Chapter 1
Installing a Sun Fire V490 Server Into a 4-Post Cabinet
15
6. Use the slide assembly spacer to make sure that the slide assemblies are evenly
spaced and aligned correctly.
The slide assembly spacer is included in the rack kit.
a. Place the slide assembly spacer over the left and right slide assemblies at the
front of the rack.
The slots on the slide assembly spacer should fit evenly over the rails.
b. With the slide assembly spacer in place, fully tighten the front bracket screws.
c. Place the slide assembly spacer over the left and right slide assemblies at the
back of the rack.
d. With the slide assembly spacer in place, fully tighten the back bracket screws.
M6
10-32
Fully
tighten
Slide assembly spacer