【M Series】Multi-turn Electric Valve Actuator
70
2021.06
Code
Warring Message
Possible Problems
Solution
28
Profibus Comm. Error
External Profibus
communication error
a.
Poor external wiring con-
nection
b.
The PCBA is broken.
c.
Control signal is not re-
ceived for more than 2
secs.
a.
Confirm if the wiring is
correct or not.
b.
Replace a new Profibus
module.
c.
Confirm if the control
signal is correct or not.
29
Spare Encoder Fault
Backup encoder fail-
ure
a.
Encoder circuit is broken.
b.
Poor external wiring con-
nection.
a.
Confirm if the wiring is
correct or not.
b.
Replace a new encoder
module.
30
Position Detect Fault
error
Operate the handwheel under
power outage to cause the po-
sition record error.
Reset the limit position. (re-
fer to 8.7.4)