The flexible couplings will provide means of disconnect for cleaning the impeller and also
to isolate vibration.

ELECTRICAL WIRING

The fans operate on standard 120V 60 Hz AC. All wiring must be performed in accordance
with the National Electrical Code and state and local building codes. A qualified electrician
should perform all
electrical work. Outdoor installations require the use of UL Listed watertight conduit and
power supplied from a GFCI (Ground Fault Circuit Interruptor).

ELECTRICAL CONNECTION

Connect wiring with terminal block provided, observing proper connections.

Radon Print

http://www.suncourt.com/Radon Print.html

4 of 7

1/2/2012 2:01 PM

Содержание RADON RDN04

Страница 1: ...peration of fuel burning equipment Follow safety standards codes and heating equipment manufacturer s procedures guide lines 5 There are no user serviceable parts located inside the fan unit Do NOT attempt to open this will void manufacturer s warranty Return unit to the factory with original purchase receipt for service after obtaining a Return Goods Authorization RGA 6 All wiring must be in acco...

Страница 2: ...d state speed control 1 Running watts at zero static pressure 2 Watts range at varying static pressure FAN SPECIFICATIONS Electric Motor External Rotor Ball Bearing Class B Thermally Protected Conforms To ANSI UL 705 CSA 22 2 ETL Listed Housing Material FRABS UV Protected Flame Rating UL 94V0 Housing Color White Radon Print http www suncourt com Radon Print html 2 of 7 1 2 2012 2 01 PM ...

Страница 3: ...of mounting brackets provided MOUNTING Mount the fan vertically with outlet up Insure the unit is plumb and level When mounting directly on the system piping ensure that the fan does not contact any building surface to avoid vibration noise Use the flexible couplers provided to secure the fan to the piping MOUNTING BRACKET The fan may be further secured with the mounting brackets provided Radon Pr...

Страница 4: ...e National Electrical Code and state and local building codes A qualified electrician should perform all electrical work Outdoor installations require the use of UL Listed watertight conduit and power supplied from a GFCI Ground Fault Circuit Interruptor ELECTRICAL CONNECTION Connect wiring with terminal block provided observing proper connections Radon Print http www suncourt com Radon Print html...

Страница 5: ...in any orientation that will allow water to accumulate inside the fan housing The fans are NOT suitable for underground burial Under some circumstances a condensate bypass should be installed in the outlet ducting as shown Figure 1 This may be particularly true in cold climate installations which require long lengths of outlet ducting or when the outlet ducting is likely to produce large amounts o...

Страница 6: ... more often in dusty environments Clean as necessary The unit must be disconnected from power during inspection and or cleaning SYSTEM ON INDICATOR A properly designed system should incorporate a System On Indicator to confirm system operation mode or status A manometer such as a U Tube or a vacuum alarm is recommended for this purpose SLAB COVERAGE The Suncourt Radon Fan provides coverage up to 2...

Страница 7: ...o this fan There is no implied warranty of merchantability and fitness for a particular purpose Suncourt shall not be liable for any direct indirect special incidental or consequential damages arising from or relating to the fan or the performance of it Suncourt s maximum liability shall not exceed the amount of the purchase price of the fan The sole remedy under this warranty shall be the repair ...