background image

Electronics Diagram 

 

or 7.5A fuse

 

Fuse 

A fuse is required in order to protect the wiring.  A 
standard automobile fuse is recommended and the 
fuse should be wired to the positive (“+”) side of the 
system close to the positive battery terminal.  For 
12V operation, use a 15A fuse, and for 24Voperation 
use a 7.5A fuse.  

 

Operating Voltage 

Fuse 

12V 15A 
24V 7.5A 

 

ATTENTION:

  If a longer connection cable is necessary, the cable cross section (or gauge) must be equal to or greater 

than the cable sizes recommended on the following table.  Be careful that the input voltage at the 
appliance does not drop below the cut-out voltage of the compressor. 

 

Cable Size  

 

12V 

Cable Length 

24V 

Cable Length 

Area AWG 

mm

Gauge m  ft. m ft. 

2.5 


10 

12 
12 
10 

2.5 


10 

13 

19.5 
32.8 


12 
20 

16 
26 
39 

65.6 

 

Low Voltage Disconnect 

The compressor electronics includes a low voltage 
disconnect feature.  If the input voltage to the 
appliance falls below 9.6V (in 12 V mode) or 21.3V 
(in 24 V mode), the compressor will shut-off.  Once 
the voltage increases above 10.9V (in 12V mode) or 
22.6V (in 24V mode), the compressor will resume 
normal operation.   

This feature is designed to protect the system battery 
from experiencing too low a depth of discharge. 
 

 

12V Operation 

24V Operation 

Cut- in 

9.6V 21.3V 

Cut - out 

10.9V 22.7V 

 

 

 

 

Rev. 05/21/08 

5

Содержание DC50

Страница 1: ...Solar Powered Refrigerator Freezer DC50 User s Guide SunDanzer 11135 Dyer Ste C El Paso TX 79934 USA 1 Rev May 21 2008 ...

Страница 2: ...BE LEFT OFF IN ITS NORMAL OPERATING POSITION FOR 2 HOURS PRIOR TO TURNING IT ON TO ALLOW THE COMPRESSOR OIL TO SETTLE IF THE APPLIANCE HAS BEEN HANDLED ON ITS SIDE OR STANDING ON END IT SHOULD BE ALLOWED TO SIT IN THE NORMAL OPERATING POSITION FOR 12 HOURS BEFORE TURNING IT ON PRIOR TO ADDING FOODSTUFF THIS APPLIANCE SHOULD BE RUN FOR AT LEAST 4 HOURS ALLOWING THE INERIOR OF THE CABINET TO COOL TH...

Страница 3: ... the cabinet Keep children away from the packaging material DANGER OF SUFFOCATION Installation This appliance is heavy Care should be taken when moving it This appliance operates on 12 or 24 Volts DC Direct Current only Under no circumstances should this appliance be directly connected to an AC Alternating Current power source Be sure that the appliance does not stand on the electrical supply cabl...

Страница 4: ...ur supports The floor must be sufficiently strong enough to support a fully loaded cabinet Use wood or metal shims to level the appliance if necessary Do not place the appliance close to heat sources heater stove boiler chimney etc and avoid prolonged exposure to direct sunlight This appliance uses the exterior walls to transfer heat from the inside of the cabinet Ensure that there is adequate spa...

Страница 5: ... voltage at the appliance does not drop below the cut out voltage of the compressor Cable Size 12V Cable Length 24V Cable Length Area AWG mm2 Gauge m ft m ft 2 5 4 6 10 12 12 10 8 2 5 4 6 10 8 13 19 5 32 8 5 8 12 20 16 26 39 65 6 Low Voltage Disconnect The compressor electronics includes a low voltage disconnect feature If the input voltage to the appliance falls below 9 6V in 12 V mode or 21 3V i...

Страница 6: ...e appliance will tend to run colder during these conditions and it may be necessary to turn the thermostat to a warmer setting towards the min If the room ambient temperature exceeds 100o F 38o C the appliance will not function as it should The appliance will tend to run warmer and it may be necessary to turn the thermostat to a colder setting towards the MAX setting Opening and Closing the Lid Th...

Страница 7: ...y the interior thoroughly Be sure to replace the plug on the defrost water drain 8 Reconnect the appliance to the electrical supply and leave running while empty for at least 2 hours allowing the interior to cool sufficiently 9 Replace the previously removed foodstuff ATTENTION A rise in temperature of frozen food products during defrosting may shorten their safe storage life CLEANING Internal Cle...

Страница 8: ...t due to Low Voltage Typically a connection is not as tight as it should be or the wire size to the compressor is too small The low voltage problem occurs at the instant of start up and is sometimes difficult to detect with a volt meter because the event is very quick 100 ms Appliance is operating but the interior is not cold Allow the appliance at least 4 hrs from initial turn on to become cold C...

Страница 9: ... WARRANTY DOES NOT APPLY TO DAMAGE OR WEAR TO THE PRODUCT CAUSED BY ACCIDENT ABUSE MISUSE NEGLECT UNAUTHORIZED ALTERATION OR REPAIR OR IF THE PRODUCT WAS NOT INSTALLED IN ACCORDANCE WITH SUNDANZER PRINTED INSTALLATION AND OPERATING INSTRUCTIONS TO OBTAIN SERVICE UNDER THIS WARRANTY THE DEFECTIVE PRODUCT MUST BE RETURNED TO SUNDANZER TOGETHER WITH A RETURN MATERIAL AUTHORIZATION RMA NUMBER ANY PROD...

Отзывы: