background image

Abrasi-Blast

TM

Respirator

instructions

The warranties made by MSA with respect to the product are voided if the product
is not installed, used, and serviced in accordance with the instructions in this
manual. Please protect yourself and your employees by following the instructions.
Please read and observe the WARNINGS and CAUTIONS inside. We encourage
our customers to write or call for a demonstration of this equipment prior to use
or for any additional information relative to use or repairs. Call 1-800-MSA-2222
during regular working hours.

This manual must be read carefully by all persons who have or will have the
responsibility for using or servicing the product. Like any complex piece of
equipment, the Abrasi-Blast Respirator from MSA will perform as designed only
if it is used and serviced according to the instructions. Otherwise, it could fail
to perform as designed, and persons who rely on this respirator could sustain
serious personal injury or death.

TAL 201 (L) Rev. 1

© MSA 2002

Prnt. Spec. 10000005389 (A) Mat. 818366

Doc. 818366

818366_a.qxd  1/24/02  3:18 PM  Page 1

Содержание Abrasi-Blast Series

Страница 1: ...for any additional information relative to use or repairs Call 1 800 MSA 2222 during regular working hours This manual must be read carefully by all persons who have or will have the responsibility f...

Страница 2: ...the canister 4 If using the Duo Flo combination type Abrasi Blast respirator make certain conditions of exposure are within the limits for which the device is approved or within the limits established...

Страница 3: ...pational Safety and Health NIOSH The Abrasi Blast respirator is available in the following basic configurations Configuration 1 Type CE supplied air respirator with low pressure flow control valve Co...

Страница 4: ...filter or canister The air purifying mode of operation also may be used for extended peri ods of time when an air source is not available During use the respirator remains in the supplied air mode of...

Страница 5: ...s around the tube at the first to sixth corrugation in the breathing tube b If the breathing tube is worn under the hood locate the 3 4 metal plug in the collar inside the hood and remove it by stretc...

Страница 6: ...read the socket assembly on the air supply hose 6 Connect the opposite end of the air supply hose to a respirable air source Note The pressure gauge assemblies listed below are available with fittings...

Страница 7: ...quired Turn off the air source 5 Turn the back of the hood and collar wrong side out exposing the facepiece headstraps The Velcro strip on the collar does not have to be unfastened unless a protective...

Страница 8: ...ort the facepiece by hold ing the breathing tube at the coupling nut assembly with one hand b Tighten the lower neck straps Pull the straps straight back not out c Tighten the side temple straps d Tig...

Страница 9: ...model attach the waiststrap loosely to mini mize restrictions to head movement 2 If wearing a protective cap you may wish to either remove and reverse the suspension so the bill of the cap is in the b...

Страница 10: ...oles in the lens a To open the lens housing door grasp the top corner of the plastic door and pull it away from the hood b Open the package of protec tive lens cartridges c Insert the lens cartridge i...

Страница 11: ...llow this precaution can result in serious personal injury or death Removing the Respirator 1 To remove the hood air supply system and facepiece return to fresh air and clean the outer sur faces of th...

Страница 12: ...respirator are nec essary to assure proper protection In addition the NIOSH approvals require that you regularly inspect this unit Parts found to be worn or damaged must be replaced See the parts lis...

Страница 13: ...taining rings and the lens housing assembly from the facepiece 4 Reverse the lens housing assembly so that the door hinge is at the top 5 Re install the lens retaining rings and screws 6 Perform the A...

Страница 14: ...ganic vapors Available in packages of 10 under P N 464031 P100 Cartridge approved for respirato ry protection against particulates under the 42CFR84 P100 classification 99 97 efficient against all par...

Страница 15: ...61 463938 60 80 Snap Tite Order Sep 69542 474263 468724 Waist 472666 475277 9961 463938 60 80 Snap Tite Order Sep 69542 485755 468725 Shoulder 485768 470734 9961 473741 65 85 Snap Tite Order Sep 69542...

Страница 16: ...two layers laminated 481742 12 thick untempered 3 481714 Heavy abrasive blasting two layers laminated Demand Single Valve SIZE RUBBER SMALL MEDIUM LARGE PART Model Model Model Hycar Silicone NUMBER 7...

Страница 17: ...Snap Tite Brass 474259 630307 Snap Tite Stainless Steel 474260 629672 Foster Steel 474256 55716 Hansen Brass 474258 630313 Foster Brass 474257 629981 Hansen Stainless Steel 474261 628208 Duff Norton...

Страница 18: ...815 479022 CEJN Chrome Locking 480813 479020 Replacement Replacement Pressure Demand Pressure Demand Quick Disconnect Regulator complete Regulator less AL Aluminum with male plug and plug and female B...

Страница 19: ...hat can be used are listed below Note All air supply hoses listed below are 3 8 in diameter hose ID Particles and contaminants can enter an air line respirator system when air supply hoses are discon...

Страница 20: ...TITE locking quick disconnects shown below may be used to interconnect air supply hoses To connect push the plug and socket together To sep arate the plug and socket must be pushed together and the sl...

Страница 21: ...TAL 201 L Rev 1 818366 21 Quick Disconnects 479026 Plug For C Quick Disconnect Assembly 479027 Plug For AL Quick Disconnect Assembly 818366_a qxd 1 24 02 3 18 PM Page 21...

Страница 22: ...Notes 22 TAL 201 L Rev 1 818366 818366_a qxd 1 24 02 3 18 PM Page 22...

Страница 23: ...818366_a qxd 1 24 02 3 18 PM Page 23...

Страница 24: ...818366_a qxd 1 24 02 3 18 PM Page 24...

Отзывы: