MSA Abrasi-Blast Series Скачать руководство пользователя страница 10

10

TAL 201 (L) Rev. 1 - 818366

heats of reaction with sorbent mate-
rials in the canister.

Do not use near flame or hot metal,
because hood material may burn.
The hood material is classified as
self-extinguishing as required by
Federal Standard 191, Method 5910.

Do not contact organic-based sol-
vents which may attack the hood
material, air-supply hose or other
plastic components. A partial list of
such solvents is as follows:

* Benzene
* Methyl Ethyl Ketone (MEK)
* Ethylene Dibromide
* Tetrahydrofuran (THF)
* Ethyl Acrylate
* Acetonitrile
* Isobutyl Amine
* Petroleum-Based Solvents

Return to a safe atmosphere and
discard the respirator immediately
if discoloration, crazing, blistering,
cracking or other deterioration of
the hood material, air-supply hose
or other plastic components is
observed. Failure to follow this pre-
caution can result in serious per-
sonal injury or death.

Changing Cover Lenses
The outer cover lens should be re-
moved when it gets dirty or scratched.
To change the cover lens, grasp one
of the pull-tabs on the corners of the
lens and pull straight out. The last pro-
tective lens in the cartridge has no
pull-tab. It is to be kept over the pri-
mary lens to protect its surface from
abrasive materials.

To install a protective lens
cartridge:
1. Select the proper cover lens for

the job. (Use the chart below as a
general guide to choose the car-
tridge.) A thinner cover lens may
not give satisfactory service life
because heavy abrasive may wear
holes in the lens.

a. To open the lens housing door,

grasp the top corner of the
plastic door and pull it away
from the hood.

b. Open the package of protec-

tive lens cartridges.

c. Insert the lens cartridge into the

lens housing. The cartridge can
be installed so that the pull-
tabs are either at the top or the
bottom of the lens housing.

Note: Be sure the 2 pull-tabs are not
caught in the lens door opening.

d. Close the lens housing door to

force the lens cartridge into
place. Pull on the door without
flexing the latch to be sure the
door is secured.

Select the proper cover lens for the
job. A thinner lens may not last
long, because heavy abrasives may
cause cracks in the lens.

Do not remove a lens cartridge dur-
ing abrasive work. The primary lens
may be polycarbonate and will
scratch easily. If the primary lens is
damaged, the entire lens housing
assembly must be replaced.

Do not remove the facepiece in a
contaminated area to replace the
lens cartridge. The contaminant will
remain in the surrounding air after
abrasive blasting. Return to a safe
atmosphere before removing the
respirator. Failure to observe this
precaution can cause inhalation of
the contaminant with resultant seri-
ous respiratory injury or death.

Adjusting Air Flow on Adjustable
Valve-Connectors
1. Push in on the adjusting knob,

then turn the knob.

2. Turn the knob fully clockwise (up)

for minimum air flow.

Using the Respirator

Lens

Type

Type of Service

.090”

untempered

Medium abrasive
blasting

.090”

tempered

Medium abrasive
blasting and
added protection
against glass
breakage due to
rough handling

.120”

untempered

Heavy abrasive
blasting

818366_a.qxd  1/24/02  3:18 PM  Page 10

Содержание Abrasi-Blast Series

Страница 1: ...for any additional information relative to use or repairs Call 1 800 MSA 2222 during regular working hours This manual must be read carefully by all persons who have or will have the responsibility f...

Страница 2: ...the canister 4 If using the Duo Flo combination type Abrasi Blast respirator make certain conditions of exposure are within the limits for which the device is approved or within the limits established...

Страница 3: ...pational Safety and Health NIOSH The Abrasi Blast respirator is available in the following basic configurations Configuration 1 Type CE supplied air respirator with low pressure flow control valve Co...

Страница 4: ...filter or canister The air purifying mode of operation also may be used for extended peri ods of time when an air source is not available During use the respirator remains in the supplied air mode of...

Страница 5: ...s around the tube at the first to sixth corrugation in the breathing tube b If the breathing tube is worn under the hood locate the 3 4 metal plug in the collar inside the hood and remove it by stretc...

Страница 6: ...read the socket assembly on the air supply hose 6 Connect the opposite end of the air supply hose to a respirable air source Note The pressure gauge assemblies listed below are available with fittings...

Страница 7: ...quired Turn off the air source 5 Turn the back of the hood and collar wrong side out exposing the facepiece headstraps The Velcro strip on the collar does not have to be unfastened unless a protective...

Страница 8: ...ort the facepiece by hold ing the breathing tube at the coupling nut assembly with one hand b Tighten the lower neck straps Pull the straps straight back not out c Tighten the side temple straps d Tig...

Страница 9: ...model attach the waiststrap loosely to mini mize restrictions to head movement 2 If wearing a protective cap you may wish to either remove and reverse the suspension so the bill of the cap is in the b...

Страница 10: ...oles in the lens a To open the lens housing door grasp the top corner of the plastic door and pull it away from the hood b Open the package of protec tive lens cartridges c Insert the lens cartridge i...

Страница 11: ...llow this precaution can result in serious personal injury or death Removing the Respirator 1 To remove the hood air supply system and facepiece return to fresh air and clean the outer sur faces of th...

Страница 12: ...respirator are nec essary to assure proper protection In addition the NIOSH approvals require that you regularly inspect this unit Parts found to be worn or damaged must be replaced See the parts lis...

Страница 13: ...taining rings and the lens housing assembly from the facepiece 4 Reverse the lens housing assembly so that the door hinge is at the top 5 Re install the lens retaining rings and screws 6 Perform the A...

Страница 14: ...ganic vapors Available in packages of 10 under P N 464031 P100 Cartridge approved for respirato ry protection against particulates under the 42CFR84 P100 classification 99 97 efficient against all par...

Страница 15: ...61 463938 60 80 Snap Tite Order Sep 69542 474263 468724 Waist 472666 475277 9961 463938 60 80 Snap Tite Order Sep 69542 485755 468725 Shoulder 485768 470734 9961 473741 65 85 Snap Tite Order Sep 69542...

Страница 16: ...two layers laminated 481742 12 thick untempered 3 481714 Heavy abrasive blasting two layers laminated Demand Single Valve SIZE RUBBER SMALL MEDIUM LARGE PART Model Model Model Hycar Silicone NUMBER 7...

Страница 17: ...Snap Tite Brass 474259 630307 Snap Tite Stainless Steel 474260 629672 Foster Steel 474256 55716 Hansen Brass 474258 630313 Foster Brass 474257 629981 Hansen Stainless Steel 474261 628208 Duff Norton...

Страница 18: ...815 479022 CEJN Chrome Locking 480813 479020 Replacement Replacement Pressure Demand Pressure Demand Quick Disconnect Regulator complete Regulator less AL Aluminum with male plug and plug and female B...

Страница 19: ...hat can be used are listed below Note All air supply hoses listed below are 3 8 in diameter hose ID Particles and contaminants can enter an air line respirator system when air supply hoses are discon...

Страница 20: ...TITE locking quick disconnects shown below may be used to interconnect air supply hoses To connect push the plug and socket together To sep arate the plug and socket must be pushed together and the sl...

Страница 21: ...TAL 201 L Rev 1 818366 21 Quick Disconnects 479026 Plug For C Quick Disconnect Assembly 479027 Plug For AL Quick Disconnect Assembly 818366_a qxd 1 24 02 3 18 PM Page 21...

Страница 22: ...Notes 22 TAL 201 L Rev 1 818366 818366_a qxd 1 24 02 3 18 PM Page 22...

Страница 23: ...818366_a qxd 1 24 02 3 18 PM Page 23...

Страница 24: ...818366_a qxd 1 24 02 3 18 PM Page 24...

Отзывы: