More about Blood  Pressure Measurements

What is 

 Pressure?

Blood  pressure is measurement of the rate of pressure exerted by the

blood upon the walls of the blood vessels. The heart contracts and then
relaxes, producing the two levels of blood pressure. As your heart con-
tracts, a higher level  of pressuet is produced. This rate of pressure is

termed “Systolic’! As your heart relaxes, taking the blood back in, the pres-

sure is termed “Diastolic’: These measurements are  usually measured

in terms of the height of a mercury volume and referred to as MM Hg or
millimeters of mercury. These measurements are written one over the
other. Example:  “120  mmHg  (Systolic)  80   mmHg  (Distolic)".

Blood pressure varies constantly and may change according to

different activities Your  blood  pressure may change suddenly due to phys-
ical or mental anxieties, smoking, exercise, eating, stress or a number
of other conditions. Only a qualified Physician can determine whether

your blood pressure is normal.

Hypertension

 (or blood  pressure), which  is most common among adults

and the old; if left unattended, can cause health  problems  such as stroke,
heart attack, etc. Therefore, it is important to monitor blood pressure on

a continued and timely basis. Under the supervision of your physician
excellent life saving procedures exist.

IMPORTANT:  Your physician is the only qualified person to interpret your

blood pressure measurements and no device can replace
regular  medical  examinations

 by your physician. It is recom-

mended that your physician review

 your procedure

 for using

 

this blood pressure  monitor.

_,  

22.

.

             

 

 

. . . . . .       

   . .

. .

. .

Содержание 7621

Страница 1: ...Model 7621 Instruction Manual 1 ...

Страница 2: ...are utilized to insure that we provide our cus tomers with the most accurate and thoroughly tested product which can be produced As with any new product if is important that you read the instructions com pletely and familiarize yourself with the product s operation before using it If you experience any difficulty in the use of this monitor please call our toll free customer service help line 1 800...

Страница 3: ... Parts 6 Notes for Proper Measurements 8 Description of Display Marks 10 Preparation for Measurements 12 Measurements 14 16 Exhaust Velocity 18 More about Blood Pressure Measurements 20 22 24 P r e c a u t i o n s 2 6 Specifications 26 ...

Страница 4: ...Identification of Parts ...

Страница 5: ...uations of your blood pressure during the course of a day The blood pressure is usually lowest upon arising in the morning before beginning daily activities It will gradually fall again during the sleeping hours 6 Although such cases are rare for subjects having an extremely weak pulse or irregular pulse errors may result which prevent proper meas urement If such abnormal variations are noticed co...

Страница 6: ...rement was be gun but pressure was insufficient OAppears when the bat tery voltage is ex cessively low 0 Appears w h e n the blood pressure could not be measured ac curately Appears when the pulse could not ac c u r a t e l y b e m e a s u r e d 0 Flashing when exhaust speed is above 8 mm Hgls I i I j Corrective action Measurement in progress remain quiet P r e s s t h e e x h a u s t b u t t o n ...

Страница 7: ...othly and snugly Place the cuff so that the inflatable bag is centered over the brachial artery which is located approximately midway on the arm in the bend of the elbow when the palm is facing upward The bottom edge of the cuff should be positioned from 1 to 2 inches above the elbow Fasten the cuff securely Rolling up a shirt or jacket sleeve to a l l o w t h e a r m c u f f t o b e f i t t e d m...

Страница 8: ...octor s office A beeper will sound when pressure reaches 160 200 240 and 280 mmHg 4 When pressurization is completed the automatic exhaust mechanism will gradually reduce arm cuff pressure and the mark will appear on the display indicating that measurement Pressure value appearson is in progress the left and exhaust speed on the right side o ft h e display i Current Pressure xhaus t Speed g r a d ...

Страница 9: ...in the figure use a small pm or nee dle insert into tiny hole on top and flip off screw cover then proceed to Step 1 1 Apply the arm Cuff to the left arm and pressurize to the pressure 6 0 mmHg above your suspected systolic pressure Hold the area in and insert a screwdriver into groove 2 If the exhaust velocity is too fast justing screw one fraction of a turn to the left and if it is too slow turn...

Страница 10: ...etc prior to measurement can affect the results 4 The blood pressure varies constantly throughout the day Measurement should be made regularly at the same time each day 5 Do not be too impressed by the results of one measurement Keep a record of blood pressure variations Many readings tell a story 6 When making repeated measurement the arm becomes heavy with blood resulting in wide variations in m...

Страница 11: ...e varies constantly and may change according to different activities Your blood pressure may change suddenly due to phys ical or mental anxieties smoking exercise eating stress or a number of other conditions Only a qualified Physician can determine whether your blood pressure is normal Hypertension or blood pressure which is most common among adults and the old if left unattended can cause health...

Страница 12: ...pressures vary greatly both on a daily and a seasonal basis These variations are even more pronounced in hypertensepa tients Normally the blood pressure rises while at work and is at its lowest during the sleeping period The graph below illustrates the variations in blood pressure over a whole day with measurement taken every five minutes 160 r 140 E 120 f 100 I 80 60 i 40 20 PM Time AM Shown is d...

Страница 13: ...M o d e l 7 6 2 1 T y p e Oscillometric Display Digital Measurement range 20 280mmHg Pressure 40 200 pulses minute Pulse Accuracy i3mmHg or 2 whichever greater Pressure 5 Pulse Pressurization M a n u a l pressurizing Depressurization Constant Air Release Valve System Deflation Manual push button Power sources Type AAA batteries 4 Battery life Approx 6 months with 3 min usage per day operating envi...

Страница 14: ...anada Return prepaid to Solaray Division of Sunbeam Corporation Canada Limited 266 Grand River Avenue Brantford Ontario N3T 4Y4 Made in Japan CUSTOMER SERVICE HELP L I N E We want to be sure you are completely satisfied with your new pur chase If you haveany questions of experience any problems please call our toll free help line In U S A only phone 1 800 621 8854 between 8 00 a m 12 p m and 1 00 ...

Отзывы: