Chapter 3
Configuring Jumper Settings
3-5
3.1.8
P10(3-4) IPMC FWE
These are reserved and should be left configured for the default setting.
3.1.9
P11(1-2) Forced-Board Enable
This jumper controls whether the switch is forced on when it is powered up, or if the
IPMI subsystem controls the power up of the switch. Forcing power to the board is
not enough for the board to boot. The board could still be held in reset. Configre P11
(3-4) jumper setting as well to bring the board out of reset.
3.1.10
P11(3-4) IPMC Board Reset
This jumper configres the IPMI to send a reset signal that will reset the entire board
TABLE 3-9
P10 (3-4) IPMC FWE Reserved Jumper Settings
P10
(3-4)
Default
Function
ON
OFF
Default
Normal operation
TABLE 3-10
P11 (1-2) Forced-Board Enable Jumper Settings
P11
(1-2)
Default
Function
ON
Force power on. Use this to run without a ShMC.
OFF
Default
IPMI controls power to the board.
TABLE 3-11
P11 (3-4) IPMC Board Reset Jumper Settings
P11
(3-4)
Default
Function
ON
IPMI subsystem cannot reset the switch. Use this to run without a
ShMC.
OFF
Default
IPMI subsystem can reset the switch and hold it in reset.
Содержание Sun Netra CP3240
Страница 3: ...Please Recycle ...
Страница 4: ......
Страница 12: ...xii Sun Netra CP3240 Switch Installation Guide September 2009 ...
Страница 14: ...xiv Sun Netra CP3240 Switch Installation Guide September 2009 ...
Страница 18: ...xviii Sun Netra CP3240 Switch Installation Guide September 2009 ...
Страница 78: ...3 8 Sun Netra CP3240 Switch Installation Guide September 2009 ...
Страница 108: ...A 4 Sun Netra CP3240 Switch Installation Guide September 2009 FIGURE A 1 PCB Dimensions ...
Страница 111: ...Appendix B Connectors B 3 B 2 Connector Locations Topside FIGURE B 1 Connector Locations Topside ...
Страница 129: ...D 6 Sun Netra CP3240 Switch Installation Guide September 2009 ...
Страница 131: ...Index 2 Sun Netra CP3240 Switch Installation Guide September 2009 ...