background image

32

  Storage box SR 230, fig. 8  

H09-3012

  Storage bag SR 339, fig. 9  

H09-0112

  Dynamic microphone 

  SR 342, fig. 10 

T01-1213

  Voice amplifier SR 324, fig. 11  

T01-1217

  Test adapter SR 328, fig. 12 

  (SR 100, SR 90-3) 

T01-1202

  Test adapter SR 309 (SR 90-2) 

H09-1503

  ID-tag SR 368  

R09-0101

  Cleaning tissues SR 5226, 

  box of 50, fig. 13 

 H09-0401

7. Key to symbols

See user instructions

Date wheel 

Recycling symbol

CE approved by INSPEC Certification Ltd

8. Approvals 

CE/EN

The half masks SR 100, SR 90-3 and SR 90-2 

are approved in accordance with EN 140:1998. 

The EC type approval certificate has been issued 

by Notified Body 0194. For the address, see the 

reverse side of the user instructions.

 

Australian StandardsMark

The half masks SR 100, SR 90-3 and SR 90-2 are 

tested and certified to comply to AS/NZS 1716:2012. 

The StandardsMark is issued under licence by SAI 

Global Pty Limited Lic No.766 (ACN 108 716 669) 

(“SAI Global”).

Содержание H01-2012

Страница 1: ...he SR 307 compressed air attachment which then serves as a breathing apparatus with continuous flow for connection to a compressed air supply A pre filter holder is supplied Best stored in box SR 230 or storage case SR 339 P01H 2018 Rev 09 20160816 Product Model No Ordering No Half mask SR 100 S M H01 2112 SR 100 M L H01 2012 SR 100 L XL H01 2812 Product Description Technical specification A Mask ...

Страница 2: ...nt The equipment must not be used Ifyoucannotmake themaskatightfitduring the fitting test If the ambient air does not have a normal oxygen content If the pollutants are unknown or lack ad equate warning properties In environments that are Immediately Dan gerous to Life and Health IDLH With oxygen or oxygen enriched air If you find that breathing is difficult If you experience dizziness nausea or o...

Страница 3: ...in it in the space between the lower lip of the particle filter and the small tab moulded into the side of the gas filter Push firmly and twist the coin until the filter pops off Fig 1b 2 3 4 Pre filter SR 221 TheSundströmpre filterSR221isnotaprotec tive element and can never be used as primary protection or as a substitute for a particle filter It is designed to prevent nuisance particulates from...

Страница 4: ...es SR 5226 which clean and disinfect are recommended for daily care Ifthemaskisheavilysoiled useawarm up to 40 C mild soap solution and a soft brush followed by rinsing with clean water and drying in air at room temperature Proceed as follows Remove the filter the covers for the ex halation valves and the membranes the inhalationmembraneandtheheadharness Optional The harness can be washed but take...

Страница 5: ...filter attach ment of the mask Size Manufacturedintwosizes small medium S M and medium large M L Temperature range Storage temperature from 20 to 40 C at a relative humidity RH below 90 Service temperature from 10 to 55 C at a relative humidity RH below 90 Weight Small medium 165 g Medium large 175 g 6 List of parts The item numbers below refer to Fig 1 at the end of these instructions Item Part N...

Страница 6: ...ser instructions Date wheel Recycling symbol CEapprovedbyINSPECCertificationLtd 8 Approvals CE EN The half masks SR 100 SR 90 3 and SR 90 2 are approved in accordance with EN 140 1998 The EC type approval certificate has been issued by Notified Body 0194 For the address see the reverse side of the user instructions Australian StandardsMark The half masks SR 100 SR 90 3 and SR 90 2 are testedandcer...

Отзывы: