P.34
VALVE NO. 22
VALVE 22 IS NORMALLY OPEN. IT MAY NECESSARY TO PARTIALLY CLOSE
VALVE 22 TO PROTECT THE PUMP FROM CAVITATION BY REDUCING FLOW
RATES IN THE COLLECTOR LOOP.
PRESSURE RELIEF VALVE (COMPONENT #9)
THE PRV WILL AUTOMATICALLY OPEN AND DISCHARGE FLUID OR AIR IN
THE EVENT OF THE COLLECTOR LOOP PRESSURE EXCEEDING THE
MAXIMUM WORKING PRESSURE OF THE SYSTEM.
WHEN FILLING OR DRAINING THE SYSTEM THROUGH BD, THE PRV IS
MANUALLY OPENED OR REMOVED FROM THE COLLECTOR LOOP IN ORDER
TO ALLOW AIR TO FLOW IN OR OUT OF THE COLLECTOR LOOP.
ADDITIONAL TWO TANK SYSTEM VALVES
VALVE NO. 7
–
COLD FEED TO SOLAR TANK ISOLATION VALVE
THIS VALVE IS NORMALLY OPEN. WHEN CLOSED IN CONJUNCTION WITH
VALVE NO. 6 IT WILL ISOLATE THE SOLAR STORAGE TANK FROM THE
POTABLE WATER SYSTEM.
VALVE NO. 6
–
HOT OUTLET FROM SOLAR TANK ISOLATION VALVE
THIS VALVE IS NORMALLY OPEN. WHEN CLOSED IN CONJUNCTION WITH
VALVE NO. 7 IT WILL ISOLATE THE SOLAR STORAGE TANK FROM THE
POTABLE WATER SYSTEM.
VALVE NO. 5
–
SOLAR TANK BYPASS VALVE
THIS VALVE IS NORMALLY CLOSED. WHEN OPENED IN CONJUNCTION
WITH CLOSING VALVES NO. 6 & 7 IT WILL ALLOW COLD WATER TO
BYPASS THE SOLAR SYSTEM AND FEED DIRECTLY INTO THE AUXILLIARY
WATER HEATER.