background image

Thermal Parameter Configuration 

Dual Vision Light Load Thermal PTZ   

User Manual 

 

48 

 

Issue  V1.0  (2019-04-03) 

 

Figure 5-4

 

FFC mode interface 

 

 

Table 5-3 describes the FFC mode parameters.   

Содержание SN-TPT4231

Страница 1: ...Bi Spectral PTZ Network Camera User Manual Issue V1 0 Date 2019 04 03 ...

Страница 2: ......

Страница 3: ... symbols whose meanings are described accordingly Symbol Description It alerts you to fatal dangers which if not avoided may cause deaths or severe injuries It alerts you to moderate dangers which if not avoided may cause minor or moderate injuries It alerts you to risks Neglect of these risks may cause device damage data loss device performance deterioration or unpredictable results It provides a...

Страница 4: ...by to discharge high energy such as thunder strikes in order to prevent device damage Unless otherwise specified do not use the camera in a temperature lower than 10 C 14 F or higher than 50 C 122 F Too high or too low temperature may cause image display anomaly of the camera and the camera will be damaged if it is working under such a condition for a long time If the camera is installed outdoors ...

Страница 5: ...personnel The manufacturer shall not be held responsible for any artificial damage of the fragile sticker Special Announcement All complete products sold by the manufacturer are delivered along with nameplates operation instructions and accessories after strict inspection The manufacturer shall not be held responsible for counterfeit products This manual may contain misprints technology informatio...

Страница 6: ...ion Method 15 3 2 Device Installation 15 3 2 1 Installation of Basic Requirements 15 3 2 2 Basic Installation Tool 15 3 2 3 Installation Space and Installation Strength 16 3 2 4 Definition of Installation Wiring Harness 16 4 Quick Configuration 18 4 1 Thermal Web 18 4 1 1 Login and Logout 18 4 1 2 Main Page Layout 19 4 1 3 Change the Password 20 4 1 4 Browse Video 21 4 1 5 Install Plugins 23 4 1 6...

Страница 7: ...reen 51 6 Visible light Parameter Configuration 53 6 1 Access the Sensor Interface 53 6 2 Sensor Setting Parameter description 53 6 2 1 Time Segment 53 6 2 2 Image Adjust 54 6 2 3 Scene Mode 55 6 2 4 Exposure 57 6 2 5 WB Setting 58 6 2 6 Daynight 60 6 2 7 Noise Reduction 62 6 2 8 Enhance Image 63 6 2 9 Zoom Focus 65 7 PTZ Function Application 67 7 1 PTZ Control function 67 7 2 PTZ configuration 68...

Страница 8: ...Overview Bi Spectral PTZ Network Camera User Manual 6 Issue V1 0 2019 04 03 8 Technical Specifications 76 A Troubleshooting 80 B Common Emission Rate 83 ...

Страница 9: ... Monitor the temperature field with object energy distributed The IR thermal imaging camera can show the temperature field of an object converting the invisible surface temperature distribution situation to a visible thermal image that reflects the surface temperature distribution situation of the object By this monitoring users can discover temperature anomaly in a timely manner and take precauti...

Страница 10: ...ower 1 2 2 Product Features The shell of the machine adopts the material of high strength aluminum alloy die casting machine with anti corrosion materials anti corrosion treatment key parts filling nitrogen seal all weather protective design IP66 protection grade can adapt to the maritime and coastal defense environment such as salt fog video monitoring application Double spiral worm gear transmis...

Страница 11: ...iption of PTZ cable 1 3 1 Multi cable Aviation power supply and network cable of twenty six cores is shown as Figure 1 1 Figure 1 2 and the description is shown in Table 1 1 Figure 1 1 Aviation power supply and network cable of twenty six cores Figure 1 2 Definition of twenty six cores ...

Страница 12: ... 7 DC36V Red Thick 8 Audio_IN G Audio masking 9 Audio_IN Audio Core 10 Alarm_OUT1 Black Thin 11 Alarm_OUT3 Blue 12 Alarm_OUT3 Pink 13 Alarm_OUT4 White 14 Audio_OUT G Audio masking 15 Audio_OUT Audio Core 16 Video Video Core 17 Video G Video masking 18 Alarm_OUT2 White and Orange 19 Alarm_OUT4 Green 20 RS485A Orange Thick 21 RS485B Yellow Thick 22 ETHTX White and Orange 23 ETHTX Orange 24 Alarm_OUT...

Страница 13: ... 0 2019 04 03 11 1 3 2 Aviation Alarm Cable Aviation alarm cable of twenty six cores is shown as Figure 1 3 Figure 1 4 and the description is shown in Table 1 2 Figure 1 3 Aviation power supply cable of twenty six cores Figure 1 4 Definition of twenty six cores ...

Страница 14: ...Reserved core Blank 8 Reserved core Ground 9 Reserved core Ground 10 Reserved core Blank 11 Alarm_IN1 White 12 Alarm_IN2 White and Orange 13 Alarm_IN3 Blue 14 Audio IN G Audio masking 15 Audio_IN Audio Core 16 Video Video Core 17 Video G Video masking 18 Audio_OUT Audio Core 19 Audio_OUT G Audio masking 20 Alarm_IN4 Pink 21 Alarm_IN5 Red Thin 22 Alarm_IN6 White and Yellow 23 Alarm_IN7 Blank 24 Ala...

Страница 15: ...Bi Spectral PTZ Network Camera User Manual Overview Issue V1 0 2019 04 03 13 ...

Страница 16: ... Dimensions Dual Vision Light Load Thermal PTZ User Manual 14 Issue V1 0 2019 04 03 2 Device Dimensions Figure 2 1 shows the dimensions of the Dual Vision Light Load Thermal PTZ Figure 2 1 Dimensions unit mm ...

Страница 17: ...nstallation 3 2 1 Installation of Basic Requirements Installation site and environment to meet the technical parameters mentioned in the requirements the installation staff should have been fully read and read the contents of this manual with the appropriate system installation qualification and maintenance work qualification certificate 3 2 2 Basic Installation Tool Commonly used engineering wiri...

Страница 18: ...cludes power line network cable RS422 geodetic line video line and according to the demand there are various types of outgoing line The details need to be controlled according to the line signature of each device Table 3 2 shows Definition of installation wiring harness Table 3 2 Definition of installation wiring harness COLOR Function define Remark BNC Video Optional Red DC36V N A Black DC36V RJ4...

Страница 19: ...sue V1 0 2019 04 03 17 COLOR Function define Remark Red RS422 RX Blue RS422 RX Yellow Green GND In order to prevent lightning strikes the grounding wire yellow green wire in the cable outlet base must be grounded reliably and the grounding resistance should be 4Ω End ...

Страница 20: ...tep 1 Open the Internet Explorer enter the IP address of IP camera default value 192 168 0 121 in the address box and press Enter The login page is displayed as shown in Figure 4 1 Figure 4 1 Login page Step 2 Input the User name and password The default user name is admin The default password is admin Change the password when you login the system for first time to ensure system security You can c...

Страница 21: ...parameter Video control PTZ control PTZ Configure and log out of the system Figure 4 2 is shown the main page layout Table 4 1 lists the elements on the main page layout Figure 4 2 Main page layout 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Table 4 1 Elements on the main page No Element Description 1 Real time video area Real time videos are played in this area You can also set sensor parameters 2 Playback ...

Страница 22: ...ose audio 10 Interphone Open or close interphone 11 Sensor setting Click the icon it will access to sensor setting 12 Snapshot Click the icon it will snapshot 13 Local record Click the icon it will record video and save 14 Intelligent analysis Open or close intelligent analysis 1 When the device generates an alarm the alarm icon is displayed You can click to view the alarm information When the dev...

Страница 23: ...e own password success is displayed the password is successfully changed If the password fails to be changed the cause is displayed For example the new password length couldn t be less than eight Step 4 Click OK The login page is displayed End 4 1 4 Browse Video User can browse the real time video in the web management system Preparation To ensure the real time video can be play properly you must ...

Страница 24: ...lorer choose Tool Internet Options Security Customer level and set Download unsigned ActiveX control and initialize and script ActiveX controls not marked as safe for scripting under ActiveX controls and plug ins to Enable as shown in Figure 4 5 Figure 4 5 Configuring ActiveX control and plug ins Step 3 Download and install the player control as prompted ...

Страница 25: ...t time Figure 4 6 Download the plugin page Procedure Step 1 Click the message download and install the plugin follow the prompts Step 2 Reopen the browser after installation End 4 1 6 Set Local Network Parameters Description Local network parameters include IP protocol IP address Subnet mask Default gateway Dynamic Host Configuration Protocol DHCP Preferred Domain Name System DNS server Alternate ...

Страница 26: ... of 32 bits Setting method Select a value from the drop down list box Default value IPv4 DHCP The device automatically obtains the IP address from the DHCP server Setting method Click the option button NOTE To query the current IP address of the device you must query it on the platform based on the device name DHCP IP IP address that the DHCP server assigned to the device N A IP Address Device IP ...

Страница 27: ...od Enter a value manually Default value 192 168 0 2 MTU Set the maximum value of network transmission data packets Setting method Enter a value manually NOTE The MTU value is range from 800 to 1500 the default value is 1500 Please do not change it arbitrarily Step 3 Click OK If the message Apply success is displayed click OK The system saves the settings The message Set network pram s success Plea...

Страница 28: ...figuration Thermal Temperature Parameters The Temperature Parameters page is displayed as shown in Figure 4 8 Figure 4 8 Temperature Parameters interface Step 2 Set the parameters according to Table 4 3 Table 4 3 Temperature parameters Parameter Description Setting Temperature Unit Celsius and Fahrenheit temperature units are available Setting method Select a value from the drop down list box Defa...

Страница 29: ...be 7 Setting method Enter a value manually Default value 0 00 Area Temperature Display Mode The display position of temperature information on the live video image Setting method Select a value from the drop down list box Default value Low left Custom Colors Enable to custom the color there are nine colors chosen Setting method Enable or disable Default value disable Area Temperature Type There ar...

Страница 30: ...erval N A Setting method Enter a value manually ranges from 1 to 1800 Default value 10 Step 3 Click Apply The message Apply success is displayed the system saves the settings End 4 1 7 2 Temperature Area Operation Procedure Step 1 Choose Configuration Thermal Temperature Area The Temperature Area page is displayed as shown in Figure 4 9 ...

Страница 31: ... to Table 4 4 Table 4 4 Temperature area and alarm configuration Parameter Description Setting Channel N A Setting method Select a value from the drop down list box Default value 1 Measure Mode Set at temperature parameter interface N A Enable Tick to enable alarm areas N A ID It ranges from 0 to19 N A Name Area name of temperature area Setting method Enter a value manually ...

Страница 32: ...ault value 48 00 Alarm Value Camera will alarm when the surveillance object temperature reaches the alarm value Setting method Enter a value manually Default value 50 00 Emission Rate The emission rate is the capability of an object to emit or absorb energy The emission rate should be set only when the target is special material The emission rate list refers to B Common Emission Rate Setting metho...

Страница 33: ...t click to finish the area selected Figure 4 10 Temperature Area Setting Interface 4 Click Apply the message Apply success is displayed the temperature area is set successfully Delete a temperature area 5 Select an area ID 6 Click the temperature area and right click 7 Remove the tick of area ID 8 Click Apply the message Apply success is displayed the temperature area is deleted successfully Step ...

Страница 34: ...e linkage Method 1 Click left mouse button to select any time point within 0 00 24 00 from Monday to Sunday as shown in Figure 4 11 Method 2 Hold down the left mouse button drag and release mouse to select the alarm time within 0 00 24 00 from Sunday to Saturday NOTE When you select time by dragging the cursor the cursor cannot be moved out of the time area Otherwise no time can be selected Method...

Страница 35: ...ints that can t move when the environment or scenario change is bad point You can delete the bad point by bad point check function Procedure Step 1 Choose Configuration Thermal Bad Point Check The Bad Point Check page is displayed as shown in Figure 4 12 Figure 4 12 Bad Point Check Bad Point 1 Bad Point 2 Step 2 Click the white point at image click Apply to recover the bad point as shown in Figure...

Страница 36: ...t Step 3 Click Reset to return the previous settings Step 4 Click Apply The message Apply success is displayed the system saves the settings End 4 2 Visible light Web 4 2 1 Login and Logout You must use Internet Explorer 8 or a later version to access the web management system otherwise some functions may be unavailable ...

Страница 37: ...fault password is admin Please change the password to ensure system security You can change the system display language on the login page Step 3 Click login The main page is displayed End Logout To log out of the system click in the upper right corner of the main page The login page is displayed after you log out of the system 4 2 2 Main Page Layout On the main page you can view real time videos r...

Страница 38: ...ayback videos in this area NOTE Only when the SD card or NAS have videos that you can query the playback videos 3 Device configuration You can choose a menu to set device parameters including the device information audio and video streams alarm setting and privacy mask function 4 Alarm icon When the device generates an alarm the alarm icon is displayed You can click to view the alarm information N...

Страница 39: ...You can click to view the fault information 6 Change password You can click to change the password 7 Sign Out You can click to return to the login page End 4 2 3 Change the Password Description You can click to change the password for logging in to the system Procedure Step 1 Click in the upper right corner of the main page The Change Password dialog box is displayed as shown in Figure 4 16 ...

Страница 40: ...ssword and confirmation password Step 2 Click OK If the message Change own password success is displayed the password is successfully changed If the password fails to be changed the cause is displayed For example the new password length could not be less than eight Step 3 Click OK The login page is displayed End 4 2 4 Browse Video User can browse the real time video in the web management system Pr...

Страница 41: ...igure 4 17 Add a trusted site Step 2 In Internet Explorer choose Tools Internet Options Security Customer level and set Download unsigned ActiveX controls and Initialize and script ActiveX controls not marked as safe for scripting under ActiveX controls and plug ins to Enable as shown in Figure 4 18 Figure 4 18 Configure ActiveX controls and plug ins ...

Страница 42: ...lay live video and click to play video with ActiveX control to reduce latency Click the message click to play live video with ActiveX control to reduce latency jump download Adobe Flash Player Plugin control interface once downloading is complete you can watch video screen Click the message click to download the latest version of Flash Play live video jump to download ActiveX control interface onc...

Страница 43: ...e Local Network page is displayed as shown in Figure 4 19 Figure 4 19 Local Network page Step 2 Set the parameters according to Table 4 6 Table 4 6 Local network parameters Parameter Description Setting IP Protocol IPv4 is the IP protocol that uses an address length of 32 bits Setting method Select a value from the drop down list box Default value IPv4 ...

Страница 44: ...n be set as required Setting method Enter a value manually Default value 192 168 0 120 Subnet Mask Subnet mask of the network adapter Setting method Enter a value manually Default value 255 255 255 0 Default Gateway This parameter must be set if the client accesses the device through a gateway Setting method Enter a value manually Default value 192 168 0 1 Preferred DNS Server IP address of a DNS ...

Страница 45: ... the default value is 1500 Please do not change it arbitrarily Step 3 Click Apply If the message Apply succeed is displayed click Confirm The system saves the settings The message Set network parameter success Please login system again is displayed Use the new IP address to login to the web management system If the message Invalid IP Address Invalid Subnet Mask Invalid default gateway Invalid prim...

Страница 46: ... interface Table 5 1 Sensor Setting interface Parameter Description Full Screen It enlarges and displays the image in full screen Hide Info It refers to the function that hides the IP address code rate and other information of the functioning imaging device on the Client Side Note This function is only applicable to the Client Side and not for the WEB Side Sensor Configure It is used for configuri...

Страница 47: ...ion 5 2 1 Time Segment Operation procedure Step 1 Click Time Segment tag on sensor setting interface the time segment page is displayed as shown in Figure 5 2 Figure 5 2 Time Segment page Step 2 Choose Debug Mode in the lower left corner to activate the sensor setting page Step 3 Set the time segment parameters Step 4 Click Save to save the setting End 5 2 2 Image Setting Figure 5 3 shows the imag...

Страница 48: ...te display mode this range is converted into tones of grayscale for example 0 indicates fully black and 255 indicates fully white By this grayscale the temperature field of the scenario is converted into an image Actually displayed images vary with specific polarity LUT The most frequently selected modes are white hot hot objects are brighter than cold objects or black hot hot objects are darker t...

Страница 49: ...ue based on requirement Configuration method Drag the slide bar Default value 4 Mirror Allow users to select image pixel position Off images are not flipped Horizontal image is turned left right Vertical image is turned up down Horizontal vertical image is turned upside down Configuration method Select from the drop down list Default value Normal DVE Mode Select a proper DVE mode based on the cont...

Страница 50: ...Thermal Parameter Configuration Dual Vision Light Load Thermal PTZ User Manual 48 Issue V1 0 2019 04 03 Figure 5 4 FFC mode interface Table 5 3 describes the FFC mode parameters ...

Страница 51: ...y execute FFC in case that temperature change exceeds specified amount or the specified time interval expires whichever is earlier FFC interval range 5 30 min The camera temperature change amount is subject to the set value for the detector collecting internal temperature During camera startup camera temperature changes dramatically so FFC will be performed repeatedly which is a normal phenomenon ...

Страница 52: ...iguration method Drag the slide bar Default value 5 Flat Field Correction In manual or external FFC mode the camera will not automatically execute FFC in case of temperature change or the specified time interval is up In this case click Flat Field Correction End 5 2 4 Noise Reduction Figure 5 5 shows the Noise reduction interface Figure 5 5 Noise reduction interface Table 5 4 describes noise reduc...

Страница 53: ...n Method 3D NR Reduce noise of image Configuration method Select from the drop down list Default value Off 2D NR Reduce noise of image Configuration method Select from the drop down list Default value Off End 5 2 5 Adjust the Screen Figure 5 6 shows the screen adjustment interface and Table 5 5 shows the screen adjustment parameter Figure 5 6 Screen adjustment interface ...

Страница 54: ...o be identified To resolve the problem the IR image must be enhanced and preprocessed The thermal imaging camera allows an image mode to be preset according to the temperature distribution differences of a specific environment or scenario so as to highlight the object Outdoor Indoor Sky Earth Sea Sky Linear Common Custom Configurati on method Select from the drop down list Default value Sky Earth ...

Страница 55: ...ace move the cursor to the real time video page and right click on the page A shortcut menu is displayed as shown in Figure 6 1 Figure 6 1 Sensor Setting interface Step 2 Choose Sensor Configure and the Sensor Setting dialog box appears End 6 2 Sensor Setting Parameter description 6 2 1 Time Segment Operation procedure Step 1 Click Time Segment tag on sensor setting interface the time segment page...

Страница 56: ...019 04 03 Figure 6 2 Time Segment page Step 2 Choose Debug Model in the lower left corner to activate the sensor setting page Step 3 Set the time segment parameters Step 4 Click save to save the setting End 6 2 2 Image Adjust Figure 6 3 shows the Image Adjust tab page Figure 6 3 Image Adjust tab page ...

Страница 57: ...ethod Drag the slider Default value 50 Brightness It indicates the total brightness of an image As the value increases the image becomes brighter Setting method Drag the slider Default value 50 Sharpness It indicates the border sharpness of an image As the value increases the borders become clearer and the number of noise points increases Setting method Drag the slider Default value 50 Saturation ...

Страница 58: ... the working mode of a camera Outdoor It applies to outdoor scenarios Indoor It applies to indoor scenarios Configuration method Select from the drop down list Default value Outdoor Mirror It is used to select the pixel location of an image Normal The image does not flip Horizontal The image flips to the left and right Vertical The image flips up and down Horizontal and vertical The image rotates ...

Страница 59: ... Configuration Method Freeze It can be set to on or off It is used to enable or disable the image freezing function of a camera Setting method Tick the Freeze status Default value Disable 6 2 4 Exposure Figure 6 5 shows the Exposure interface Figure 6 5 Exposure interface for high speed dome Table 6 3 describes Exposure parameters ...

Страница 60: ...value Auto Max Shutter The device automatically adjusts the shutter time based on the ambient brightness The shutter time is less than or equal to the value of this parameter Setting method Select a value from the drop down list Default value 1 25 Max Gain The device automatically adjusts the gain based on the external light The gain is less than or equal to the value of this parameter Setting met...

Страница 61: ...B modes include Auto In automatic white balance WB mode the system automatically performs white balance based on the monitoring environment Tungsten Fluorescent Daylight Shadow Manual In manual WB mode you can manually select a WB mode based on the monitoring environment Setting method Select a value from the drop down list Default value Auto Red Gain It indicates the gain applied to red channels ...

Страница 62: ...s As the value increases the color temperature becomes higher This parameter is valid when Manual Mode is set to Customized Setting method Drag the slider Default value 0 6 2 6 Daynight The day night mode settings vary based on device models For details see the following sections Figure 6 7 shows the DayNight Mode interface Figure 6 7 DayNight Mode interface Table 6 5 describes DayNight Mode param...

Страница 63: ...de The image is colored and the filter is in the day state preventing infrared light from entering the sensor Night mode The image is black and white and the filter is in the night state allowing infrared light to enter the sensor Timing Set day to night time and night to day time to switch the daynight mode Setting method Select a value from the drop down list Default value Auto TRANSI D N dB It ...

Страница 64: ...auto mode The value of TRANSI D N must be greater than the value of TRANSI N D Setting method Drag the slider Default value 30 Delay s The delay time of day to night or night to day This parameter is valid in auto mode Setting method Drag the slider Default value 0 DTN Time Time of day to night Setting method Select a value from the drop down list Default value 18 00 NTD Time Time of night to day ...

Страница 65: ...m the drop down list Default value Auto Max Strength It is valid in auto noise filter mode When the parameter value is 0 the noise filter is disabled When the parameter value is greater than 0 the noise filter is enabled and the system automatically adjusts the noise filter level based on the ambient brightness without exceeding the value of this parameter Setting method Drag the slider Default va...

Страница 66: ... better image effect Setting method Tick the WDR mode and drag the slider Default value 50 HLC It provides a clearer view of an image in the highlight environment When HLC is enabled the total brightness of an image is reduced allowing you to view objects in front of the highlight Setting method Tick the HLC mode and drag the slider Default value 50 BLC It provides a clearer view of an image in th...

Страница 67: ...he image becomes clearer Setting method Tick the Defog mode and drag the slider Default value 50 6 2 9 Zoom Focus Figure 6 10 shows the zoom focus interface and Table 6 8 shows the zoom focus parameter Figure 6 10 Zoom focus interface for high speed dome Table 6 8 Zoom focus parameters description Parameter Meaning Configuration Method Digital This function enables digital zoom after an image is z...

Страница 68: ...ct from the drop down list Default value Semi automatic Auto Focus Sensitivity It indicates the sensitivity of auto focus When the sensitivity is high the camera movement is more likely to focus again at slight changes of an image Setting method Drag the slider Default value 50 The least focus distance It indicates the minimum focus distance A camera does not focus when the distance is smaller tha...

Страница 69: ... or a camera connected to an external PTZ you can control the PTZ to view Video shot in different directions In the PTZ control area you can click the eights arrow keys to move the PTZ in eight directions as shown in Figure 7 1 Figure 7 1 PTZ Control zone It may also control the iris zoom and focus of the camera lens through other buttons in the PTZ control zone Functions of each button are as sho...

Страница 70: ...iguration 7 2 1 PTZ setting Click the PTZ configuration interface displayed as shown in Figure 7 2 Figure 7 2 PTZ Configuration Through this interface you can perform the following operations Add Delete and Apply a Preset Track Scan and Tour Set and enable Idle Set the direction to due north Any direction can be set as the reference due north Configure Timer End 7 2 2 Configure and Apply Preset Yo...

Страница 71: ...nter the name of preset Step 3 Use eight arrow keys in the PTZ control area to configure a position then click to complete adding a preset Step 4 Select a Preset name from the Preset drop down list box and click to apply the preset NOTE Up to 255 Presets can be configured End 7 2 3 Configure and Apply Tracks You can record a track to allow the camera to repeatedly rotate based on the preset track ...

Страница 72: ...TZ control area to configure a track then click to complete adding a track Step 4 Select a Track name from the Track t drop down list box and click to apply the track NOTE Up to 6 Tracks can be configured End 7 2 4 Configure and Apply Scan You can configure a Scan to rotate the camera between two positions by applying the Scan Operation procedure Step 1 Click Scan tab page in the PTZ configuration...

Страница 73: ...ght arrow keys in the PTZ control area to configure two positions then click to complete adding a scan Step 4 Select a Scan name from the Scan t drop down list box and click to apply the scan End 7 2 5 Configure and Apply Tour You can configure a tour to rotate the camera between presets set by PTZ Operation procedure Step 1 Click Tour tab page in the PTZ configuration interface the add tour page ...

Страница 74: ... preset form the preset drop down list box and then input the values from Wait Time area box to set the time to stay in next position preset 0 sec 255 sec Step 7 Repeat former step until all required position presets are completed adding Step 8 Click to complete adding a tour You also can click Cancel button to quit current setting Step 9 Select a tour name and preset from the tour and preset drop...

Страница 75: ...ose preset Scan track tour and Cir Scan Step 3 Select a name form the Name drop down list box Step 4 Input a value from the Wait Time area box Step 5 Click to completed adding an idle Step 6 Click to enable idle function End 7 2 7 Configure North Operation procedure Step 1 Click North tab page in the PTZ configuration interface the north page is displayed as shown in Figure 7 8 Figure 7 8 North ...

Страница 76: ...on of true north End 7 2 8 Configure Timer Operation procedure Step 1 Click Timer tab page in the PTZ configuration interface the set timer page is displayed as shown in Figure 7 9 Figure 7 9 Set Timer Step 2 Click the Timer page is displayed as shown in Figure 7 10 Figure 7 10 Timer Step 3 Check Enable box Step 4 Select the timer mode ...

Страница 77: ...mple preset 1 Step 7 Repeat Step 5 and Step 6 to add more required time Step 8 Click to complete timer setting End 7 2 9 Configure Extension You can use extension function including lamp and brush Operation procedure Step 1 Click Extension tab page in the PTZ configuration interface the extension page is displayed as shown in Figure 7 11 Figure 7 11 Extension Step 2 Click to enable the lamp Light ...

Страница 78: ...fective Pixel 400 300 Pixel Size 17um Response Wavelength 8um 14um Thermal Sensitivity NETD 40mK F1 0 Frame Frequency 50 60Hz Focal Length 8mm 15mm 25mm 35m m 50mm 8 mm 25 mm 50 mm Focusing Mode Manual Motorized Field Angle 46 35 25 19 15 11 11 8 7 5 46 35 15 11 7 5 5 1 3 8 Aperture 1 0 Recognition Distance Body 59 110 184 257 368m 59 184 368m Recognition Distance Vehicle 180 338 564 789 1127 m 18...

Страница 79: ...ement Alarm Temperature Detection Over temperature alarm temperature difference alarm Temperature Measurement Accuracy 2 or 2 the higher one it depends emissivity distance temperature etc Detection Area Support Response Time 30ms Theory of Temperature Measurement Range 40 150 Temperature Display Mode Temperature target 5 Display absolute temperature value Temperature target 5 Display relative temp...

Страница 80: ...P Maximum User Access Amount Supports up to 10 users simultaneously access Security Password protection support for multi level user group management custom permissions a reset button Integration Features Support international standards Onvif third party agreements PAN TILT Features Rotating Speed Pan 0 01 60 s Tilt 0 01 30 s Rotation Angle Pan 0 360 continuous Tilt 90 90 Brush Support Preset Posi...

Страница 81: ...0 100Base T Audio Interface 2 input 2 output Alarm Interface 9 input 4 output CVBS Interface 2 channel Pan tilt Control interface RS485 SD card Connector Micro SD card 128 GB to the maximum physical features Power Supply DC36V Power Consumption Max 80W Operating Temperature 40 60 Operating Humidity 90 RH Protection Level IP66 Installation Mode Mounting base Dimensions 419 x 282 x 316mm L x W x H W...

Страница 82: ...d gateway setting of the camera PTZ or high speed dome is out of control The protocol bit rate or address setting of the PTZ is incorrect Modify the address of the PTZ on the web The signal cable is unconnected or not connected correctly Check the signal strength and reconnect the signal cable The measured temperatu re is not accurate The device is just powered on and the temperature of the cavity...

Страница 83: ...connected Ensure the upgrade network is connected The network setting is incorrect Check whether the network setting is correct The upgrade package is incorrect Perform the correct upgrade package again No self test no image output There is a broken line in the circuit Find breakpoints rewiring Low supply voltage Replace the power adapter to increase the output voltage Self test exception Low supp...

Страница 84: ...age instability To ensure that the input device voltage stability Can not control the lens to perform zoom and Focus action Wiring error Re connect the lens control line Circuit board lens control problems Replacement circuit board please contact after sales rework processing do not replace parts or repair Can not recall the set lens preset point DIP switch relative to the set lens preset dialing ...

Страница 85: ... emission rate is the ratio of the energy emitted by an object at a specific temperature to that emitted by an ideal radiator at the same temperature The range of emission rate value is 0 0 to 1 0 generally Materials Temperature Emissivity Gold High purity 227 4 0 0 02 Aluminum foil 27 81 0 04 Aluminum sheet 27 81 0 18 Aluminum used for families flat 23 73 0 01 Aluminum plate 98 3 purity 227 440 0...

Страница 86: ... 0 23 Brass High polish 247 476 0 03 Brass Tough rolled polished metal wire 21 70 0 04 Tinned Iron Light 0 13 Iron plate Rust eaten 20 68 0 69 Rolled steel sheet 21 71 0 66 Ferric oxide 100 212 0 74 Wrought iron 21 70 0 94 Fused iron 1299 1399 3270 2550 0 29 Copper Polished 21 117 70 242 0 02 Copper Polished not reflected 22 72 0 07 Copper Heavy oxide Board 25 77 0 78 Enamel Fuse on iron 19 66 0 9...

Страница 87: ...glazed rough 1000 1832 0 8 Carbon T carbon 0 9 ash 127 260 0 81 Concrete 0 94 Glass Glossy 22 72 0 94 Granite Surfaced 21 70 0 85 Ice 0 32 0 97 Marble I Polished grey 22 72 0 93 Asbestos board 23 74 0 96 Asbestos paper 38 100 0 93 371 700 0 95 Asphalt Paving the road 4 39 0 97 Paper Black tar 0 93 Paper White 0 95 Plastic White 0 91 ...