CAST IRON STOVE AND BURNER SYSTEM

107281

SUN VALLEY STOVE COMPANY

For more information, visit www.desatech.com

SERVICE HINTS

When Gas Pressure is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• burner system will not produce specified

heat

• propane/LP gas supply might be low

(propane/LP units only)

When Gas Quality is Bad

• pilot will not stay lit

• burners will produce flames and soot

• burner system will backfire when lit

If you feel your gas pressure is too low or gas
quality is bad, contact your local natural or
propane/LP gas supplier.

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-DESA LOG
(1-800-337-2564).

You can also visit DESA International’s
technical service web site at

www.desatech.com

.

REPLACEMENT
PARTS

Figure 56 - Blower Wiring Diagram for Thermostat-Controlled Models

WIRING DIAGRAM

 CAUTION: Label all wires prior

to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous opera-
tion. Verify proper operation af-
ter servicing.

Note: 

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If
they can not supply original replacement
part(s), call DESA International’s Technical
Service Department at 1-800-DESA LOG
(1-800-337-2564).

When calling DESA International, have ready
• your name
• your address
• model and serial numbers of your burner

system

• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can not supply original replacement
part(s), call DESA International’s Parts De-
partment at 1-800-972-7879 for referral in-
formation.

When calling DESA International, have ready
• model number of your burner system
• the replacement part number

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115 

V.A.C.

Blower

Motor

Black 

Off

1

2

Black

Содержание MSTBVN

Страница 1: ...installationand operational procedures For as sistance or additional information consult a qualified installer ser vice agency or the gas supplier WARNING If the information in this manual is not foll...

Страница 2: ...perlyseatedandsealed If this unit is not properly installed by a quali fied service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide Poisoning Early signs of car...

Страница 3: ...gandventsvertically Heat is generated by both realistic flames and glowing embers When used without the blower accessory the stove with burner system requires no electricity making it ideal for emerge...

Страница 4: ...ined see Figures 3 and 4 4 This stove is a freestanding unit de signed to set directly on the floor If your stove is to be installed directly on carpeting vinyl tile or any combustible material other...

Страница 5: ...e Figure 7 Rest stove on drop cloth orblankettoavoidscratchingstoveedges 7 Remove remaining pallet wood at tached to bottom of stove body see Figure 8 Use an adjustable wrench to remove bolts 8 Fasten...

Страница 6: ...on a protected surface Remove the two screws that hold the front plate onto the front surround plate see Figure 14 Save these screws 15 Remove the seven screws and washers that hold the screen onto th...

Страница 7: ...nector plate over gasket and align holes Secure with hex screws provided see Figure 17 IMPORTANT Gasketandconnectingplate must not be installed until after burner sys tem has been inserted into stove...

Страница 8: ...hlocknutbypushingand turning lock nut with pliers clockwise until tight against the side of rear cover Place control knob provided onto shaft 7 Placethegreen ground wirebetweenthe bottom hole on the b...

Страница 9: ...e 8 Make sure that you don t pinch any wires during reassembly Blower Power Cord ON OFF Switch Wire Harness ON OFF Switch Figure 22 Control Valve Terminals To Control Switch INSTALLATION PRECAUTIONS C...

Страница 10: ...tion to select the correct gas vent di ameter Avoid using a larger than nec essary diameter It is very important that the venting system maintain its balance between the combus tion air intake and the...

Страница 11: ...nt ing applications NOTICE A complete chimney inspection by a qualified person should be performed Appliances using B vent connectors to vent into a masonry or factory built chimney should not exceed...

Страница 12: ...nd windows and or noticeable odors Spillage may also result in the release of carbonmonoxide acolorless odorless highly toxic gas A simple spillage test can be con ducted if spillage is suspected See...

Страница 13: ...exposed to extremely cold tem peraturesorventingofsinglewallconstruc tion loses heat needed to maintain draft massive masonry chimneys absorb needed heat Ifthefluegasescoolexcessively draft is reduced...

Страница 14: ...Valve Provided by Installer Equipment Shutoff Valve To Gas Supply Natural Figure 32 Attaching Flexible Gas Lines Together Figure 31 Gas Connection The CSA AGA design certified equipment shutoff valve...

Страница 15: ...to all gas joints Bubbles forming show a leak Correct all leaks at once Pressure Testing Burner System Gas Connections 1 Open equipment shutoff valve see Fig ure 33 2 Open propane LP supply tank valve...

Страница 16: ...ch side of the base see Figure 37 WARNING Do not connect this thermostat to a power source Electrical shock and or fire hazard will occur Figure37 BackViewofThermostatBase Feed wires through rectangul...

Страница 17: ...g Receiver Battery Clip Terminal Wires LO H I P I L O T OFF ON Figure 40 Installing Remote Receiver 2 Remove the screws from the 2 tabs at the top of the glass door while holding door securely keeping...

Страница 18: ...ury INSTALLING LOGS LAVA ROCK AND GLOWING EMBERS STOVE AND B VENT BURNER SYSTEM INSTALLATION Continued 1 2 3 4 Figure 45 Installing Log No 1 Figure 46 Installing Log No 2 Figure 47 Installing Log No 3...

Страница 19: ...push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a f...

Страница 20: ...will remain lit GHRCTA Series Operation 2b Press the AUTO ON OFF button on the hand held remote control see Figure 53 The lights to the left of the button will show AUTO ON or OFF Figure52 Settingthe...

Страница 21: ...AL BLOWER ACCESSORY Blower controls are located on the left side of the rear cover of stove from front of stove The DA3610TA thermostatically con trolled blower has an ON setting and an OFF setting Th...

Страница 22: ...WARNING Only parts sup pliedbythemanufacturershould be used when replacing broken ordamagedglassdoorpanel see ReplacementParts page26 This glass door panel is a complete unit No substitute materials m...

Страница 23: ...ot fully open 4 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located...

Страница 24: ...for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 22 or replace burner or...

Страница 25: ...l valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Burner system produces unwanted odor...

Страница 26: ...elallwiresprior to disconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswi...

Страница 27: ...epartment at 1 877 SUNVAL1 for information You canalsowritetotheaddresslistedontheback page of this manual WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 Not Shown Allows easy wall access to the operation...

Страница 28: ...UN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MSTBVN MSTBVP LO H I P I L O T OFF ON 4 4 17 18 19 21 23 1 23 4 23 2 23 3 27 4 22 10 5 11 8 1 9 25 4 13...

Страница 29: ...13 105489 01 Valve Natural 1 105489 02 Valve Propane LP 1 14 105488 01 Pilot Assembly Natural 1 105488 02 Pilot Assembly Propane LP 1 15 102445 01 Ignitor Piezo 1 16 106854 01 4 Connector Gasket 1 17...

Страница 30: ...107281 SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN SUN VALLEY STOVE MC SERIES Indicates Color Suffix Designation 1R 1C 1L 5 8 8 7 4 6 5 5 7 1 7 2 5...

Страница 31: ...lain Enamel Almond 4 Total Per Stove 1 104175 14 One Leg Porcelain Enamel Green 4 Total Per Stove 1 104175 15 One Leg Porcelain Enamel Red 4 Total Per Stove 1 6 104176 01 Leg Leveler bolt M8 x 1 25 55...

Страница 32: ...be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE D...

Отзывы: