Sun Microsystems SUN NETRA CP3000 Скачать руководство пользователя страница 9

Preface

ix

Sun Welcomes Your Comments

Sun is interested in improving its documentation and welcomes your comments and
suggestions. You can submit your comments by going to:

http://www.sun.com/hwdocs/feedback

Please include the title and part number of your document with your feedback:

Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s
Guide

, part number 820-7175-11.

Содержание SUN NETRA CP3000

Страница 1: ...m Submit comments about this document at http www sun com hwdocs feedback Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User s Guide for the AMC 1 HDD SAS Disk Part No 82...

Страница 2: ...ans le produit qui est d crit dans ce document En particulier et ce sans limitation ces droits de propri t intellectuelle peuvent inclure un ou plus des brevets am ricains list s l adresse http www su...

Страница 3: ...1 2 Chassis Compatibility 1 2 1 1 3 Blade Server Compatibility 1 2 1 1 4 Electrical and Environmental 1 3 1 2 Unpacking 1 3 1 3 Handling AMCs 1 4 1 4 AMC Faceplate 1 5 1 5 AMC LEDs 1 6 1 6 Removing an...

Страница 4: ...9 2 Overview 2 1 2 1 Features 2 2 2 2 Key Components 2 3 2 2 1 Hard Drive Disk 2 3 2 2 2 Power Regulator 2 3 2 2 3 SAS Controller 2 4 2 2 4 Flash 2 4 2 2 5 Module Management Controller MMC 2 4 2 2 6 P...

Страница 5: ...A 1 A 1 Connector Locations and Assignments A 2 A 2 Connector Pinouts A 2 A 3 SAS Controller Ports A 4 A 4 e Keying Ports A 5 B Environment Specifications B 1 B 1 Electrical and Environmental B 2 B 1...

Страница 6: ...Mezzanine Card PCIe Hard Drive and SAS Controller User s Guide March 2010 C 4 1 EN 55022 Emissions C 4 C 4 2 EN 55024 Immunity C 4 C 5 Regulatory Information C 5 C 5 1 FCC USA C 5 C 5 2 Industry Cana...

Страница 7: ...ters do not display correctly change the character encoding in your browser to Unicode UTF 8 Typeface Meaning Examples AaBbCc123 The names of commands files and directories on screen computer output E...

Страница 8: ...ill not be responsible or liable for any actual or alleged damage or loss caused by or in connection with the use of or reliance on any such content goods or services that are available on or through...

Страница 9: ...es your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document with your feedback Sun Netra CP3000...

Страница 10: ...x Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User s Guide March 2010...

Страница 11: ...are present on the midplane Do not reach into the enclosure while the power is on Caution Static electricity can damage electronic components Wear a wrist strap grounded through one of the system s ES...

Страница 12: ...he module to determine the presence of and any limitations of chassis IPMI bus and user defined pin outs For example some chassis backplanes route certain I O pins to internal resources such as alarm...

Страница 13: ...ts are damaged notify the carrier and Sun Retain the shipping carton and packing material for inspection by the carrier Obtain authorization before returning any product to Sun Refer to the Netra CP30...

Страница 14: ...an antistatic wrist strap available in the shipkit and at electronics stores that is attached to an active electrical ground Note that a system chassis might not be grounded if it is unplugged Cautio...

Страница 15: ...point Transport an AMC in an antistatic bag 1 4 AMC Faceplate The following shows the faceplate of the Sun Netra CP3000 AMC 1 HDD SAS disk FIGURE 1 1 AMC 1 HDD SAS Disk Faceplate Note The AMC is avail...

Страница 16: ...tail the different hot swap BLUE LED states TABLE 1 1 AMC Status LEDs LED Color State Description Hot swap Blue On Management power is available to the AMC and the AMC can safely be extracted Off The...

Страница 17: ...activating 2 Blinking from solid M2 Activation Request The bottom latch is closed or activation lock bit has been cleared The IPMI microcontroller has requested permission to boot the payload from the...

Страница 18: ...ade server use the following instructions If you want to remove the blade server with the AMC installed see the next section Section 1 6 2 Removing a Blade Server and AMC on page 1 12 Caution Before r...

Страница 19: ...igure the Shelf to allow deactivation via latch opening or deactivate by other methods 4 For the AMC initiate the hot swap deactivation sequence by pulling the injector ejector latch out half way FIGU...

Страница 20: ...the module is not in the hot swap state and the shelf manager communicates with the MMC This position is for normal operation 2 Half Way HW When in the HW position the hot swap sequence is initiated...

Страница 21: ...Started 1 11 7 Remove the AMC FIGURE 1 3 Removing the AMC 8 Replace the AMC with another AMC FIGURE 1 7 or install a filler panel Note Be sure to follow handling instructions See Section 1 3 Handling...

Страница 22: ...nd installed AMC For additional information refer to your blade server documentation Caution Before removing a blade server and AMC read all cautions warnings and instructions presented earlier in thi...

Страница 23: ...er panel to maintain the enclosures shielding and cooling performance Caution Failure to cover all open slots with filler panels can negatively impact the cooling of the system 1 6 3 Installing an AMC...

Страница 24: ...instructions See Section 1 2 Unpacking on page 1 3 and Section 1 3 Handling AMCs on page 1 4 FIGURE 1 5 Sample Top View Note The illustration shows a sample of the top view for a 146GB AMC If your AM...

Страница 25: ...swap state and the shelf manager communicates with the MMC This position is for normal operation 2 Half Way HW When in the HW position the hot swap sequence is initiated The MMC sends a hot swap event...

Страница 26: ...ight be helpful to look into the enclosure to verify correct alignment of the rails in the guides Caution Do not force the AMC into the site If it does not fit properly check to ensure that you have t...

Страница 27: ...in fully If system power is on and AMC is installed properly the AMC board Hot Swap LED lights up The Hot Swap LED blinks for several seconds then goes off If the Hot Swap LED does not go off after s...

Страница 28: ...abling and Disabling SAS Ports As shipped from the factory the AMC 1 HDD SAS disk will not drive AMC channel ports unless specifically enabled You can individually enable or disable the ports using ls...

Страница 29: ...of the AMC Only advanced users who fully understand the technical implications should modify parameters A full description of parameters and functions is in LSIUtil Configuration Utility User s Guide...

Страница 30: ...1 20 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User s Guide March 2010...

Страница 31: ...features of the AMC against the needs of a specific application This chapter contains the following topics Section 2 1 Features on page 2 2 Section 2 2 Key Components on page 2 3 Section 2 3 Faceplate...

Страница 32: ...pport a combination of AMC 1 PCI Express and AMC 3 SAS storage signaling The AMC 1 HDD SAS disk includes a modular management controller MMC This AMC is designed for use in a wide variety of next gene...

Страница 33: ...isk The Sun Netra CP3000 AMC 1 HDD SAS disk provides a single SAS hard drive with various capacity options available When you order the product choose the part number corresponding to the capacity in...

Страница 34: ...is preloaded with firmware that manages the protocols necessary to communicate with SAS and SATA target devices The flash device contains BIOS and F code to support boot from disk operations 2 2 5 Mod...

Страница 35: ...complete connector descriptions and pin outs 2 2 7 LEDs The AMC 1 HDD SAS disk has three LEDs See the next section for a detailed description of the LEDs 2 3 Faceplate and LEDs The faceplate of the AM...

Страница 36: ...ower not detected Off No module fault 12V payload power is being supplied to board 2 OK Green On Module in service 12V payload power is being supplied to board Off 12V payload power is not detected 3...

Страница 37: ...dvanced Mezzanine Card PCIe Hard Drive and SAS Controller documentation set or on the web site contact your local Sun Services representative This hardware carries a one year return to depot warranty...

Страница 38: ...code FIGURE 2 4 2 6 Part Number Serial Number and Revision Number Identification The Sun Netra CP3000 AMC 1 HDD SAS disk part number serial number and revision can be found on labels located on the c...

Страница 39: ...disk drive capacity Rzz Assembly Revision Refer to Bill Of Material where zz is a numeric revision 2 Sub Assembly Number P N sub assembly Part Number 600 05101x 3 Serial Number S N Format AAA Assembly...

Страница 40: ...require regulation upon disposal Please dispose of this product in accordance with local rules and regulations For disposal or recycling information please contact your local authorities or the Electr...

Страница 41: ...the carrier board and manages communication between the AMC 1 HDD SAS disk and management controllers on the carrier board and system level Board voltages temperature and hot swap handle status are al...

Страница 42: ...read data collected by the IPMI controller and transmit it to the shelf management controller ShMC through the IPMB 0 The IPMB is routed through the AMC connector to the host carrier blade and backpl...

Страница 43: ...13 S E 2Bh Optional Get Sensor Reading 29 14 S E 2Dh Mandatory FRU Device Commands Get FRU Inventory Area Info 28 1 Storage 10h Mandatory Read FRU Data 28 2 Storage 11h Mandatory Write FRU Data 28 3 S...

Страница 44: ...D SAS disk includes additional FRU records as defined in the PICMG 2 9 specification 1 Manufacturing time is defined as minutes since January 1 1996 in the IPMI FRU specification 2 Serial Number forma...

Страница 45: ...amically created by the shelf manager and might not always start at index zero 0 TABLE 3 3 Threshold Sensors Sensor Name Type Description Units Lower Thresholds Minor Critical Non recoverable Upper Th...

Страница 46: ...e March 2010 3 5 Firmware and Software Upgrades For up to date instructions on upgrading the firmware and software refer to the following documentation Sun Netra CP3000 Advanced Mezzanine Card PCIe Ha...

Страница 47: ...the Extensible Firmware Interface EFI Boot Services Driver This chapter contains the following topics Section 4 1 Configuration Tools on page 4 2 Section 4 2 Boot BIOS Utility on page 4 2 Section 4 3...

Страница 48: ...AMC 4 2 Boot BIOS Utility The Boot BIOS utility allows you to change the default factory configuration of the AMC The utility is stored in a flash device located on the AMC module The sections that fo...

Страница 49: ...ng the Boot BIOS Utility Note Not all devices detected by the utility can be controlled by the BIOS Devices such as tape drives and scanners require loading a device driver specific to that peripheral...

Страница 50: ...all the AMC SAS modules visible in the system with PCI Express PCIe identification information 3 Use the arrow keys to highlight the AMC module you want to configure 4 Press ENTER to display the next...

Страница 51: ...the arrow keys select the item of interest 6 Press ENTER to display the next screen 4 3 OpenBoot BIOS For information about the OpenBoot BIOS refer to the Sun Solaris OS and SPARC documentation The do...

Страница 52: ...e with ATCA blades that feature Intel IA64 processors Additional information is available at http www lsi com 4 5 Enabling and Disabling Channel Ports As shipped from the factory the AMC 1 HDD SAS dis...

Страница 53: ...pplication specific devices A brief description of each connector and port is given and a detailed description and pinout given for each connector This appendix contains the following topics Section A...

Страница 54: ...AMC 1 HDD SAS disk is listed in the following table Callout Port Function 1 2 AMC 3 Serial Storage Port 2 2 3 AMC 3 Serial Storage Port 3 3 4 AMC 1 PCI Express lane 0 4 5 AMC 1 PCI Express lane 1 5 6...

Страница 55: ...156 No Connect 22 GND 67 GND 112 No Connect 157 No Connect 23 PORT1_PRX0_P 68 PCIe_RX3_P 113 GND 158 GND 24 PORT1_PRX0_N 69 PCIe_RX3_N 114 No Connect 159 No Connect 25 GND 70 GND 115 No Connect 160 N...

Страница 56: ...s with systems that have other initiators driving these AMC ports 40 GND 85 GND 130 No Connect 41 AMC_ENABLE_L 86 GND 131 GND 42 12V 87 No Connect 132 No Connect 43 GND 88 No Connect 133 No Connect 44...

Страница 57: ...on are defined in the following table TABLE 0 1 AMC e Keying Port Assignments Port Port Name Link Type AMC Port Map Region 0 Unused 1 Unused 2 Channel 0 Link type 7 AMC 3 storage Link type extension 2...

Страница 58: ...A 6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User s Guide March 2010...

Страница 59: ...lectrical environmental and mechanical specifications It includes illustrations of the board dimensions This appendix contains the following topics Section B 1 Electrical and Environmental on page B 2...

Страница 60: ...ronmental The environmental values are listed in the following table TABLE B 1 Electrical Specifications SUPPLY SAS Max Management power Less than 100 mA 12V spin up less than 8 secs 1 5A 18W 12V norm...

Страница 61: ...10 025 rpm Seek time avg Read write 4 5 m s typical Seek time max Read write 9 0m s typical Interface SAS 3 0 Gb MTBF See the following table TABLE B 3 MTBF Values by Temperature Temperature MTBF 0 C...

Страница 62: ...sue 1 The prediction assumed 25 Celsius operating temperature with 100 percent duty cycle in a ground benign controlled environment MTBF 630 000 hours One year limited warranty Payload voltage 12V 0 V...

Страница 63: ...to the component height requirements of a mid size module and can be configured as a full size module PCI Express x4 connections are made through the AMC edge fingers The AMC 1 HDD SAS disk conforms...

Страница 64: ...B 6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User s Guide March 2010...

Страница 65: ...connected to earth ground providing the path for connecting shields to earth ground Front panel screws properly tightened For minimum RF emissions it is essential that these conditions be implemented...

Страница 66: ...elcordia GR 63 Issue 3 March 2006 Network Equipment Building System NEBS Requirements Physical Protection Telcordia GR 1089 Issue 4 June 2006 Electromagnetic Compatibility And Electrical Safety Generi...

Страница 67: ...were considered CENELEC Common Modifications Annex ZA AU Australia and New Zealand CH Switzerland DE Germany DK Denmark ES Spain FI Finland GB United Kingdom IE Ireland KR Korea NO Norway SE Sweden Ch...

Страница 68: ...s and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment C 4 2 EN 55024 Immunity Telcordia GR 1089 CORE EMC For Network Telecommunication Equipment Issue 4...

Страница 69: ...ential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense This AMC complies with Part 15 of the FCC Rules Operat...

Страница 70: ...CIe Hard Drive and SAS Controller User s Guide March 2010 1 Ce dispositif peut ne pas causer l interf rence nocive 2 Ce dispositif doit accepter n importe quelle interf rence re ue y compris l interf...

Страница 71: ...or Electromagnetic Compatibility C 2 electrical and environmental 1 3 electrical environmental and mechanical specifications B 1 Electronic Industries Alliance 2 10 energy hazards 1 1 F faceplate 1 5...

Страница 72: ...4 P part number 2 8 payload voltage B 4 PHY resetting 3 2 physical shock 1 3 pinouts A 2 R related documentation viii reliability B 4 removing a switch and installed AMC 1 12 removing an AMC 1 8 remo...

Отзывы: