Sun Fire V490 Server Setup and Rackmounting Guide • August 2004
9. Connect the outlet plug of each power cord to the power sequencer in the cabinet,
or to a grounded AC power outlet.
Note –
Each outlet must connect the server to a 15A circuit for North America and
Japan, and to a 10A circuit for Europe. Consult your local electrical codes for any
additional requirements. See the instructions provide with your cabinet for
information about the power sequencer.
Note –
For increased server redundancy, connect the power cords to separate
circuits.
10. Plug in the TPE cable to the RJ-45 outlet to connect to your Ethernet network.
See your network administrator if you need more information about how to connect
to your network.
11. Secure the server to the front vertical mounting rails using either four M6 screws
or four 10-32 screws.
Restore the Cabinet
See the instructions provided with your cabinet to complete these steps.
1. Retract the cabinet’s anti-tip legs, if applicable.
2. Replace the side panels, if applicable.
3. Replace the front and back doors, if applicable.
What Next
The next step is to set up a system console, power on the server, and install the
Solaris Operating System. See Part One of the
Sun Fire V490 Server Administration
Guide
or the
Sun Fire V490 Quick Start Guide
to continue the installation procedure.
Содержание Sun Fire V490
Страница 6: ...vi Sun Fire V490 Server Setup and Rackmounting Guide August 2004...
Страница 10: ...x Sun Fire V490 Server Setup and Rackmounting Guide August 2004...
Страница 30: ...20 Sun Fire V490 Server Setup and Rackmounting Guide August 2004...
Страница 38: ...28 Sun Fire V490 Server Setup and Rackmounting Guide August 2004...
Страница 59: ...Chapter 3 Setup Procedures 49 Allow slack Velcro straps...