![Sundyne LMC 341F Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/sundyne/lmc-341f/lmc-341f_instruction-and-operation-manual_1395684013.webp)
9
Baseplate Grouting
A rigid concrete mounting base is recommended for all installations. Use a non-shrink grouting to fill the
baseplate grout-fill holes. The concrete foundation should have minimum deflections and freedom from
resonant frequencies in the operating range of the equipment being supported. The stand shall be
secured in position by one inch diameter bolts. The bolts shall be installed in the foundation with sufficient
length to protrude one quarter inch above the nut. The customer shall provide a 4” x 4” x 1/4” steel plate
under each leveling screw.
BMC UNITS WITH HORIZONTAL STANDS:
The base plate should be leveled prior to grouting. Grout
shall set for the time limit as determined by the grout manufacturer.
LMC UNITS WITH VERTICAL STANDS:
The top of the stand (driver mounting surface) should be
leveled by shimming under the base prior to grouting. The channels are to be filled with grout through the
access holes. The nuts on the foundation bolts should not be tightened until the grout has set as
determined by the grout manufacturer.
Horizontal Unit Gearbox Support Bracket
A gearbox support bracket (BK01AW04) is attached to the gearbox bearing plate and provides support to
the gearbox in the horizontally mounted configuration. The bracket is a two-piece slotted hole design
attaching the two pieces to provide adjustability in the field during field installation alignment. A shim (1/4”
thickness preferred) should be placed under the bracket and alignment completed. The bracket should
then be drilled and pinned (3/8” minimum pin diameter) in two locations to prevent possibly shifting of the
bracket during operation of the unit.
Driver and Coupling
Lock out starting switch on driver prior to working on coupling, following lock-out/tag-out
procedure.
UNITS WITH VERTICAL OR HORIZONTAL STANDS -
ALIGNMENT--
If other than Sundyne supplied couplings are used, they must be flexible disc or gear type couplings
capable of tolerating parallel and angular misalignment of .005 inch maximum as well axial end play of
.060 inch maximum. Always refer to the coupling manufacturers recommendations for installation and
maintenance.
The motor and compressor coupling hubs are normally installed at the factory. For alignment
specifications, see Coupling Manufacturers Bulletin in the Final Data Package. Align the driver and
compressor after grouting and before you connect the suction and discharge piping. After you install the
piping, inspect the alignment again.
2. Lubricating Oil System
Oil Specification
The oil used in Sundyne gearboxes must meet the specifications presented in Field Engineering
Bulletin 40.2.04. In general, an ISO viscosity grade 32 oil will meet these specifications. Before using any
oil, you should verify its properties by consulting its manufacturer.
.
Содержание LMC 341F
Страница 32: ...28 Figure 5 1 Compressor Cross Section and Clearances ...
Страница 69: ...65 SINGLE SEAL ARRANGEMENT ...
Страница 70: ...66 DOUBLE SEAL ARRANGEMENT ...
Страница 71: ...67 TANDEM SEAL ARRANGEMENT ...
Страница 72: ...68 Reference D Phoenix Compressor Gearbox Cross section Drawing Phoenix Gearbox Module Drawing GB01AY01 ...
Страница 73: ...69 Phoenix Compressor Gearbox Cross Sectional View ...
Страница 74: ...70 ...
Страница 75: ...71 PHOENIX GEARBOX MODULE DRAWING GB01AY01 ...
Страница 76: ...72 ...
Страница 77: ...73 ...
Страница 78: ...74 ...
Страница 79: ...75 ...
Страница 80: ...76 ...
Страница 81: ...77 ...