Heating phase defect
HEATING PHASE DEFECT
D E L U X E / D E L U X E
PLUS
SEMI DELUXE
ECONOMY
F6
6P
X
X
X
6P
X
X
6P
The heating phase is the period from the moment the microprocessor sends the co-
rresponding signal to the dishwasher for it to begin the heating process, until it ends,
i.e. until the NTC detects the temperature selected. During this phase, if the tempera-
ture increases less than 5ºC in 10 minutes, the buzzer will sound as follows:
6 beeps
Pause 7 sec.
6 beeps
pause 7 sec………and so on, succes-
sively.
This indicates error code F6.
Obviously, this can happen either at the start of heating (i.e. it does not heat up at all),
or during the heating phase.
Important FOR USERS:
Before the ELEMENT wears
out, it is very important to advise the user to clean the dis-
hwasher FORTNIGHTLY with a special DISHWASHER
CLEANING product. The purpose of this is to clean any
residue, particularly scale, which may have formed inside
the element.
Important:
A clip-on ammeter and water temperature
sensor are essential for the correct repair of this anomaly.
Description of all Functions
I
!