10 |
P a g e
THE CONTROL PANEL
The control panel is normally installed on the lip of the spa for easy and convenient access.
Within the panel housing is a 4 digit LED display used to communicate to the user spa
temperature, TOD, elapsed user time, programming, status – diagnostic and error codes and
messages. There are 2 different size panels. They are interchangeable. The 2000 Series panel
can have up to 7 keys; the 1000 Series panel will have at most 6 keys. These are membrane
type switches which when depressed generate a signal that the microprocessor will interpret
and act upon. The switches are labeled and have specific functions. They are divided into 2
groups:
Device Control Group Pump(s), Air Blower & Spa Light.
Status Control Group: Up & Down Keys & the Set Key.
Note:
If any of the keys are pressed and held closed for longer than 20 seconds, that key will
be disabled and becomes non-functional. After releasing the key, it will be re-activated after
20 seconds. This is to prevent a collapsed or defective key from locking up the system.
DEVICE CONTROL KEYS
There are up to 4 device keys, JETS, AIR, AUX & LITE. Your spa will have at least one water
pump. Optionally your spa may have an air blower, a second and/or third pump and a spa
light. It may also have a mister or a fiber optic light setup. If your spa does not have a specific
device please disregard the function of that device.
Primary Water Pump
Each spa should have at least one primary water pump which is usually a dual speed pump.
The low speed is used to filter the spa. Also while the spa is being heated or there is an error
condition, the low speed circulates the water and you will not be able to turn it off.
The
JETS
key (switch) on the control panel is a 3 position switch:
Low Pump, High Pump, Off. Each time the key is pressed, the next function is executed. If
your primary pump is a single speed pump then only the high pump will be activated. 2 LED
indicators, LO & HI inform you which speed is on.
Note:
if your spa is equipped with a circulating pump it will be used for filtration and heating
instead of the low speed pump.