurs Consulter un médecin avant de reprendre le travail si l un de ces symptômes se manifeste Ne pas étirer ou tendre le bras trop loin lors de l utilisation du matériel Si l outil ne fonctionne pas conve...

Страница 10: ...impide et sec L utilisation de cet outil à des pressions plus élevées réduira considérablement sa durée de vie et pourrait causer des blessures graves Le filetage d entrée d air de cet outil est un filetage standard de 1 4 NPT La pression de fluide doit être augmentée pour l utilisation de tout tuyau d air à longueur exceptionnelle plus de 25 pieds Le diamètre minimum du tuyau doit être de 3 8 Di ...

Страница 11: ...mmage consécutif ou indirect Remarque Certains Etats ne permettent pas l exclusion ou la restriction des dommages consécutifs ou indirects ainsi il est possible que la restriction ou l exclusion ci dessus ne s applique pas à votre cas Renvoyez l outil au centre de service de garantie Sunex HD agréé le plus proche le transport est payé d avance N oubliez pas d inclure vos noms adresse et preuve de ...

Отзывы: