Electrical Wiring Instructions
IMPORTANT NOTICE:
The electrical wiring of this spa must
meet the requirements of the National Electrical Code (NEC) and
any applicable state or local codes. The electrical circuit must be
installed by a qualified electrician and approved by a local building/
electrical inspection authority.
1.
Convertible 120/240V Powered Dover Models Only:
•
120V “Plug-in” Operation:
This spa must operate on the supplied
10 foot (3m)120V GFCI cord at its original length or must be hard-
wired for longer runs.
NEVER USE AN EXTENSION CORD FOR
ANY REASON!
•
Convertible 120/240V Heater Operation: the included 120V GFCI
cord must be discarded for 240V heater operation. This spa must be
hard-wired. Supplying power to either configuration above which is
not in accordance with these instructions will void both the indepen
-
dent testing agency listing and the manufacturer’s warranty.
Export 2-Pump Certa/Chelsee/Hamilton Models (50Hz)
230V/20A*
230V/30A**
230V/40A***
Voltage:
230 VAC
230 VAC
230 VAC
# of Wires:
3
3
3
Frequency:
50Hz
50Hz
50Hz
Current Draw:
15A
23A
29A
Circuit Breaker:
20A*
30A**
40A***
* In 20A configuration, the heater
will not operate
while either jets pump is
running in high speed.
This is the factory setting
.
Note: pump 2 runs
only in high speed.
** In 30A configuration, the heater
will not operate
while both jets pumps
are running in high speed.
Note: pump 2 runs only in high speed.
*** In 40A configuration, the heater
will operate
while both jets pump are
running in high speed.
Note: pump 2 runs only in high speed.